Records from 1992 to 2013. Most recent: inspection, 16 January 2013.
Inspection history · 25
16 January 2013
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4517184
21 March 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3889815
14 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3363446
24 January 2007
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2919076
26 October 2006
Uninspected Other
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2808702
19 October 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2803929
26 July 2006
Uninspected Other
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2725865
15 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2812023
5 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2641309
1 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2637999
23 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2610966
2 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2616358
5 February 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2586629
4 February 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2623745
15 November 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2548097
7 November 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2531777
17 March 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2312904
1 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2267344
12 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 41716
12 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 153254
23 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083048
28 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 669382
22 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 452195
3 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 512529
30 August 1992
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1258744
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 26 October 2006
Resolved
Vessel may not operate until a properly licensed master is onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2006
Resolved 24 January 2007
Resolution: License on Master of vessel was provided.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 October 2006
No resolution recorded
Remove oily water from bilge to an approved facility.
Due 10 November 2006 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Gasket
Issued 26 October 2006
No resolution recorded
Dry dock vessel and make permanent repairs to the port and starboard leaking shafts into the bilge.
Action required: 705 - Other - as specified
Due 10 November 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 October 2006
Resolved
Remove the washing machine from the machinery space or provide an alternative system of removeing the grey water.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 24 January 2007
Resolution: Washing machine was removed from the machinery space.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 26 October 2006
No resolution recorded
Make repairs to the Center engine.
Action required: 705 - Other - as specified
Due 10 November 2006 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 26 October 2006
No resolution recorded
Remove the oily water mixture to an approved facility. Make permanent repairs to the steering hydraulic system. Locate the source of the water leaking into the compartment and make permanent repairs.
Action required: 705 - Other - as specified
Due 10 November 2006 — due date passed with no resolution recorded
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 26 October 2006
Resolved
Install an operable MSD. Lock the overboard discharge valve in the closed position..
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 24 January 2007
Resolution: MSD was found operational. Witness overboard discharge valve in a locked state.
Navigation › Piloting/Steering › Marine Charts
Issued 26 October 2006
Resolved
Provide updated charts for all areas of operation.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 24 January 2007
Resolution: Old Charts have been replaced with current ones for area of operation.
Engineering › Steering Gear System › Rudder
Issued 26 October 2006
Resolved
Reinstall mising Center rudder.
Action required: 705 - Other - as specified
Due 10 November 2006
Resolved 24 January 2007
Resolution: Center Rudder was replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 July 2006
Resolved
No certification of Documentation
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Captain of the vessel provided a current application for documentation. Current Cert of Documentation expired 31May2006.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 26 July 2006
Resolved
Non operable MSD type II* on board
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Sneed shipyard repaired MSD and serviced in-operable isolation valves.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 26 July 2006
Resolved
Draining washing machine intentionally into Oily bilge
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Vessel removed the laundry washing machine off the vessel.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 26 July 2006
Resolved
No provisions for pumping off clean shaft alley water
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Vessel uses a portable pump to drain shaft alley bilges.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 July 2006
Resolved
Fire fighting equipment overdue on hydorstatic test
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Fire fighting equipment inspected and labeled by local company.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 26 July 2006
Resolved
Pumping oily bilge overboard as per Capt.'s own admission to [name withheld]
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Vessel employed a local oily slop disposal company to empty bilges. Bilges are dry.
Stability › Unintentional Flooding › General
Issued 26 July 2006
Resolved
Stern Void taking on water
Action required: 705 - Other - as specified
Resolved 9 August 2006
Resolution: Void was dry upon inspection. Vessel Captain provided daily void inspection log. No hull breach was detected while in dry dock.