Inspection history · 46
19 March 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7895328
11 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7194606
5 May 2010
Administration
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3731364
2 May 2010
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3885591
6 April 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3727510
16 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3364183
11 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2906151
7 December 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2836206
7 December 2006
Uninspected Other
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2836367
2 December 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2838781
14 September 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2778525
1 July 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2699877
26 January 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2573750
12 January 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2273778
27 July 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2147053
27 July 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2147192
30 June 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2148328
26 May 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2097995
24 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2012324
9 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1982310
15 December 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1964433
2 June 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1808028
21 May 2003
Administrative Inspection · Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1798358
13 May 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1792455
8 May 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1807743
18 November 2002
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 1707629
22 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1495492
22 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1495634
22 February 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1495649
11 April 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276757
25 December 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 96921
25 August 1999
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1511181
21 April 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1123850
6 March 1998
Uninspected Towing Vessel
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 784879
31 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 43013
3 February 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 134537
25 November 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 758646
17 October 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 817
17 October 1996
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 208387
29 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 221210
21 November 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 666334
30 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 44155
30 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 666335
31 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666336
7 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 21984
9 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309814
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 May 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date the action for this deficiency shall be changed to a 60(Rectify deficiencies prior to movement) and they vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 August 2021
Resolution: Vessel is a rec vessel and not subject to Sub M requirements.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 7 December 2006
Resolved
Starboard engine did not have a guard protecting the forward shaft cap, spinning freely.
Condition: Improper Installation
Due 22 January 2007
Resolved 5 May 2010
Resolution: Cleared during previous inspection.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 September 2006
Resolved
Upon doing an MTSA Verification the tug was found to have an inoperable radar device. When radar was turned on "fuzzy" lines would appear. Radar could not be seen and the lines would continuously flicker on the screen. This created a safety hazard because boat could not operate in bad weather conditions.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 15 September 2006
Resolution: 15Sep06: Received technician''s report attesting to the proper operation of the radar. The Captain of the Port Order was cancelled.
Engineering › Fuel Oil Service System › Tank
Issued 21 May 2003
Resolved
Repair leaks in fuel oil tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 21 May 2003
Resolution: Rcvd surveyor''s report attesting to the replacement of one 18" x 22'' (3/8" thick) plate on fuel oil tank.
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2003
Resolved
Provide gauge thickness readings of bottom plating in way of fwd fuel oil tank.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 21 May 2003
Resolution: Rcvd surveyor''s report attesting to the replacement of one 36" x 20'' bottom plating (3/8" thick) in way of fuel oil tank.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 May 2003
Resolved
Repair/replace watertight door handle, install screen over potable water tank, & install spill rail on stove top.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 21 May 2003
Resolution: Rcvd surveyor''s report attesting to the correction of all above items.
Documentation
Issued 6 March 1998
Resolved
VESSEL MUST OBTAIN MSD CERTIFICATION FOR TYPE II SEWAGE SYSTEM
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 6 March 1998
Resolved
REPAIR OR REPLACE SEWAGE VENT PIPING.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998