Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2005
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 43 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 29 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 43
15 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8187355
14 October 2024
Examination of Repairs · Cargo Tank Internal · Drydock Exam · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8018767
9 March 2022
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7408174
23 February 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7144999
17 December 2019
Examination of Repairs · MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6863898
31 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6618318
6 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6350472
5 January 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6065614
25 January 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5848000
6 January 2016
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5792102
5 January 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5791378
21 October 2014
COI Inspection · Cargo Tank Internal · MTSA Verification · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5005723
9 September 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4983608
22 June 2014
Damage Survey
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4898761
22 June 2014
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4899125
8 August 2013
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4676071
9 August 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4403803
20 December 2011
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4226859
25 October 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4188953
16 September 2011
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4147035
8 December 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3922980
14 September 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3849688
18 June 2010
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3768149
14 August 2009
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3564994
17 June 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3506492
19 March 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3436099
11 March 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3431814
6 March 2009
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3430310
12 January 2009
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3392813
17 September 2008
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3358350
15 July 2008
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3267928
1 July 2008
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3253534
22 May 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3213436
26 April 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3196273
17 March 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3167406
7 January 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3126494
20 November 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3101730
25 June 2007
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2973720
3 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2903135
26 February 2007
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2877924
1 June 2006
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2665929
23 May 2005
Cargo Tank Internal · Initial Certification · Hull Examination · Internal Structural Exam · MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2365636
28 April 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2344837
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 July 2025
Resolved
Damage to hull on headlog of the bow. Damage contains an approximately 3x3 sharp inset with damage to the push knees. All Types I, II, and III barges shall comply with the basic structural requirements of the American Bureau of Shipping for barges of the ordinary types and the applicable supplementary requirements of this section. Voyage of barge allowed to continue to New Orleans to discharge of cargo then to enter emergency dry dock for repairs of the inset.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 30 July 2025
Resolved 1 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2019
Resolved
Junction box for overfill protection system was found broke free of mounting surface. Fittings for electrical cables entering the box were found wasted. Mount box and replace fittings with appropriate replacements. Vessel is restricted to carrying cargos with a flashpoint of 140* F or above until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2019
Resolved 13 February 2019
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 January 2016
Resolved
Vessel is authorized to carry polymerizing cargoes, but MIs were unable to inspect the vapor control piping system. Prior to loading cargo, vessel shall make vapor control piping system available for internal inspection, no later than 04FEB2016. If polymerizing cargoes have not been carried in the last 12 months, the OCMI may accept documentation attesting to no polymerizing cargoes carried.
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 6 January 2016
Resolution: Received documentation attesting that vessel did not carry polymerizing cargoes in the last 12 months.
Construction/Loadline › Structures › Manhole
Issued 9 September 2014
Resolved
Repair or replace all port and starboard wing tank hatch covers that are either cracked or wasted away at next dry dock IAW the next scheduled DD 2015.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2014
Resolution: Replaced with new hatch covers.
Engineering › Diesel Engine (auxiliary) › Block
Issued 23 June 2010
Resolved
Re-install port side cargo pump engine IAW 46 CFR 32.35-5 and IAW 46 CFR subchapter "F". Test and ensure proper function of engine emergency shutdown IAW 46 CFR 32.50-35 in the presence and to the satisfaction of an attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 August 2010
Resolved 14 September 2010
Resolution: Observed new engine and tested ESD.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 1 July 2008
Resolved
Two electronically controlled [name withheld] prime movers require Class 1, Division 1 hazardous requirements iaw 46 CFR 111.105-31(1), IAW D8 (dp) Policy letter 02-2007 Ch1 (15AUG07).
Due 1 August 2008
Resolved 14 September 2010
Resolution: Observed engine, cleared deficiency.
Deck/Cargo › Cargo Stowage › General
Issued 25 February 2007
Resolved
Following the allision with the USNS FISHER the HFL 402 is not to conduct cargo operations until the #1 and #2 cargo tanks (port side) are pressed with air to 1psig. If no leaks are present (as indicated by a soap test) then the vessel will be considered fit for service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2007
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 1 June 2006
Resolved
Vessel has 2 electronically controlled [name withheld] prime movers. Prove to USCG inspector that all components meet class 1, division 1 hazardous area requirements in accordance with 46 CFR 111.105-31(1).
Due 1 August 2007
Resolved 1 June 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 June 2006
Resolved
Vessel had a copy of the current COI but did not have the original COI onboard. Make original COI available to USCG inspector and maintain it onboard vessel at all times.
Action required: 705 - Other - as specified
Resolved 25 February 2007