Records from 1994 to 2024. Most recent: inspection, 18 November 2024.
Documentation record
Registered dimensions (L × B × D)117.0 ft × 27.5 ft × 10.7 ft
Registered tonnagegross 307 / net 209
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNASHVILLE BRIDGE COMPANY · NASHVILLE, TN, UNITED STATES · built 1952
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLEDBETTER, KY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it307 - Regulatory (Subpart C or D), Gross Ton
209 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 36
18 November 2024
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8036319
21 April 2019
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6667148
21 April 2019
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6668029
16 April 2019
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6667765
7 April 2019
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6667645
28 September 2018
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 6553738
26 September 2018
DAPI Audit
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6549452
21 July 2018
In-Service Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6488072
21 July 2018
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6489610
21 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6518748
28 July 2017
Industry Initiated Exam · Administration
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6236551
22 February 2017
Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6313201
15 September 2011
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4146701
16 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363949
20 August 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3033636
21 June 2007
Type not recorded
No type recorded · Maritime Safety & Security Team Houston (91104) · Activity 2970131
3 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2903135
11 September 2006
Damage Survey · Uninspected Other
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2775087
5 October 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2216461
22 August 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2174152
19 August 2004
MTSA Verification
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2170677
29 June 2004
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2196540
9 June 2004
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2098808
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978893
16 October 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1732466
2 July 2002
Uninspected Towing Vessel
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1640760
2 July 2002
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1646364
30 August 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 136520
6 December 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 11777
5 October 2000
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 33347
16 April 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 436901
20 March 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 401912
27 May 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1085485
26 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 119025
20 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 120563
14 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70367
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 April 2019
Resolved
The stern void is taking on water. Locate leak and make permanent repairs iaw NVIC 7-68.
Action required: 30 - Ship detained
Resolved 17 March 2025
Resolution: District 8 declared vessel laid up and out of service. No objective evidence received of deficiency resolution. Actual proof of requirement resolution not obtained.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 21 April 2019
Resolved
The bilges are being used to store waste oil/slops. Pump and clean all oily waste and residue from bilges.
Action required: 30 - Ship detained
Resolved 17 March 2025
Resolution: District 8 declared vessel laid up and out of service. No objective evidence received of deficiency resolution. Actual proof of requirement resolution not obtained.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 April 2019
Resolved
There is moving machinery in the engine room without guards in place. Place guards around all moving machinery.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 17 March 2025
Resolution: District 8 declared vessel laid up and out of service. No objective evidence received of deficiency resolution. Actual proof of requirement resolution not obtained.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 21 April 2019
Resolved
The port main engine is leaking/spraying oil from the back of the engine. Make permanent repairs to prevent oil from leaking/spraying onto deck/bilges.
Action required: 30 - Ship detained
Resolved 17 March 2025
Resolution: District 8 declared vessel laid up and out of service. No objective evidence received of deficiency resolution. Actual proof of requirement resolution not obtained.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 April 2019
Resolved
Make permanent repairs to stbd side of vessel to repair damage to second deck from marine casualty.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2025
Resolution: District 8 declared vessel laid up and out of service. No objective evidence received of deficiency resolution. Actual proof of requirement resolution not obtained.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 April 2019
Resolved
Make repairs to handrails/stanchions on port stern of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2025
Resolution: District 8 declared vessel laid up and out of service. No objective evidence received of deficiency resolution. Actual proof of requirement resolution not obtained.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 July 2018
Resolved
Excessive accumulation of lube oil in engine room bilge
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2018
Resolved 24 July 2018
Resolution: Vessel pumped bilges and submitted satisfactory receipts from an authorized source as objective evidence.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2018
Resolved
FCC station license was issued to previous owner and had been cancelled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2018
Resolved 31 July 2018
Resolution: Vessel owner provided copy of FCC station license
Construction/Loadline › Hull › Bottom Plating
Issued 11 September 2006
Resolved
Hole or possible fracture was located in the bottom hull plating approx. 3' outboard of the port rudder post housing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2006
Lifesaving › Lifebuoys
Issued 2 July 2002
Resolved
Water lights on port and starboard life bouys not working LEGACY COMPONENT DESC: Self-igniting Lights
Due 2 August 2002
Resolved 3 September 2002
Resolution: New batteries in strobe lights
Communications › Alarms/Indicators
Issued 2 July 2002
Resolved
Fire Detection System not certified IAW 46 CFR 27.210 (g) LEGACY COMPONENT DESC: Fire Alarm
Due 2 August 2002
Resolved 3 September 2002
Resolution: Letter from professional engineer produced
Documentation › Logs/Records
Issued 2 July 2002
Resolved
No record of tests IAW 33 CFR 164.78 LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Due 2 August 2002
Resolved 3 September 2002
Resolution: Records entered in the log book
Pollution Prevention/Response › Prevention Equipment
Issued 2 July 2002
Resolved
MSD missing label IAW 33 CFR 159.7 LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 2 August 2002
Resolved 3 September 2002
Resolution: MSD was labeled
Pollution Prevention/Response › Prevention Equipment
Issued 2 July 2002
Resolved
MSD missing placard IAW 33 CFR 159.59 LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 2 August 2002
Resolved 3 September 2002
Resolution: Placard was posted
Communications › Alarms/Indicators
Issued 2 July 2002
Resolved
General Alarm not installed IAW 46 CFR 27.205(a)(3) LEGACY COMPONENT DESC: General Alarm
Due 2 August 2002
Resolved 3 September 2002
Resolution: Red light was installed