MAURY USCG vessel records
← All vessels

PIONEER

Built
1981
Last inspected
12 December 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 12 December 2024
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 17 calendar years (1992–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL8701
194598
Flag
UNITED STATES
Maury page id
psix-194598

Documentation record

Registered dimensions (L × B × D)62.5 ft × 24.0 ft × 9.5 ft
Registered tonnagegross 133 / net 91
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRAFTON, IL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationValid · issued 21 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Net Ton
133 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 25 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 13 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

Inspection history · 25

12 December 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8047097
14 December 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7830418
12 January 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7620480
12 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7376317
25 March 2021 Examination of Repairs · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7162823
18 November 2020 Special Consideration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7097809
13 October 2020 Deficiency Check · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6970938
20 April 2018 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6416212
8 June 2017 Administrative Inspection · Uninspected Other · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6195965
17 January 2017 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6077500
16 December 2016 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6065879
9 January 2013 Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4513528
28 April 2009 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3468174
14 April 2009 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3454556
14 April 2009 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3584970
23 June 2008 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3246355
4 April 2007 Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2901548
11 March 2007 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2886200
11 March 2007 Uninspected Other
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2886449
29 June 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2196540
3 January 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 1992830
29 August 2002 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1677730
23 June 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 30028
8 January 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 43988
18 August 1992 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 140796

Deficiency record · 50

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 January 2023 Resolved
Alarms must be visible and audible at each operating station. No visible or audible alarms sounded when testing engine room high bilge levels alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2023
Resolved 16 January 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Battery below pilot house not secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2023
Resolved 18 January 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 January 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Two (02) dead end wires with bare wire at ends located under bridge console, port side of operator’s station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2023
Resolved 20 January 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 12 January 2023 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. According to vessel logs, vessel operated on January 9th, 10th, and 11th. However, there was no records of the navigation assessment for these dates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2023
Resolved 20 January 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 January 2023 Resolved
All crewmembers {Master(s) and deckhand(s)} must be provided with health and safety information and training, and refresher training must be repeated annually. All training must be documented in owner or managing operator's records. Inspection found no documentation of annual refresher training having been completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2023
Resolved 20 January 2023
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 January 2022 Resolved
Safety orientation records are required (for the particular towing vessel) which show the date, a general description, the name of the provider, and the name of the individual receiving the safety orientation. There was no record of vessel master's safety orientation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 1 February 2022
Resolution: Records provided which documented that the vessel master had recieved safety orientation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 January 2022 Resolved
Fire detection system required to be tested and inspected IAW manufacturer's approved design manual (as per 46 CFR 142.330) at least once every 12 months. System not inspected by certified individual within the last 12 months.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2022
Resolution: Technician's report provided by vessel operated showing system properly serviced by certified individual.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 January 2022 Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel to a propulsion engine. Fuel shut off valve failed to close when crew attempted to activate remotely. CORRECTED by end of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 January 2022 Resolved
A 40-B portable fire extinguisher must be located near the flammable/combustible storage cabinet. A portable fire extinguisher with at least a 40-B rating was not located near the cabinet. CORRECTED.
Action required: 10 - Deficiency Rectified
Resolved 12 January 2022
Resolution: A properly sized portable fire extinguisher was mounted near the cabinet.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 January 2022 Resolved
Lifebuoys must be fitted with grab line, be marked with the vessel's name, have appliances attached around body, and one must not have a life line attached. One lifebuoy had damaged grab line (CORRECTED). One lifebuoy needed to be marked with the vessel's name. One lifebuoy had appliance attached to grab line. All lifebuoys were fitted with lifelines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 1 February 2022
Resolution: Vessel's life ring properly marked with vessel's name and not fitted with grab line (as required).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2022 Resolved
Electrical systems and equipment must minimize fire and shock hazards. Electrical junction box (located on superstructure bulkhead adjacent to port generator) was open, contained dead-end wires, and had an unused opening (not plugged) at bottom. In addition, port generator battery box lid was broken, exposing battery terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2022
Resolved 1 February 2022
Resolution: Electrical equipment exposing hazards repaired; eliminating hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 January 2022 Resolved
Electrical systems and equipment must minimize fire and shock hazards. Shore tie cable plug was damaged; Shore tie required to be repaired prior to usage.
Action required: 705 - Other - as specified
Resolved 1 February 2022
Resolution: Shore tie cable plug replaced; eliminating hazard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 January 2022 Resolved
Essential systems are required to be equipped with gauges at the machinery location. Port generator RPM gauge operated intermittently. Starboard main diesel engine oil pressure gauge was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 1 February 2022
Resolution: All required gauges on port generator and starboard main engine functioned as designed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 January 2022 Resolved
Health and safety information training, required to be repeated annually (over time, or in one setting) and required to be given to new crewmembers within 5 days of employment, must be documented in owner's, or managing operator's, records. There was no record of initial training for vessel master or refresher training for crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 1 February 2022
Resolution: Records provided which documented health and safety ptraining for the crew and vessel master.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 March 2021 Resolved
Hull fractured in vicinity of fuel tanks and repaired prior to notification to OCMI. Provide objective evidence of acceptable hull repair (ship yard or surveyor's report of damage description including location, effected repair, and testing of repair).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2021
Resolved 29 March 2021
Resolution: Objective evidence documented acceptable hull repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 October 2020 Resolved
Towing Vessel Record (TVR) required to include safety orientation training for each crew member on a particular vessel IAW 46 CFR 140.410. TVR did not identify whether or not crew members had completed safety orientation for the particular vessel. Update TVR to record all items listed in 46 CFR 140.410(d) for completion of safety orientation by all crew members.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2020
Resolution: Training provided to crew on 03NOV2020 and TVR updated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 October 2020 Resolved
Towing Vessel Record (TVR) required to include navigation safety training IAW 46 CFR 140.645 for each crew member (other than able body seamen and licensed officers) prior to assuming duties related to the safe operation of a towing vessel. TVR did not include a record of training. Make available TVR showing records of crew member navigation safety training (date, member, trainer).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2020
Resolution: Training provided to crew on 03NOV2020 and TVR properly updated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2020 Resolved
Fire hose required to be 50 feet in length. Fire hose on board vessel was 100 feet. Correct length hose required to be placed on board vessel.(CORRECTED)
Action required: 10 - Deficiency Rectified
Resolved 22 October 2020
Resolution: Fire hose of the required length placed on board vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 October 2020 Resolved
Emergency lighting must be provided for all internal crew working areas along escape routes. Stair well from main deck to second deck not equipped with lighting. Install proper lighting or lighting strips at stairwell.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2020
Resolution: Non-electric, phosphorescent adhesive lighting strips are installed along escape route.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 October 2020 Resolved
Work vest PFDs required to meet 46 CFR 160.053 (Type V). Work vests on board were of a different type (Type III). Remove unapproved work vests (or request/obtain OCMI special consideration).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 November 2020
Resolution: Request for special concideration received from vessel operator. Deficinecy marked corrected while requst is processed for OCMI approval.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2020 Resolved
Semi-portable fire extinguisher required to be permanently attached to vessel structure. Extinguisher was mounted on a hook. Properly secure extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2020
Resolution: Semi-portable fire extinguisher permanently attached to vessel structure.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 October 2020 Resolved
Semi-portable fire extinguisher required to protect engine room. Extinguisher was installed in a location that could not reach the engine room. Re-locate extinguisher to adequately reach all areas in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2020
Resolution: Semi-portable fire extinguisher moved to a position where it could be used to protect the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 October 2020 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. Starboard main diesel engine leaked motor oil at top of engine. Leak required to be properly secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2020
Resolution: Vessel crew proved proper operation of equipment without leaks; leaky seals replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 22 October 2020 Resolved
Machinery spaces openings required to have closures. Ventilators did not have a means to close & stack damper did not fully close. Equip vessel with means to close openings and prove proper operation of damper.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2020
Resolution: Dampners installed in ventilation intakes (2). Vessel crew proved proper operation of exhaust and intake dampners.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 22 October 2020 Resolved
Exposed hazards must be protected. Port generator vibration damper not fitted with a guard. Install a proper cover, guard, or rail on damper.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2020
Resolution: New guard fitted on port generator.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 22 October 2020 Resolved
Vessel required to afford protection against hazards. Hydro pneumatic potable water tank not secured. Properly secure tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
Resolution: Metal staying strap installed around tank near top.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 October 2020 Resolved
Generator and main diesel engines alarms (high water temp & low lube oil pressure) and hydraulic steering tank alarm (low level) required to be test. Make alarms available for testing in presence of a marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 19 August 2021
Resolution: All alarm set points performed satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 October 2020 Resolved
Watertight doors (WTD) required to function properly. WTD found to have a painted gasket. Properly renew gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2020
Resolution: New gausket installed in WTD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 October 2020 Resolved
Main diesel engine and genset required to be equipped with lube oil pressure, water temp, and RPM gauges. Hydraulic steering system required to be fitted with a pressure gauge. Gauges required to be at the machinery location. Equipment was not equipped with gauges. Install & prove proper operation of required gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 7 May 2021
Resolution: Gauges properly installed on mains and generators.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 October 2020 Resolved
Vessel required to be outfitted with an illuminated magnetic compass (or swing-meter) at the operator's station. Installed compass was not illuminated. Prove proper operation of illuminated compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 November 2020
Resolution: Vessel rep proved proper operation of illuminated magnetic compass.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 October 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2020
Resolved 2 December 2020
Resolution: Copy of valid FCC Station License provided as objective evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 October 2020 Resolved
Vessel required to be fitted with stern light IAW 33 CFR 88.24. Stern light was inoperable. Prove proper operation of light prior to operating at night or in restricted visibility conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2020
Resolution: Light fixture repaired and operational.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 October 2020 Resolved
Rails or equivalent protection required to be installed around periphery of all decks. Texas deck was not equipped with protection. Install protective devices (lifelines, wire rope, chains, or bulwarks) at periphery of Texas deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2020
Resolution: Rails and chains installed at periphery of Texas deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 October 2020 Resolved
Electrical systems must minimize shock hazards. Electrical box on exterior bulkhead, port side of stern, was not watertight & contained a disconnected "dead end" cable. Make box watertight and remove dead end cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 November 2020
Resolution: Cable re-connected to system and box made watertight.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 March 2007 Resolved
Cover exposed exhaust elbows on both main engines and generators by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Due 2 April 2007
Resolved 4 April 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 11 March 2007 Resolved
Ensure vessel has a BV(5) extinguisher on board or an installed system.(As required by Aprill 2005) See COTP order 008-07
Action required: 705 - Other - as specified
Due 2 April 2007
Resolved 4 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 11 March 2007 Resolved
Ensure damage to port side is repaired and approved by a Coast Guard inpector by the specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 4 April 2007
Engineering › Bilge Water Management System › Piping
Issued 11 March 2007 Resolved
Clean bilges and remove all foreign materials.(Properly remove anit-freeze, diesel fuel and grease. Remove rags, fuel filters, and Windex bottles from bilges) by specified date IAW COTP order 008-07
Action required: 705 - Other - as specified
Resolved 4 April 2007
Engineering › Bilge Water Management System › Piping
Issued 11 March 2007 Resolved
Properly remove and clean bilges of large amounts of grease in shaft alley(Port and Starboard side) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 March 2007 Resolved
Place guards over exposed pulleys on outboard side of port and starboard generator's by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 March 2007 Resolved
Ensure all breakers are labeled properly in electrical panel by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Lifesaving › Lifebuoys › Serviceable
Issued 11 March 2007 Resolved
Replace batteries for ring buoy float lights to ensure they are in compliance with manufacturer's specifications(Ensure batteries are post style and not spring style) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 11 March 2007 Resolved
Permanently mount clothes dryer receptacle(It is currently laying on the deck) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 March 2007 Resolved
Permanently mount power cable for arc welder(Currently hanging on breaker panel) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 March 2007 Resolved
Permanently mount or remove batteries which are sitting on engine room deck(Port Side Aft) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 11 March 2007 Resolved
Permanently install clothes dryer vent to exhaust outside of the engine room(Currently exhaust is discharging into the engine room down on the turbo charger area and on the port main engine) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 March 2007 Resolved
Conduct proper training on station bill(Crew was unaware on procedures to operate fire pump. Captain was the only crew member to demonstrate proper operation of the fire pump) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Engineering › Bilge Water Management System › Not Installed
Issued 11 March 2007 Resolved
Properly install permanent shaft alley bilge system(Currently the vessel is using a temporary garden hose and extenstion cord running into the bilge and out of the engine room window) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Engineering › Generator (propulsion-electric) › Wiring
Issued 11 March 2007 Resolved
Make repairs to starboard generator crankcase breather piping(Currently piping into bucket) by specified date IAW COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 11 March 2007 Resolved
Adjust or repack both port and starboard shaft packing(excessive leaking straight stream) by specified date in COTP order 008-07.
Action required: 705 - Other - as specified
Resolved 4 April 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.