Records from 1992 to 2026. Most recent: inspection, 9 July 2026.
Documentation record
Registered dimensions (L × B × D)70.5 ft × 30.0 ft × 9.6 ft
Registered tonnagegross 209 / net 142
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHERIOT-MODEC INDUSTRIES · GOLDEN MEADOW, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it142 - Regulatory (Subpart C or D), Net Ton
209 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
9 July 2026
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8433889
23 April 2025
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8117659
13 February 2025
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8079267
27 November 2024
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8037974
30 August 2024
Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7992653
30 August 2024
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7996022
26 June 2024
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7943021
9 March 2024
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7877077
9 March 2024
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7877340
12 February 2021
Initial Certification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7167031
18 November 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7100937
11 December 2017
MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6322915
13 April 2017
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6127828
8 December 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5779438
30 November 2015
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5772416
30 January 2014
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4791518
10 April 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3987163
30 March 2011
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3992784
6 December 2010
DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3906016
18 January 2009
Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3396794
19 May 2005
MTSA Verification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2362501
12 January 2005
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2329574
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1984418
8 August 2003
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1870237
20 June 2002
Annual Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1652373
21 June 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 291278
20 April 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 215697
1 February 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 176748
14 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659137
26 October 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 421936
24 October 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 169227
9 September 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 97751
6 August 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 84305
6 August 1998
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 179229
10 February 1998
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 28245
18 January 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 48746
18 January 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 100393
17 November 1995
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 646133
29 June 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 646116
25 June 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 30008
6 June 1994
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 75330
10 March 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 117687
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 April 2025
Resolved
Vessel machinery shall be maintained to ensure safety of vessel/crew. Vessel lost starboard flanking rudder. Install new rudder, demonstrate proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 April 2025
Resolution: Received TPO Close-Out Report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel has a loss of propulsion on the port shaft. Determine cause of issue and repair to the satisfaction of an attending Marine Inspector. The vessels TPO has the option to clear this deficiency with notification to the local OCMI within 72-hours in accordance with CG-CVC Policy Letter 17-10.
46 CFR 143.205(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2024
Resolution: Received objective evidence from TPO
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 June 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. 2 pin holes found in stern void causing significant flooding. Repair IAW company TSMS. The vessel's TPO has the option to clear this deficiency in accordance with CG-CVC Policy Letter 17-10. Objective evidence attesting to root cause & satisfactory repairs must be submitted to local OCMI within 72-hours.
46CFR140.205
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2024
Resolution: Received objective evidence of satisfactory repairs.
Navigation
Issued 26 October 1998
Resolved
Forward masthead light was inop.
Condition: Unknown
Due 26 November 1998
Resolved 13 November 1998
Unknown
Issued 26 October 1998
Resolved
Designation of PIC not adequate.
Condition: Unknown
Due 26 November 1998
Resolved 13 November 1998