Records from 1996 to 2026. Most recent: inspection, 29 May 2026.
Documentation record
Registered dimensions (L × B × D)66.4 ft × 24.0 ft × 10.2 ft
Registered tonnagegross 165 / net 112
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUDSON SHIPBUILDERS INC · PASCAGOULA, MS, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEAST DUBUQUE, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it112 - Regulatory (Subpart C or D), Net Ton
165 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
29 May 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8395741
27 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8101498
14 May 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7912323
18 February 2020
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6913065
10 November 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5023577
21 August 2012
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4424603
24 October 2011
Administration · MTSA Verification · Industry Initiated Exam · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4175730
30 March 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3992784
17 January 2009
Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3395875
3 April 2007
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2900640
3 April 2007
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2900642
15 February 2007
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2874424
2 June 2005
MTSA Verification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2377196
12 January 2005
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2329574
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984468
24 July 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 760675
23 July 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 210941
21 June 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 291280
21 October 1996
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 13513
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 May 2026
No resolution recorded
No person may operate a non-oceangoing ship of 100 gross tons and above that is fitted with main or auxiliary machinery spaces in the navigable waters of the United States unless:(1) The ship has at least one pump installed to discharge oily mixtures through a fixed piping system to a reception facility;(2) The piping system required by this section has at least one outlet that is accessible from the weather deck;(3) Each outlet required by this section has a shore connection that is compatible with reception facilities in the ship's area of operation; and (4) The ship has a stop valve for each outlet required by this section. Vessel does not have fixed oily mixture discharge system installed on board. 33 CFR 155.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2029
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 29 May 2026
No resolution recorded
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Valve for main diesel tanks is not in the correct location directly outside tank. 46 CFR 143.260(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2029
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 May 2026
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station. Vessel is not fitted with magnetic compass or swing meter. 46 CFR 140.725(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 18 June 2026
Resolution: Installed compass
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 29 May 2026
Resolved
The instructions supplied by the manufacturer must contain directions for each of the following: Installation of a vent or flue pipe. Ventilation for MSD onboard vessel is not in accordance with manufacturers instructions. 33 CFR 159.57(a)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 18 June 2026
Resolution: Properly installed vent line.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 May 2026
Resolved
The portable fire pump must be self-priming and power-driven, with:(1) A minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge; Portable fire pump on board does not have installed gauge at discharge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 18 June 2026
Resolution: Installed pressure gauge
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The Stbd. hydraulic steering hoses/hard lines are resting on the STBD steering ram. Mount/secure hydraulic lines to clear the steering ram to prevent chaffing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 20 June 2025
Resolution: vessel rep provided picture of supported lines
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2025
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The aft engine room center breaker panel cover was replaced and is missing the proper labeling. Label breakers with a description of the loads they serve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 24 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2024
Resolved
Each remote valve control must be marked in clearly legible letters, at least one inch high, indicating the purpose of the valve and the way to operate it. The vessel's remote fuel pulls were not marked. Mark remote fuel pulls IAW the regulation and provide evidence to the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 6 August 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 18 June 2024
Resolved
Vessel is required to have applicable transfer procedures due to oil carrying capacity. Vessel did not have applicable procedures. Provide applicable transfer procedures and subsequent line diagram for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 6 August 2024