MAURY USCG vessel records
← All vessels

MARGARET SUE

Built
1996
Last inspected
28 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 28 April 2026
…with no type recorded31
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1996–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

433358
Flag
UNITED STATES
Maury page id
psix-433358

Documentation record

Registered dimensions (L × B × D)432.0 ft × 62.0 ft × 31.0 ft
Registered tonnagegross 6,179 / net 1,853
ITC dimensions (L × B × D)432.0 ft × 62.0 ft × 31.0 ft
ITC tonnagegross 6,179 / net 1,853
BuilderAMFELS SHIP YARD · BROWNSVILLE, TX, UNITED STATES · built 1996
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUSTON, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 April 2026 · expires 30 April 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6179 - Convention (Subpart B), Gross Ton
1853 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 83 inspections, each with its date, unit and type; 54 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 21 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 21

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LA FORCE Towing Vessel · MISLE 127064 · 9 June 2023 · activity 7710548APOLLO Towing Vessel · MISLE 1242735 · 9 June 2023 · activity 7710548LA FORCE Towing Vessel · MISLE 127064 · 21 June 2022 · activity 7489680CAPT TIMMY CALLAIS Towing Vessel · MISLE 880576 · 21 June 2022 · activity 7489680KIRBY 32300B Tank Barge · MISLE 912602 · 21 June 2022 · activity 7489680MMLP 323 Tank Barge · MISLE 1095120 · 21 June 2022 · activity 7489680MMLP 324 Tank Barge · MISLE 1095122 · 21 June 2022 · activity 7489680JOE B WARD Towing Vessel · MISLE 1105542 · 21 June 2022 · activity 7489680HFL 607 Tank Barge · MISLE 1162048 · 21 June 2022 · activity 7489680HFL 427 Tank Barge · MISLE 1267365 · 21 June 2022 · activity 7489680WILLIAM MILLER Towing Vessel · MISLE 1475341 · 21 June 2022 · activity 7489680MPX 419 Tank Barge · MISLE 1647492 · 21 June 2022 · activity 7489680LA FORCE Towing Vessel · MISLE 127064 · 27 April 2022 · activity 7439165SUWANNEE RIVER Towing Vessel · MISLE 5158 · 5 June 2020 · activity 6971806MARTIN EXPLORER Towing Vessel · MISLE 447069 · 5 June 2020 · activity 6971806MARTIN EXPLORER Towing Vessel · MISLE 447069 · 15 February 2020 · activity 6914827MARTIN EXPLORER Towing Vessel · MISLE 447069 · 2 November 2017 · activity 6299565MARTIN EXPLORER Towing Vessel · MISLE 447069 · 20 June 2016 · activity 5914414ATHENA Towing Vessel · MISLE 1224364 · 20 June 2016 · activity 5914414ORION Towing Vessel · MISLE 64015 · 12 February 2010 · activity 3681306MARTIN EXPLORER Towing Vessel · MISLE 447069 · 17 December 2007 · activity 3117043F W KNOWLES Towing Vessel · MISLE 206579 · 28 June 2006 · activity 2693961MARTIN EXPLORER Towing Vessel · MISLE 447069 · 28 June 2006 · activity 2693961MARTIN EXPLORER Towing Vessel · MISLE 447069 · 26 March 2000 · activity 80727BATON ROUGE Towing Vessel · MISLE 88430 · 9 May 1998 · activity 56585PHILIP K Towing Vessel · MISLE 146225 · 9 May 1998 · activity 56585JAMES MCALLISTER Towing Vessel · MISLE 176437 · 9 May 1998 · activity 56585NA HOKU Towing Vessel · MISLE 198423 · 9 May 1998 · activity 56585MARTIN EXPLORER Towing Vessel · MISLE 447069 · 8 December 1997 · activity 11221TORRENT Towing Vessel · MISLE 56871 · 28 July 1996 · activity 153916

Inspection history · 83

28 April 2026 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8368851
22 March 2024 Deficiency Check · Periodic Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7883555
9 June 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7710548
2 March 2023 Administrative Inspection · Deficiency Check · Examination of Repairs · Internal Structural Exam · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7650040
28 July 2022 Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7518845
21 June 2022 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7485852
21 June 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7489680
1 June 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7470060
27 April 2022 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7439165
12 February 2021 MTSA Verification · Hull Examination · COI Inspection · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7137332
12 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6974547
5 June 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6971806
15 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6914827
10 July 2019 MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6734840
27 February 2019 Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6633179
25 July 2018 Annual Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6481723
14 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6416946
9 April 2018 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6374803
2 November 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6299565
12 April 2017 MTSA Verification · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6118231
20 June 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5914414
22 March 2016 Examination of Repairs · COI Inspection · Cargo Tank Internal · MTSA/ISPS Verification · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5833786
21 September 2015 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5719197
21 January 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5057663
20 November 2014 MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5024911
21 March 2014 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4823233
10 March 2014 Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4810497
4 February 2014 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4793423
3 January 2014 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4776100
7 December 2012 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4497057
5 January 2012 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4217782
29 October 2010 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3880006
4 October 2010 MTSA Verification · COI Inspection · Drydock Extension · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3861333
5 April 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3709748
15 February 2010 Damage Survey · Annual Inspection · Administrative Inspection · Examination of Repairs · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3682395
12 February 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3681306
9 December 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3377075
25 November 2008 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3372811
14 October 2008 MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3344420
26 February 2008 Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3153610
17 December 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3117043
13 July 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2993546
22 May 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2975644
21 May 2007 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2936631
28 June 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2693961
28 June 2006 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2694396
1 March 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2596995
24 October 2005 COI Inspection · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2520660
21 April 2005 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2337173
21 April 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2367821
14 April 2005 MTSA Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2334097
8 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2255690
14 October 2003 Annual Inspection · Hull Examination · MARPOL Annex I Examination · Internal Structural Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1927974
24 February 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1747578
27 July 2002 MARPOL Annex I Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1657196
15 January 2002 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1478858
4 October 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 294354
13 January 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057086
19 December 2000 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1426503
22 September 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 766250
13 September 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 197809
20 April 2000 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048879
27 March 2000 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1047328
26 March 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 80727
16 March 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1048192
18 February 2000 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1399284
2 May 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 533829
31 October 1998 Hull Examination · Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 803687
18 September 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 477911
21 August 1998 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 802464
9 May 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 56585
9 May 1998 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1406318
15 March 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1471375
23 February 1998 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1409839
12 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 457851
8 December 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 11221
14 July 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 488072
24 April 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1102646
26 March 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1413141
10 February 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 524813
28 July 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 153916
14 June 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 502230
27 February 1996 Construction Oversight · Initial Certification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440980

Deficiency record · 54

12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 2 March 2023 Resolved
The following locations in the weather are Class I, Division 1 (Zone 1) locations and may have only approved intrinsically safe, explosion proof, or purged and pressurized electrical equipment: Within 10 feet (3 m) of a cargo tank vent outlet. 04 lights within 10 feet of vent outlets are not rated for Class I, Div 1. Documents you provided on 10APR23 do not prove the lights meet Class I, Div 1. The vessel hazardous area plan you provided on 17APR23 shows lights are located within a hazardous area. Remove or replace the lights. This deficiency must be rectified by 15MAY23.
Action required: 705 - Other - as specified
Due 15 May 2023
Resolved 7 May 2023
Resolution: Vessel rep. sent in satisfactory photos and documentation on new lights that meet the Class 1/Div 1 requirements.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2022 Resolved
When major alterations or major repairs of tank vessel become necessary the work shall be done under the direction of the Officer in Charge, Marine Inspection, and shall be in accordance with the regulations in effect for new construction insofar as possible. The damage to the vessels hull is in the vicinity of the for-peak void, approx. 4x5ft section above the waterline. Temporary repair was performed and a 1/4" doubler plate was utilized to cover the total perimeter to ensure water-tight integrity. Vessel was issued a Permit to proceed (PTP) to Tampa, FL, to discharge cargo (molten sulfur). Upon completion of discharge, the vessel shall proceed directly to Gulf Marine Shipyard in Tampa, FL for permanent repairs to the satisfaction of a USCG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2022
Resolved 29 July 2022
Resolution: C/R Bow insert and accepted ABS report for the Port Bow insert.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 10 July 2019 Resolved
Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Marine Inspector found current test of transfer piping system conducted using air. If vessel is unable to test transfer piping system IAW 33 CFR 156.170(c)(4), vessel must submit alternative testing procedure IAW 33 CFR 156.107.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 15 July 2019
Resolution: Owner provided current LOAC to this office.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 January 2014 Resolved
Renew metallic sheatthed bacle running fore and aft on the port side deck of the vessel and locate within appropriate effective protection per IEEE45 Section 33 for installation in hazardous locations and Section 25 for all other areas per 46CFR111.05-7, 46CFR111.60-5(a)(1), and 46CFR111.105-3.
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 4 February 2014
Resolution: Inspected install of new wire and conduate for wire running fore and aft on the port side deck.
Electrical › Electric Generation Source (service) › Generator
Issued 3 January 2014 Resolved
Prove proper operation of emergency shutdowns of ship service generator per 46CFR111.12-1
Action required: 705 - Other - as specified
Due 3 February 2014
Resolved 4 February 2014
Resolution: Tested independent overspeed shutdown of both ship service generators
Electrical › Electric Supply System (service) › Cable
Issued 3 January 2014 Resolved
Provide new stuffing tube on port navigation light battery box per 46CFR111.60-5
Action required: 705 - Other - as specified
Due 3 February 2014
Resolved 4 February 2014
Resolution: Inspected install of new stuffing tube.
Electrical › Lighting (service) › Outlet Box
Issued 3 January 2014 Resolved
Provide new cover for bow lighting receptacle per 46CFR111.79-1
Action required: 705 - Other - as specified
Due 3 February 2014
Resolved 4 February 2014
Resolution: Inspected install of new cover for lighting receptacle
Electrical › Electrical Distribution System (service) › Cable
Issued 3 January 2014 Resolved
Properly install cable for port, forward heater house light per 46CFR111.60-5
Action required: 705 - Other - as specified
Due 3 February 2014
Resolved 4 February 2014
Resolution: Inspected install of new wire cable to house light
Electrical › Electrical Distribution System (service) › Cable
Issued 3 January 2014 Resolved
Renew cable installation for starboard heater house light per 46CFR111.60-5
Action required: 705 - Other - as specified
Due 3 February 2014
Resolved 4 February 2014
Resolution: Inspected install of new cable for house light
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 3 January 2014 Resolved
Provide proper insulation for heater piping per 46CFR56.04-10(b)
Action required: 705 - Other - as specified
Due 15 July 2014
Resolved 25 March 2014
Resolution: Verified installation of insulation on cargo heater piping manifolds and valves at each cargo tank top. All SAT. Cleared CG-835 issued by Sector Mobile, AL.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 5 January 2012 Resolved
Portside generator found to contain exposed and dead end wiring. Make repairs to electrical installations to ensure protection of crew from electrical hazards in accordance with 46 CFR 111.01-1(b).
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Exposed wire properly dead ended to ensure protection of crew from electrical hazards.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 5 January 2012 Resolved
Operator unable to demonstrate proper low lubricating oil pressure shutdown on port and starboard generators in accordance with 46 CFR 11.12-1(c). Install self Venting Test Valve on sentinel Diesel Protection System in accordance with manufacturer's specifications, and demonstrate proper low lubricating oil pressure shutdown tests on port and starboard generators.
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Witnessed proper low lubricating oil pressure shutdown on port and starboard generators.
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2012 Resolved
Thermal fluid heater found to contain dead end wiring. Make repairs to electrical installations to ensure protection of crew from electrical hazards in accordance with 46 CFR 11.01(b).
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Loose wiring properly dead ended to ensure protection of crew from electrical hazards.
Deck/Cargo › Cargo Stowage › General
Issued 5 January 2012 Resolved
Starboard voids #1 & #6 vent flame screens have openings which could permit the entry of flames. Repair flame screens to ensure voids are properly protected from flame entry in accordance with 46 CFR 32.55-45(a).
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Starboard voids #1 & #6 flame screens have been properly repaired to protect from flame entry.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 5 January 2012 Resolved
Excessive oil accumulation on portside generator fan creating a fire hazard. Ensure oil is removed.
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Excessive oil removed from portside generator fan.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 5 January 2012 Resolved
Portside prime mover radiator leaking fluid. Replace radiator in kind and test. 46 CFR 31.10-17(a)(3)
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Portside prime mover radiator replaced in kind.
Engineering › Diesel Engine (auxiliary) › Block
Issued 5 January 2012 Resolved
Starboard side generator radiator leaking fluid. Replace radiator in kind and test. 46 CFR 31.10-17(a)(3)
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Starboard side generator radiator replaced in kind and properly tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 January 2012 Resolved
Stern navigation light inoperable. Verify/test stern navigation light in accordance with Inland Rules of the Road.
Action required: 705 - Other - as specified
Resolved 5 January 2012
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 5 January 2012 Resolved
Three cargo tank vent headers damaged and inoperable. Replace in kind.
Action required: 705 - Other - as specified
Resolved 2 February 2012
Resolution: Three cargo tank vent headers replaced in kind.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 4 October 2010 Resolved
Demonstrate operation of the thermal fluid heater low expansion tank alarm in the presence of a Coast Guard Marine Inspector per 46 CFR 61.35-3 prior to November 5, 2010.
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 29 October 2010
Resolution: MSU Port Arthur witnessed satisfactory test of low expansion tank alarm. See activity 3880006
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 4 October 2010 Resolved
Renew gasket material for all bolted void covers on the main deck and ensure they are watertight per 46 CFR 42.15-40 prior to November 5, 2010
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 2 November 2010
Resolution: 1DEC2010: Rcv''d e-mail notification that the hatch cover gaskets were renewed on 2NOV2010 by International Ship Repair, Tampa.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 4 October 2010 Resolved
Renew flame screens for diesel fuel tank vents meeting 46 CFR 56.50-85(a)(8) with a single screen of corrosion resistant wire of at least 30 by 30 mesh or two screens of at least 20 by 20 mesh spaced not less than one-half inch nor more than 1.5 inches apart prior to November 5, 2010
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2010
Resolved 29 October 2010
Resolution: MSU Port Arthur verified that all flame screens weet requirements of 46 CFR 56.50-85(a)(8). See Activity 3880006
Engineering › Steam Boiler (auxiliary/waste heat) › Combustion Chamber
Issued 4 October 2010 Resolved
Prepare the thermal fluid heater for the visual inspections required by 46 CFR 61.30-15, internal examination of the combustion chamber for the attending Coast Guard Marine Inspector at next drydock.
Action required: 705 - Other - as specified
Due 28 February 2011
Resolved 16 March 2011
Construction/Loadline › Hull › Weld
Issued 4 October 2010 Resolved
At next drydock further examine and address washed out welds in #4 Starboard Wing tank per 46 CFR 31.10-21(c) and 32.60-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2011
Resolved 16 February 2011
Construction/Loadline › Hull › Hull Plating
Issued 4 October 2010 Resolved
At next drydock further examine the wastage located in #6 Port Void per 46 CFR 31.10-21(c) and 32.60-1.
Action required: 705 - Other - as specified
Due 28 February 2011
Resolved 16 February 2011
Construction/Loadline › Hull › Hull Plating
Issued 19 February 2010 Resolved
Crop and renew damaged areas to original after proceeding to shipyard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2010
Resolution: Damaged areas repaired to satisfaction of ABS and attending USCG marine inspectors.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2010 Resolved
Failure to conduct annual inspection of a tank vessel of 1600GT or more.
Action required: 705 - Other - as specified
Resolved 19 April 2010
Resolution: Vessel conducted satisfactory annual inspection.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 25 November 2008 Resolved
Extensive repairs made to barge at the notch without notification of the local [name withheld] in excess of $300,000. All damage internal in vacinity of notch.
Action required: 705 - Other - as specified
Resolved 25 November 2008
Resolution: CG inspectors noticed vessel drydocked at shipyard. Inspectors inquired and were notified that repairs were being made.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 25 November 2008 Resolved
Barge drydocked without prior notification to the local OCMI.
Action required: 705 - Other - as specified
Resolved 25 November 2008
Resolution: CG Inspectors noticed vessel in drydock at shipyard. Inspectors inquired and were notified that vessel was drydocked for repairs to the notch.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 14 October 2008 Resolved
Replace / repair portable fire extinguisher in gen rm.
Due 14 October 2008
Resolved 14 October 2008
Resolution: Used spare bottle.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 14 October 2008 Resolved
Add type of communication used in the transfer porcedures.
Due 28 October 2008
Resolved 2 November 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 October 2008 Resolved
Remove or mark unused power panel in generator room.
Due 28 October 2008
Resolved 2 November 2009
Deck/Cargo › Holds/Tanks › Ullage
Issued 14 October 2008 Resolved
Stencile "CC" in contrasting color on all cargo domes.
Due 28 October 2008
Resolved 2 November 2009
Stability › Watertight Integrity › General
Issued 26 February 2008 Resolved
Provide repair proposal to permanently repair all wasted/damaged deck expansion joints throughout vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2008
Stability › Watertight Integrity › General
Issued 26 February 2008 Resolved
Examine vsl throughout to ensure there is no further water intrusion compromising the vsl's water tight integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 24 February 2003 Resolved
Stuffing tube loose thru watertight bulkhead from generator space to weather deck..
Condition: Improper/Lack of Maintenance
Due 24 February 2003
Resolved 24 February 2003
Electrical › Electric Generation Source (service) › Generator
Issued 24 February 2003 Resolved
Missing foundation bolt on port generator for TFH.
Condition: Improper/Lack of Maintenance
Due 24 February 2003
Resolved 24 February 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 24 February 2003 Resolved
Label missing.
Due 24 February 2003
Resolved 24 February 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 24 February 2003 Resolved
Emergency shutdown cable worked properly, but the cable handle broke when pulled.
Action required: 705 - Other - as specified
Resolved 24 February 2003
Deck/Cargo
Issued 19 December 2000 Resolved
Conduct operational test on thermal fluid heater to the satisfaction of attending marine inspector.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Accommodation/Occupational Safety
Issued 19 December 2000 Resolved
Replace or demonstrate proper operation of air receiver relief valve to thesatisfaction of attending marine inspector.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Unknown
Issued 19 December 2000 Resolved
RESCENDED
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Engineering
Issued 19 December 2000 Resolved
Test overspeed of stbd cargo pump engine in the presence of marine inspector.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Engineering
Issued 19 December 2000 Resolved
Replace missing metal shield of RAYCOR fuel filter on thermal fluid heater.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Deck/Cargo
Issued 19 December 2000 Resolved
Open thermal fluid heater combustion chamber for internal inspection to thesatisfaction of attending marine inspector.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Electrical
Issued 18 February 2000 Resolved
REPLACE 1 BURNED OUT DECK LIGHT BULB, AFT KING POST, STARBOARD LIGHT.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Fire Fighting
Issued 18 February 2000 Resolved
REPLACE ALL FIRE EXTINGUISHER BRACKETS. EXISTING BRACKETS ARE WASTED AND IN SOME CASES IMPROPER TYPE.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Deck/Cargo
Issued 18 February 2000 Resolved
CONDUCT OPERATIONAL TEST OF THERMAL FLUID HEATER SAFETY FEATURES PER APPROVED AUTOMATION TEST PROCEDURES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Engineering
Issued 18 February 2000 Resolved
REPLACE FLAME SCREENS FOR FUEL OIL VENTS AT AFT CONNECTIONS, PORT AND STARBOARD. SOME HAD HOLES AND ALL WERE IMPROPERLY INSTALLED WITH LARGE GAPS.
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Construction/Loadline
Issued 9 May 1998 Resolved
MAKE PERMANENT REPAIRS TO APPROX 90FT BY 10FT DAMAGE TO SIDESHELL AND ASSOCIATED LONGS, STIFFENERS, AND BULKHEADS IN NO. 1 PORT AFT AND NO.2 PORTFWD WING VOIDS. REPAIRS TO BE COMPLETED TO SATISFACTION OF COGNIZANT [name withheld] CONDITION REPORTS TO BE SUBMITTED TO MSO CORPUS EVERY
Condition: Unknown
Due 9 May 1998
Resolved 9 May 1998
Construction/Loadline
Issued 9 May 1998 Resolved
(CONT'D) 30 DAYS UNTIL PERMANENT REPAIRS ARE COMPLETED AT NEXT DRYDOCK.
Condition: Unknown
Due 9 May 1998
Resolved 9 May 1998
Electrical
Issued 23 February 1998 Resolved
Repair emergency light above generator switchboard.
Condition: Unknown
Due 23 February 1998
Resolved 25 February 1998
Lifesaving
Issued 23 February 1998 Resolved
Remove all flammables from machinery space.
Condition: Unknown
Due 23 February 1998
Resolved 25 February 1998
Construction/Loadline
Issued 26 March 1997 Resolved
MAKE PERMANENT REPAIRS TO 15' OF PORT AFT HAND RAILS. (APPROX 15' FROM PORTSTERN CORNER FWD.)
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.