Documentation record
Registered dimensions (L × B × D)60.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 88 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderL & A IRON WORKS INC · GRAND BOIS, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portPORT OF NEW IBERIA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 7 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Simplified, Gross Ton
70 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 37 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 12 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 37
23 June 2025
COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8150738
25 October 2024
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8024580
10 October 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8000496
24 July 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7966079
18 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7810565
1 November 2022
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7593832
25 August 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7543686
19 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7335406
20 July 2020
Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7011379
1 February 2020
Type not recorded
No type recorded · USCGC SAWFISH (WPB 87357) · USCG Southeast District (CGD-SE) · Activity 6903815
22 May 2017
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6152471
22 May 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6152477
22 August 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6018278
2 July 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4906982
17 January 2013
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4517729
16 November 2010
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937345
8 July 2008
MTSA Verification · Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3263717
8 July 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3268562
2 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2616358
21 October 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2225631
11 December 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1962801
11 October 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1702269
6 May 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1616718
19 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 212422
12 July 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 214505
31 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 180581
6 June 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 154653
26 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 523020
16 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 38080
16 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 107437
21 February 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 528730
25 October 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 184665
10 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 9473
14 August 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 381681
13 January 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 177585
30 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 661384
26 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 454081
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 October 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Port main diesel engine was found with no exhaust lagging on the turbo charger. Install lagging on turbo.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 25 October 2024
Resolution: Received objective evidence that lagging is in place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024
Resolved
Lifejackets must have the following attachments and fittings: Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. 03 lifejackets were found with expired lights. Vessel crew replaced lights with approved lights that were on board.
Action required: 10 - Deficiency Rectified
Due 10 October 2024
Resolved 10 October 2024
Resolution: Vessel crew replaced lights with approved lights that were on board.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 October 2024
Resolved
Survival craft and stowage locations must be marked in accordance with the requirements of §§ 199.176 and 199.178 of this chapter. The number of persons for which the boat is equipped must be clearly marked in permanent characters. Life float was found with no number of persons marked. Crew marked 6 persons as shown on nameplate on the lifefloat.
Action required: 10 - Deficiency Rectified
Due 10 October 2024
Resolved 10 October 2024
Resolution: Crew marked 6 persons as shown on nameplate on the lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 October 2024
Resolved
Each life float and rigid buoyant apparatus must be fitted with a lifeline, pendants, a painter, and floating electric water light approved under approval series 161.010. Water light had unapproved battery as per manufacturer's instructions. Crew replaced with properly approved battery.
Action required: 10 - Deficiency Rectified
Due 10 October 2024
Resolved 10 October 2024
Resolution: Crew replaced with properly approved battery.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 19 October 2021
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. The fwd port supply valve was leaking fuel past the seat. Repair valve.
46CFR142.220
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 20 October 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 October 2021
Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. The radio was inop on E-power. Replace dead battery.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 October 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 October 2021
Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. The call sign and the MMSI# was incorrect on the VHF radio.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2021
Resolved 20 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 October 2021
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with one or more spring-loaded relief valves. The R/V was missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2021
Resolved 20 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 October 2021
Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure and main engine RPM. The RPM gauge was inop. Repair or replace gauge.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 November 2021
Resolved 29 October 2021
Resolution: Main Engine RPM gauge is now in working condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 July 2020
Resolved
An unknown fault in the fuel shut off valve is suspected to be the cause of a loss of propulsion while underway. Provide tech report attesting to proper operation of fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2020
Resolved 20 July 2020
Resolution: Received video attesting to replacement of emergency fuel shut off valve.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 July 2020
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces. Provide closure device for one vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 21 August 2020
Resolution: Received documentation attesting to installation of closure devices for vet.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 July 2020
Resolved
In areas where space limitations make deck rails impractical hand grabs may be substituted. Provide rails or equivalent protection.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 28 July 2020
Resolution: Received pictures of hand rails.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. The pressure vessel is not labeled with MAWP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 19 August 2020
Resolution: Received documentation attesting to labeling of pressure vessel MAWP.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 July 2020
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Electrical and circuit breakers are not labeled in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 21 August 2020
Resolution: Received documentation attesting to proper labeling of circuit breakers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2020
Resolved
Both life buoys on board had a lifeline. Remove one lifeline. 02 lifebuoys on board had non detachable water lights. At least one water light must be attached by the lanyard with a corrosion resistant clip to allow the water light to be quickly disconnected from the lifebuoy. Vessel shall ensure at least one lifebuoy with water light is detachable with a corrosion resistant clip.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 31 July 2020
Resolved 21 August 2020
Resolution: Received dcoumentation attesting to installation fo corrosion resistant clip.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 July 2020
Resolved
Vessel was not conducting monthly test of EPIRB. Inspections and tests of lifesaving equipment must be recorded in the TVR or official logbook.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 21 August 2020
Resolution: Received documentation of life saving equipment, including EPIRB, monthly test.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 8 July 2008
Resolved
Determine the source of fuel leak on STBD engine, repair, and provide technicians report of satisfactory completion.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2008
Resolution: Received mechanics report verifying repairs and proper operation of the engine.