PERSEVERE is a 1980 towing vessel. The Coast Guard has recorded 19 inspections since 1996, most recently in May 2026, along with 9 deficiencies — 2 with no resolution recorded — and 3 casualty investigations between 2005 and 2011.
Records from 1996 to 2026. Most recent: inspection, 29 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)66.4 ft × 24.0 ft × 10.2 ft
Registered tonnagegross 165 / net 112
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHUDSON SHIPBUILDERS INC · PASCAGOULA, MS, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portEAST DUBUQUE, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it112 - Regulatory (Subpart C or D), Net Ton 165 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 May 2026No resolution recorded
No person may operate a non-oceangoing ship of 100 gross tons and above that is fitted with main or auxiliary machinery spaces in the navigable waters of the United States unless:(1) The ship has at least one pump installed to discharge oily mixtures through a fixed piping system to a reception facility;(2) The piping system required by this section has at least one outlet that is accessible from the weather deck;(3) Each outlet required by this section has a shore connection that is compatible with reception facilities in the ship's area of operation; and (4) The ship has a stop valve for each outlet required by this section. Vessel does not have fixed oily mixture discharge system installed on board. 33 CFR 155.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2029
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 29 May 2026No resolution recorded
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside of the fuel oil supply tank. Valve for main diesel tanks is not in the correct location directly outside tank. 46 CFR 143.260(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2029
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 May 2026Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station. Vessel is not fitted with magnetic compass or swing meter. 46 CFR 140.725(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 18 June 2026
Resolution: Installed compass
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 29 May 2026Resolved
The instructions supplied by the manufacturer must contain directions for each of the following: Installation of a vent or flue pipe. Ventilation for MSD onboard vessel is not in accordance with manufacturers instructions. 33 CFR 159.57(a)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 18 June 2026
Resolution: Properly installed vent line.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 May 2026Resolved
The portable fire pump must be self-priming and power-driven, with:(1) A minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge; Portable fire pump on board does not have installed gauge at discharge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2026
Resolved 18 June 2026
Resolution: Installed pressure gauge
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2025Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. The Stbd. hydraulic steering hoses/hard lines are resting on the STBD steering ram. Mount/secure hydraulic lines to clear the steering ram to prevent chaffing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 20 June 2025
Resolution: vessel rep provided picture of supported lines
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2025Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The aft engine room center breaker panel cover was replaced and is missing the proper labeling. Label breakers with a description of the loads they serve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2025
Resolved 24 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2024Resolved
Each remote valve control must be marked in clearly legible letters, at least one inch high, indicating the purpose of the valve and the way to operate it. The vessel's remote fuel pulls were not marked. Mark remote fuel pulls IAW the regulation and provide evidence to the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 6 August 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 18 June 2024Resolved
Vessel is required to have applicable transfer procedures due to oil carrying capacity. Vessel did not have applicable procedures. Provide applicable transfer procedures and subsequent line diagram for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 6 August 2024
12 January 2005Routine · role: Transiting Vicinity of Primary Subject · activity 2329574
15 February 2007Routine · role: Sighted in Area · activity 2874424
30 March 2011Routine · role: Transiting Vicinity of Primary Subject · activity 3992784
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
BELGIAN (2005–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.