MAURY USCG vessel records
← All vessels

NA HOKU

Built
1981
Last inspected
12 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 12 March 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 18 calendar years (1991–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8973904
WDG7908
198423
Flag
UNITED STATES
Maury page id
psix-198423

Documentation record

Registered dimensions (L × B × D)95.3 ft × 34.0 ft × 13.5 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)98.5 ft × 34.0 ft × 17.0 ft
ITC tonnagegross 375 / net 112
BuilderHALTER MARINE INC · LOCKPORT, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHARLESTON, SC
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 29 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
375 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
112 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 11 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 29

12 March 2026 Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8325605
2 April 2024 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7888611
1 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7832231
3 August 2023 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7759822
8 January 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7618182
21 September 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7563674
13 October 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7334998
17 September 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7316702
8 September 2020 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7062304
2 December 2019 Deficiency Check · Initial Certification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6865368
1 September 2017 Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6255981
20 April 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6131430
23 September 2014 DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4990436
25 October 2011 Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4175614
12 December 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3114296
11 December 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3117200
5 October 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3073921
7 May 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2984154
18 May 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2071194
13 May 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2066824
30 April 2004 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2061945
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997322
27 January 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 655843
4 January 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 153527
9 May 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 56585
13 December 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 398510
9 July 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 104879
12 October 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 46185
29 November 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 112403

Deficiency record · 21

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 March 2026 No resolution recorded
Open structures. (1) Structures that are located on or above the line of the uppermost complete deck that are under cover (sheltered) but open to the weather are exempt from gross tonnage. (5) An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hook bolts (see § 69.123, Figure 12) is considered open to the weather— (i) If hook bolts used to secure cover plates or boards are spaced at least one foot apart and hook over a stiffener installed around the perimeter of the opening:(ii) If the cover plates or boards fit tightly against the bulkhead; and (iii) If battening, caulking, or gaskets of any material are not used. Multiple tonnage openings were found sealed with caulk, adhesive, and/or rubber gasket material.
Condition: Improper Installation
Action required: 705 - Other - as specified
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 October 2021 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Berthing areas and engine room have inadequate emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 29 October 2021
Resolution: Installed battery powered light in engine room and phosphorescent adhesive lighting strips in berthing areas.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 13 October 2021 Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations. Inspections are being conducted but items are not identified during the inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Vessel updated its towing gear inspection log and marked towing gear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2021 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Electrical distribution panels not accurately marked.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Vessel verified and updated markings on panels to reflect loads installed on them.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 13 October 2021 Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Missing the required number per 160.040 and 2 buoyant projectiles
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Vessel placed in service the addational line throwing devices and bouyant projectiles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2021 Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards must wear a lifejacket meeting requirements in 46 CFR 141.340, an immersion suit meeting requirements in 46 CFR 141.350, or a work vest approved by the Commandant under 46 CFR subpart 160.053. Work vest not per above type approval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Work vest of the propper approval were placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 13 October 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Upper wheel house has insufficient railing to prevent falls. Complete at next scheduled dry dock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 21 September 2022
Resolution: Rails were adequate IWO upper pilot house.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 July 2020 Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable. Vessel operates on oceans route and does not have Bridge to Bridge radio certificate. Limited to lakes bays and sounds route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 July 2020
Resolution: Vessel recieved a bridge to bridge certifcate.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 July 2020 Resolved
Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104 (incorporated by reference, see §136.112 of this subchapter) or other standards accepted by the Coast Guard. Lights operated but indicator or alarms were operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 9 September 2020
Resolution: Navigation Light panel was installed and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020 Resolved
life saving appliances and stowage locations must be marked in accordance with the requirements of §§199.176 and 199.178 of this chapter. Qty was not marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel marked the qty on all lifesaving storage locations.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 20 July 2020 Resolved
An auxiliary line that: (i) Is at least 450 meters (1,500 feet) long; (ii) Has a breaking strength of at least 40 kilonewtons (9,000 pounds-force) Line is missing
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel place in service on the vessel a spool of line meeting the requirements of auxiliary line.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 July 2020 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Charts were not current or corrected
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel place in service up to date charts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 July 2020 Resolved
The following systems must be equipped with gauges at the machinery location: (1) Main engine lubricating oil pressure and main engine RPM. STBD MDE rpm gauge was inoperable
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel replaced the gauge and conduted test to verify operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2020 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Cardboard is being used to redirect engine room ventilation. unused cardboard is being stored in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel removed excess cardboard from the engine room.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 24 February 2020 Resolved
If a vessel that is already measured is to undergo a structural alteration or if the use of a space within that vessel is to be changed, a re-measurement my be required. According to survey for load lines dated 09 Dec 1980. 09 tonnage openings were used in the measurements. Page 2 of 12 has detailing locations of referenced openings. Survey pages 3,4 and 6 has detailed specifications regarding the openings. According to survey openings 1 and 2 require J-Bolts to be used. at some point J-Bolts were removed and replace with standard bolts. Vessel must come back into compliance with load line referenced above or be resurveyed. with current configuration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 1 June 2020
Resolution: Pictures were received showing J-Bolts installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 February 2020 Resolved
The statutory authority to prescribe rules and regulations requiring certain vessels to have and display load line marks indicating the maximum amidships draft to witch such vessels may be safely loaded and certification by the assigning authority. vessel is displaying a load line on side vessel with no load line certificate on board. vessel also has its load line submerged.
Action required: 10 - Deficiency Rectified
Due 20 February 2020
Resolved 20 February 2020
Resolution: Vessel reduced ballast water in vessel to unsubmerged load line mark and Load line certificate was issued to vessel that day and was digitally transmitted to vessel, paper copy will follow.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2019 Resolved
Shapes shall be black and of the following sizes: (i) A ball shall have a diameter of not less than 0.6 meter. (ii) A cone shall have a base diameter of not less than 0.6 meters and a height equal to its diameter. (iii) A diamond shape shall consist of two cones (as defined in paragraph (a)(ii) of this section) having a common base. (b) The vertical distance between shapes shall be at least 1.5 meters. Ball day shapes are missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel placed ball day shapes in service on the vessel.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 2 December 2019 Resolved
Radiotelephony stations subject to the Great Lakes Agreement and the Bridge-to-Bridge Act must record entries indicated by paragraphs (e)(1), (3), (5), (6), (7), (8), (10), (11), and (13), and of this section. Additionally, the radiotelephone log must provide an easily identifiable, separate section relating to the required inspection of the ship's radio station. Radio log was not per the requirements.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel placed in service meeting the requirements of a radio log
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 2 December 2019 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. (b) Each garbage management plan under paragraph (a) of this section must be in writing and— (1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§151.51 through 151.77; (2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and (3) Designate the person who is in charge of carrying out the plan. Was not present
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel implemented and placed in service a garbage management plan.
Pollution Prevention/Response
Issued 30 April 2004 Resolved
While conducting a MLE boarding, noted excessive oil/water in engine room bilges. Issued COTP order to remove oily water from engine room bilges prior to the vessel departing Port Hueneme.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2004
Resolved 1 May 2004
Resolution: Contractor Ecology Control Industries, US EPA # CA0782030173, removed 2000 gallons of oily bilge water from engine room bilges.
Construction/Loadline
Issued 13 December 1996 Resolved
NAME AND HOMEPORT WERE NOT MARKED ON THE STERN OF THE VESSEL. 46 CFR 67.123
Condition: Unknown
Due 13 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.