Records from 2010 to 2025. Most recent: inspection, 8 September 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portBEAUMONT, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
8 September 2025
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8229713
26 August 2025
Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8218529
15 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8019177
7 November 2023
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7814167
30 June 2022
Administrative Inspection · Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7491727
21 June 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7489680
26 August 2021
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7297420
11 July 2020
COI Inspection · Drydock Exam · MTSA Verification · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7003376
19 February 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6911323
21 February 2019
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6629553
26 February 2018
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6361763
13 December 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6055262
12 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6056414
8 December 2015
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5772993
1 April 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5094790
25 February 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5103161
24 February 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5078755
17 February 2015
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5070126
10 February 2015
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5067145
10 February 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5067487
21 January 2015
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5056557
9 December 2013
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4764868
1 March 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4250645
17 November 2010
Hull Examination · Administrative Inspection · MTSA Verification · Initial Construction-Excluding Oversight · Deadweight Survey · Internal Structural Exam · Cargo Tank Internal · Initial Certification
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3893295
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 February 2020
Resolved
Remote quick acting manual shutdown shall be installed on the engines so as to provide a quick and effective means of stopping the engine.
Unable to start port cargo pump prime mover. As a result, attending marine inspector was unable to witness satisfactory operation of the quick acting manual shutdown.
Prior to operating the stbd cargo pump prime mover repairs must be made to the satisfaction of the local OCMI.
46 CFR 32.50-35
Action required: 705 - Other - as specified
Resolved 22 February 2020
Deck/Cargo › Cargo Stowage › General
Issued 10 February 2015
Resolved
Vessel was struck while moored at San Jac Fleeting causing one 4'X36" inset on #2 starboard cargo tank, two 4'X2' insets on #3 starboard cargo tank. Issued CG 835 authorizing one time discharge and to proceed directly to repair facility to make permanent repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2015
Resolved 17 February 2015
Resolution: Both insets were inserted on the cargo tanks.