MAURY USCG vessel records
← All vessels

CROSBY ADMIRAL

Built
1983
Last inspected
10 April 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 10 April 2024
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1997–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8213029
WDF3563
213398
Flag
UNITED STATES
Maury page id
psix-213398

Documentation record

Registered dimensions (L × B × D)113.6 ft × 32.0 ft × 14.1 ft
Registered tonnagegross 175 / net 119
ITC dimensions (L × B × D)114.7 ft × 32.0 ft × 16.0 ft
ITC tonnagegross 397 / net 119
BuilderBOLLINGER MACHINE SHOP & SHIPYARD INC · LOCKPORT, LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it119 - Convention (Subpart B), Net Ton
119 - Regulatory (Subpart C or D), Net Ton
397 - Convention (Subpart B), Gross Ton
175 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LOUISE KIRKPATRICK Freight Barge · MISLE 44817 · 1 July 2006 · activity 2704527AMY E. HEBERT Towing Vessel · MISLE 101518 · 2 July 2000 · activity 46374ZION M FALGOUT Towing Vessel · MISLE 131148 · 2 July 2000 · activity 46374

Inspection history · 24

10 April 2024 Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7893303
5 August 2021 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7277687
29 July 2021 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7271975
14 May 2021 Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7196952
9 April 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7172164
26 December 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6894883
20 May 2019 Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6688565
6 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6502529
7 June 2018 Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6433835
22 October 2014 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5010277
13 November 2013 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4755452
3 November 2010 Industry Initiated Exam · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3884316
7 October 2009 Industry Initiated Exam · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3610435
18 August 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3305657
1 July 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2704527
6 October 2004 Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2215210
17 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2070545
21 January 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1989557
8 January 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1989328
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978420
7 February 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1741315
2 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 46374
19 June 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762741
12 June 1997 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 200144

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2021 Resolved
Plastic fire hose nozzles found at fire stations in engine room. Replace nozzles with approved brass type. cite: 46 CFR 142.325(d)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 26 May 2021
Resolution: fire nozzles replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2021 Resolved
Switchboard is missing approved ASTM type 2 matting. VSL must provide matting in the front and of switchboard. 46 CFR 143.400(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 26 May 2021
Resolution: matting was placed in front of switchboard
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 May 2021 Resolved
There are no steering alarms for the aft operations station. VSL shall install all required alarms per cite. Cite:46 CFR 143.230(b)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 26 May 2021
Resolution: audible and visual alarm was installed in aft operating station
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2021 Resolved
Flame screens throughout VSL were deteriorated. Replace flame screens with approved 30x30 mesh. 46 CFR 143.265(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 26 May 2021
Resolution: flame screens were replaced
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 May 2021 Resolved
VSL does not have the required amount of line throwing appliances for requested international route four(4). CITE: SOLAS 14 III-18
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 26 May 2021
Resolution: vsl has 4 line throwing applicances onboard
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 May 2021 Resolved
VSL does not have the required amount of rocket parachute flares for requested international route twelve (12) CITE: SOLAS 14 III-6.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 26 May 2021
Resolution: vsl has 12 rocket parachite flares
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 14 May 2021 Resolved
VSL needs BNWAS installed for requested international route. CITE: SOLAS 14 V-19.2.2.3.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2021
Resolved 26 May 2021
Resolution: vsl did not have BNWAS installed, changed route to domestic only until system is installed
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 6 August 2018 Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018

Recorded names · 1

DOLPHIN IV (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record