Inspection history · 29
12 March 2026
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8325605
2 April 2024
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7888611
1 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7832231
3 August 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7759822
8 January 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7618182
21 September 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7563674
13 October 2021
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7334998
17 September 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7316702
8 September 2020
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7062304
2 December 2019
Deficiency Check · Initial Certification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6865368
1 September 2017
Industry Initiated Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6255981
20 April 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6131430
23 September 2014
DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4990436
25 October 2011
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4175614
12 December 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3114296
11 December 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3117200
5 October 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3073921
7 May 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2984154
18 May 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2071194
13 May 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2066824
30 April 2004
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2061945
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997322
27 January 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 655843
4 January 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 153527
9 May 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 56585
13 December 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 398510
9 July 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 104879
12 October 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 46185
29 November 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 112403
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 March 2026
No resolution recorded
Open structures. (1) Structures that are located on or
above the line of the uppermost complete deck that are
under cover (sheltered) but open to the weather are
exempt from gross tonnage. (5) An interior or exterior
opening that is temporarily closed by cover plates or
boards held in place only by hook bolts (see § 69.123,
Figure 12) is considered open to the weather— (i) If
hook bolts used to secure cover plates or boards are
spaced at least one foot apart and hook over a stiffener
installed around the perimeter of the opening:(ii) If
the cover plates or boards fit tightly against the
bulkhead; and (iii) If battening, caulking, or gaskets
of any material are not used. Multiple tonnage openings
were found sealed with caulk, adhesive, and/or rubber
gasket material.
Condition: Improper Installation
Action required: 705 - Other - as specified
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 October 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
Berthing areas and engine room have inadequate emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 29 October 2021
Resolution: Installed battery powered light in engine room and phosphorescent adhesive lighting strips in berthing areas.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 13 October 2021
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The following minimum information is required in the record: The dates when examinations were performed, the identification of each item of towing gear examined, and the name(s) of the person(s) conducting the examinations.
Inspections are being conducted but items are not identified during the inspections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Vessel updated its towing gear inspection log and marked towing gear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2021
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve.
Electrical distribution panels not accurately marked.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Vessel verified and updated markings on panels to reflect loads installed on them.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 13 October 2021
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040.
Missing the required number per 160.040 and 2 buoyant projectiles
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Vessel placed in service the addational line throwing devices and bouyant projectiles.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2021
Resolved
Personnel dispatched from the vessel or that are working in an area on the exterior of the vessel without rails and guards must wear a lifejacket meeting requirements in 46 CFR 141.340, an immersion suit meeting requirements in 46 CFR 141.350, or a work vest approved by the Commandant under 46 CFR subpart 160.053.
Work vest not per above type approval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 29 October 2021
Resolution: Work vest of the propper approval were placed in service.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 13 October 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails.
Upper wheel house has insufficient railing to prevent falls. Complete at next scheduled dry dock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 21 September 2022
Resolution: Rails were adequate IWO upper pilot house.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 July 2020
Resolved
Towing vessels must meet the communications requirements of 33 CFR part 26 and 33 CFR 164.72, as applicable.
Vessel operates on oceans route and does not have Bridge to Bridge radio certificate. Limited to lakes bays and sounds route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 27 July 2020
Resolution: Vessel recieved a bridge to bridge certifcate.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 July 2020
Resolved
Towing vessels more than 65 feet in length must use navigation lights that meet UL 1104 (incorporated by reference, see §136.112 of this subchapter) or other standards accepted by the Coast Guard.
Lights operated but indicator or alarms were operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 9 September 2020
Resolution: Navigation Light panel was installed and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020
Resolved
life saving appliances and stowage locations must be marked in accordance with the requirements of §§199.176 and 199.178 of this chapter.
Qty was not marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel marked the qty on all lifesaving storage locations.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 20 July 2020
Resolved
An auxiliary line that:
(i) Is at least 450 meters (1,500 feet) long;
(ii) Has a breaking strength of at least 40 kilonewtons
(9,000 pounds-force)
Line is missing
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel place in service on the vessel a spool of line meeting the requirements of auxiliary line.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 July 2020
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage.
Charts were not current or corrected
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel place in service up to date charts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 July 2020
Resolved
The following systems must be equipped with gauges at the machinery location:
(1) Main engine lubricating oil pressure and main engine RPM.
STBD MDE rpm gauge was inoperable
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel replaced the gauge and conduted test to verify operation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2020
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following:
(a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable.
Cardboard is being used to redirect engine room ventilation. unused cardboard is being stored in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel removed excess cardboard from the engine room.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 24 February 2020
Resolved
If a vessel that is already measured is to undergo a structural alteration or if the use of a space within that vessel is to be changed, a re-measurement my be required. According to survey for load lines dated 09 Dec 1980. 09 tonnage openings were used in the measurements. Page 2 of 12 has detailing locations of referenced openings. Survey pages 3,4 and 6 has detailed specifications regarding the openings. According to survey openings 1 and 2 require J-Bolts to be used. at some point J-Bolts were removed and replace with standard bolts. Vessel must come back into compliance with load line referenced above or be resurveyed. with current configuration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 March 2020
Resolved 1 June 2020
Resolution: Pictures were received showing J-Bolts installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 February 2020
Resolved
The statutory authority to prescribe rules and regulations requiring certain vessels to have and display load line marks indicating the maximum amidships draft to witch such vessels may be safely loaded and certification by the assigning authority. vessel is displaying a load line on side vessel with no load line certificate on board. vessel also has its load line submerged.
Action required: 10 - Deficiency Rectified
Due 20 February 2020
Resolved 20 February 2020
Resolution: Vessel reduced ballast water in vessel to unsubmerged load line mark and Load line certificate was issued to vessel that day and was digitally transmitted to vessel, paper copy will follow.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2019
Resolved
Shapes shall be black and of the following sizes:
(i) A ball shall have a diameter of not less than 0.6 meter.
(ii) A cone shall have a base diameter of not less than 0.6 meters and a height equal to its diameter.
(iii) A diamond shape shall consist of two cones (as defined in paragraph (a)(ii) of this section) having a common base.
(b) The vertical distance between shapes shall be at least 1.5 meters.
Ball day shapes are missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel placed ball day shapes in service on the vessel.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 2 December 2019
Resolved
Radiotelephony stations subject to the Great Lakes Agreement and the Bridge-to-Bridge Act must record entries indicated by paragraphs (e)(1), (3), (5), (6), (7), (8), (10), (11), and (13), and of this section. Additionally, the radiotelephone log must provide an easily identifiable, separate section relating to the required inspection of the ship's radio station.
Radio log was not per the requirements.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel placed in service meeting the requirements of a radio log
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 2 December 2019
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan.
(b) Each garbage management plan under paragraph (a) of this section must be in writing and—
(1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§151.51 through 151.77;
(2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and
(3) Designate the person who is in charge of carrying out the plan.
Was not present
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 27 July 2020
Resolution: Vessel implemented and placed in service a garbage management plan.
Pollution Prevention/Response
Issued 30 April 2004
Resolved
While conducting a MLE boarding, noted excessive oil/water in engine room bilges. Issued COTP order to remove oily water from engine room bilges prior to the vessel departing Port Hueneme.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2004
Resolved 1 May 2004
Resolution: Contractor Ecology Control Industries, US EPA # CA0782030173, removed 2000 gallons of oily bilge water from engine room bilges.
Construction/Loadline
Issued 13 December 1996
Resolved
NAME AND HOMEPORT WERE NOT MARKED ON THE STERN OF THE VESSEL. 46 CFR 67.123
Condition: Unknown
Due 13 January 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past