MAURY USCG vessel records Sign in
← All vessels

MARINECO I

MARINECO I is a 1973 mobile offshore drilling unit. The Coast Guard has recorded 91 inspections since 1980, most recently in October 2000, along with 240 deficiencies — 2 with no resolution recorded —.

Records from 1980 to 2000. Most recent: inspection, 23 October 2000.

Built
1973
Last inspected
23 October 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8750857 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-51235

Inspections, by type

…with no type recorded28
…past their stated due date2
Years with a record 20 calendar years (1980–2000)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3372 - Regulatory (Subpart C or D), Net Ton
4581 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCE8416MMSI not assigned · expired · voluntarily equipped · granted 29 March 1994, cancelled 30 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RAINBOW RUNNER Offshore Supply Vessel · MISLE 196932 · 23 October 2000 · activity 77834AMY E. HEBERT Towing Vessel · MISLE 101518 · 2 July 2000 · activity 46374ZION M FALGOUT Towing Vessel · MISLE 131148 · 2 July 2000 · activity 46374CROSBY ADMIRAL Towing Vessel · MISLE 213398 · 2 July 2000 · activity 46374

Inspection history · 91

23 October 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 77834
23 October 2000 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454860
2 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 46374
12 July 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093832
24 May 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 804634
14 April 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788897
21 September 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 804712
5 August 1998 Re-Inspection · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434767
2 August 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 7417
26 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119649
22 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124671
13 March 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106740
9 February 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 774670
27 January 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111083
3 December 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780219
2 October 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1470431
30 September 1997 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414818
13 March 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1106083
4 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087169
20 July 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1190118
13 July 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 871798
10 July 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 882979
5 May 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030750
12 April 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387744
6 December 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173843
8 October 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174832
1 September 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 862265
30 August 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 868493
7 July 1994 Hull Examination · Damage Survey · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401890
2 June 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018371
16 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859986
13 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 859238
27 March 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354638
9 February 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 852480
2 December 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1158627
20 August 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1155835
30 July 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157407
17 June 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962858
30 March 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389635
5 October 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243992
23 July 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950664
4 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942942
27 March 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261398
10 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261122
27 November 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 940164
26 November 1991 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 938049
11 November 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 941104
21 October 1991 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 939933
12 September 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 642496
30 August 1991 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1249634
12 August 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 669302
10 August 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 345298
10 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216343
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238165
7 May 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1223935
30 August 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922406
13 August 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215675
18 July 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915801
11 June 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217556
23 March 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913001
23 January 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916947
21 December 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903790
8 December 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228190
22 November 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234124
10 October 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036315
16 June 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207851
7 June 1989 Drydock Extension · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897515
8 May 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 896517
19 July 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1035804
18 July 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1342031
16 May 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1043826
13 April 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201324
23 March 1988 COI Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1351119
6 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313333
20 May 1987 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1335337
29 September 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319417
17 April 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298838
23 March 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302379
30 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979584
18 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290045
14 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288429
20 October 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282909
1 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282105
2 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280357
22 March 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972497
23 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964881
5 November 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968205
12 August 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965890
6 July 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275547
17 March 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271430
10 April 1980 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275967

Deficiency record · 240

Deck/Cargo
Issued 23 October 2000 No resolution recorded
Use of main crane prohibited until inspected by a certified crane inspectorand results accepted by cognizant OCMI.
Condition: Unknown
Due 25 April 2001 — due date passed with no resolution recorded
Lifesaving
Issued 5 August 1998 No resolution recorded
Provide lifeboat for lifeboat davit # 3 and weight test same.
Condition: Unknown
Due 31 December 1999 — due date passed with no resolution recorded
Lifesaving
Issued 5 August 1998 Resolved
REPAIR EXHAUST LEAK ON NO 2 LIFEBOAT.
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Fire Fighting
Issued 5 August 1998 Resolved
PROVIDE ACTIVATION INSTRUCTIONS FOR C02 ENGINE SHUTDOWN SYSTEM AT BOTTLE LOCATION.
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
PROVIDE NON CONDUCTING BLANK FOR L101/120V LIGHTING PANEL IN RECREATION ROOM. 46CFR111.75
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
ADD ADDITIONAL EMERGENCY LIGHT IN MACHINERY ROOM OVER WEATHERTIGHT DOOR ANDSTAIR ACCESS TO PUMPS TO ILLUMINATE AREA. PER 46CFR112
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Engineering
Issued 5 August 1998 Resolved
CONDUCT HYDROSTATIC TEST TO 1.5 MAWP AND MARK SAME ON FUEL TRANSFER HOSE ASPER 33CFR155.800
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
PROVIDE NON CONDUCTING BLANK FOR L102-1 120 VOLT LIGHTING PANEL IN MACHINERY ROOM. 46CFR111.12
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
REPAIR/REPLACE SPRING LOADED OUTLETS/COVERS ON STARBOARD SIDE AFT DRILL FLOOR. 46CFR111.6019
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
LABEL VENTILATION SHUTDOWN SWITCH ON DRILL FLOOR IN DRILLERS SHACK.
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
PROVIDE NON-CONDUCTING BLANK FOR MAIN FEEDER PANEL IN MACHINERY ROOM. 46 CFR 111.12
Condition: Unknown
Due 7 August 1998
Resolved 12 August 1998
Electrical
Issued 5 August 1998 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARM AND OVERSPEED FOR EMERGENCY GENERATOR. 46CFR112.50
Condition: Unknown
Due 5 August 1998
Resolved 12 August 1998
Construction/Loadline
Issued 2 October 1997 Resolved
CONDUCT SWIM-BY OF PONTOONS TO COMPLETE DRYDOCK CREDIT.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Documentation
Issued 2 October 1997 Resolved
PRIOR TO CONDUCTING DRILLING OPERATIONS PROVIDE [name withheld] WITH PRELIMINARY RESULTS OF INCLINING CONDUCTED ON OR ABOUT 03 OCT 1997.
Condition: Unknown
Due 7 October 1997
Resolved 4 March 1998
Lifesaving
Issued 2 October 1997 Resolved
PROVE PROPER OPERATION OF WATERSPRAY SYSTEM FOR #3 LIFEBOAT.
Condition: Unknown
Due 5 October 1997
Resolved 4 March 1998
Lifesaving
Issued 12 April 1995 Resolved
Conduct annual servicing of the two (2) lifeboats that expired in FEB95.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 12 April 1995 Resolved
Properly repair door and combing from mud pump room to sack room.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 12 April 1995 Resolved
Properly repair vent closure located port stern for the compressor room.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 12 April 1995 Resolved
Properly repair watertight doors to the engine room & emergency gen. room to allow proper closure (new hinge pins) and any other door as needed.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 12 April 1995 Resolved
Provide proper gloves for both fireman's outfits.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995 Resolved
Provide sea anchors in lifeboats #1 & 2 and thirty-five (35) rations in lifeboat #3.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 12 April 1995 Resolved
Renew current lights with non-expired units on fifty-two (52) life jackets.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Documentation
Issued 7 July 1994 Resolved
SUBMIT COPIES OF THE FOLLOWING TO [name withheld]: ALL NDT REPORTS AND NDT OPERATORS QUALIFICATIONS AND PICTURES OF ALL DAMAGE.
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Accommodation/Occupational Safety
Issued 27 March 1994 Resolved
RENEW GASKETS ON BOTH FREEZER & CHILL BOX DOORS, REPAIR REFRIGERATION MACHINERY TO MAINTAIN PROPER BOX TEMPS. (-10 to 0 deg F/FREEZE BOX) (36-40 deg F/CHILL BOX).
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Accommodation/Occupational Safety
Issued 27 March 1994 Resolved
PROPERLY REPAIR UPSTAIRS A/C UNIT IN QUARTERS.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Lifesaving
Issued 27 March 1994 Resolved
RENEW (2) SOLAS APPROVED ORANGE SMOKE SIGNALS IN CAPSULE #2 (EXP 1-94).
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Deck/Cargo
Issued 27 March 1994 Resolved
FAX COPY OF ABS 5YR. CRANE TEST TO [name withheld], LA -@[phone withheld]
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Accommodation/Occupational Safety
Issued 27 March 1994 Resolved
REPAIR/RENEW ALL WASTED HAND RAILS, LADDER THREADS AND CATWALK GRATES AS NEEDED.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Construction/Loadline
Issued 27 March 1994 Resolved
RENEW ALL MISSING STUDS AND NUTS ON AFT PORT THRUSTER ROOM , MAIN DECK HATCH.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Accommodation/Occupational Safety
Issued 27 March 1994 Resolved
PROPERLY CLEAN GAYLORD HOOD SYSTEM, GALLEY DECK UNDER/AROUND ALL EQUIPMENT,AND ALL GALLEY EQUIPMENT. INSURE PROPER USE OF DISHWASHER TO SANITIZE EATING/COOKING UTENSILS.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Navigation
Issued 27 March 1994 Resolved
REPAIR/REMOVE ABANDONED S/P PHONES ON MAIN DECK P/S BOW AREAS.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Deck/Cargo
Issued 27 March 1994 Resolved
RENEW PIPING ON TOP OF GUIDELINE TENSIONER AIR/OIL RESERVOIR BOTTLES PORT AND STBD
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Unknown
Issued 27 March 1994 Resolved
PROPERLY REPAIR TWO (2) AIR COMPRESSORS FOR THE DRILL STRING TENSIONING SYSTEM, CONDUCT RELIEF VALVE POP TEST/INTERNAL ON TWO REMAINING AIR RECEIVERS.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Construction/Loadline
Issued 27 March 1994 Resolved
RENEW/REPAIR WASTED HATCH COAMING ON CEMENT ROOM HATCH-STBD BOW MAIN DECK.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Accommodation/Occupational Safety
Issued 27 March 1994 Resolved
PROPERLY REPAIR HOLE IN MAIN DECK HEAD AND ADJUST ALL WATERTIGHT DOORS ON RIG.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Lifesaving
Issued 27 March 1994 Resolved
RENEW CONDENSED MILK IN ALL LIFE BOATS OR REPLACE WITH RATIONS TO BRING UP CALORIE TOTAL TO 5000 PER MAN.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Fire Fighting
Issued 27 March 1994 Resolved
PROVIDE HYDRO DATE CERTIFICATE ON B-V UNIT ON HELO DECK, DUE TO RUST AND SCALE OR RECONDITION AND HYDRO.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Fire Fighting
Issued 27 March 1994 Resolved
PROVIDE CERTIFICATION OF HYDRO ON ALL CO2 FLEX LOOPS OR RENEW ALL FLEX LOOPS.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Engineering
Issued 27 March 1994 Resolved
RENEW BROKEN (OOC) HOT WATER HEATER, WITH PROPER <100PSI/210 deg F PRESSURE/TEMPERATURE RELIEF VALVE.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Lifesaving
Issued 27 March 1994 Resolved
RENEW ALL WASTED SHACKLES, THIMBLES, TAG LINES, CLEVIS PINS, CONTROL CABLESON DAVIT LAUNCHED LIFERAFTS, PROVIDE CERTIFICATION OF TEST ON SELF RELEASING HOOKS.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Lifesaving
Issued 27 March 1994 Resolved
CONDUCT WEIGHT TEST OF LIFEBOAT (44 MAN) AND #1 AND #2 CAPSULES (28 MAN EACH) AND OPERATE WEATHER PERMITTING.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Deck/Cargo
Issued 27 March 1994 Resolved
RENEW/REPAIR PIPE WIRE RUNS FOR #1/#2 ANCHOR WINCH CONTROLLERS ON MAIN DECK.
Condition: Unknown
Due 13 May 1994
Resolved 13 May 1994
Deck/Cargo
Issued 27 March 1994 Resolved
RENEW ASME APPROVED 2400 PSI RELIEF VALVES (6 EACH) ON HIGH PRESSURE AIR RECEIVERS FOR MOTION COMPENSATOR SYSTEM - VALVES AND COUPLINGS ARE WASTED AND TO BE RENEWED - COUPLINGS TO BE ASME 5000 PSI RATED.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Fire Fighting
Issued 30 March 1993 Resolved
REINSTALL CO2 BOTTLE FOR FIXED FIRE EXTINGUSHER SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Electrical
Issued 30 March 1993 Resolved
PROPERLY SPLICE AND SECURE LOOSEJ WIRES IN CRANE PEDESTAL BASE (PORT SIDE).
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
INSTALL OR REPAINT "NO SMOKING" SIGNS IN DESIGNATED CRANE REFUELING STATIONS (ENGLISH AND PORTUGESE).
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
CONDUCT ANNUAL SERVICE TEST ON BOTH BF GOODRICH DAVIL LAUNCHED LIFERAFTS ATA COAST GUARD APPROVED FACILITY IN THE PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Fire Fighting
Issued 30 March 1993 Resolved
PROVIDE 2 1/2" FIRE HOSE AT FIRE STATION #20. PROVIDE TEMPORARY 1 1/2" HOSE UNTIL REPLACEMENT INSTALLED.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Engineering
Issued 30 March 1993 Resolved
RENEW FINAL SECTION OF FUEL TRANSFER HOSE.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
REPLACE DEFECTIVE METHANE GAS DETECTORS IN MUD SHAKER AND PIT AREA.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Engineering
Issued 30 March 1993 Resolved
RENEW CRANE DIESEL FUELING HOSES WITH FACTORY TYPE (NO HOSE CLAMPS)
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Engineering
Issued 30 March 1993 Resolved
INSTALL FLAME SCREEN ON ENGINE OIL TANK UNDER PORT CRANE (2ND VENT) WITH 30X 30 MESH WIRE.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Engineering
Issued 30 March 1993 Resolved
INSTALL FLAME SCREEN (30 X 30 MESH) FOR BOX GIRDER CONTAINMENT UNDER PORT CRANE, ON ALL HYDROCARBON CONTAINING TANKS IN TANK RACKON UPPER DECK PORT SIDE.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Documentation
Issued 30 March 1993 Resolved
PROVIDE ORIGINALS OF ALL LICENSES FOR ALL REQUIRED PERSONS ON BOARD.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #2: ASPIRIN (100 TABS), CLEAN OIL FROM BILGES, RENEW EXHAUST FLAPPER.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #1: EYE IRRIGATION (1ST AID KIT), ASPIRIN (100 TABS), RENEW BILGE AND SPRINKLER SYSTEM HOSES, CLEAN OIL OUT OF BILGES, PROVIDE 12 PROVISIONS (3600 CAL/PERSON), RENEW EXHAUST FLAPPER.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Accommodation/Occupational Safety
Issued 30 March 1993 Resolved
CROP AND RENEW WALKWAYS (CATWALKS) AND HANDRAILS AROUND CRANES.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #3: ELEVEN (11) CANS OF CONDENSED MILK, CLEAN OR REPLACE PILOT'S WINDOW, CLEAN SAND, WATER, AND OIL FROM BILGES.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Fire Fighting
Issued 30 March 1993 Resolved
SERVICE FIRE EXTINGUISHERS IN ACCORDANCE WITH EXTINFOGO LTDH. REPORT DATED 15MAR93.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
CLEAN ALL GENERAL ALARM BELL PLACARDS OF PAINT OVERSPRAY AND STENCIL IN PORTUGESE AND ENGLISH.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Lifesaving
Issued 30 March 1993 Resolved
PROVIDE PROPERLY RATED SHACKLE BETWEEN LIFERAFT DAVIT FALL AND RELEASE HOOK. NEW SHACKLE SHOULD BE 3 TON 5/8". (CONTACT INSTALLER OF LIFERAFT SYSTEM).
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Accommodation/Occupational Safety
Issued 5 October 1992 Resolved
CONDUCT INTERNAL INSPECTION R/V RELIEF TEST FOR 2400 LBS AIR TEMPERATURE RECEIVERS ON OR BEFORE NEXT DRYDOCK.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Deck/Cargo
Issued 27 March 1992 Resolved
PROVIDE 30X30 WIRE MESH OR EQUIV FOR VENTS IN PAINT LOCKER AND FLAMABLE STAWAGE LOCKERS. 46 CFR 90.05
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 27 March 1992 Resolved
PROVIDE 7 ADDITIONAL FLAIRS FOR VESSEL PYRO. 46 CFR 94.90
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Accommodation/Occupational Safety
Issued 27 March 1992 Resolved
CONDUCT INTERNAL INSPECTION R/V RELIEF TEST FOR 2400 LBS AIR TEMPERATURE RECEIVERS ON OR BEFORE NEXT DRYDOCK.
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Lifesaving
Issued 27 March 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 March 1992
Resolved 27 March 1992
Documentation
Issued 27 March 1992 Resolved
PROVIDE ON BOARD THE LATEST HAZARD LOCATION PLAN AND LETTER DATED. 46 CFR 107.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Electrical
Issued 27 March 1992 Resolved
REMOVE DEADENDED CABLE THROUGHOUT VESSEL. 46 CFR 107.231
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Electrical
Issued 27 March 1992 Resolved
DEMONSTRATE PROPER OPERATION OF THE #1 GENERATOR
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Electrical
Issued 27 March 1992 Resolved
LINE ALL BATTERY BOXES WITH LEAD AS NEEDED IE. EMERG GEN BATTERY BOX
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Navigation
Issued 27 March 1992 Resolved
REPAIR DAMAGE TO STARBOARD NAVIGATION LIGHT SCREEN AND PAINT MAT BLACK (NO GLOSS) 46 CFR 107.231
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Construction/Loadline
Issued 27 March 1992 Resolved
PROVIDE CORRECT HINGE PINS FOR WATERTIGHT DOORS 46 CFR 107.231.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Documentation
Issued 27 March 1992 Resolved
PROVIDE A DESIGNATED PERSON IN CHARGE LETTER. 46CFR109.107
Condition: Unknown
Due 30 April 1992
Resolved 16 April 1992
Construction/Loadline
Issued 30 August 1991 Resolved
PRESENT FOR INSPECTION THE LOWER PORT AND STARBOARD PONTOON HULLS.
Condition: Unknown
Due 30 August 1991
Resolved 30 August 1991
Navigation
Issued 10 August 1991 Resolved
VESSEL ENTER PORT WITHOUT NOTIFING THE CAPTAIN OF THE PORT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Lifesaving
Issued 7 May 1991 Resolved
RENEW AND TEST WINCH CABLES FOR #3 LIFEBOAT AND DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Electrical
Issued 7 May 1991 Resolved
REPAIR/REPLACE 440 VAC BREAKER PANEL IN MACHINE SHOP.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Fire Fighting
Issued 7 May 1991 Resolved
PROVE OPERATION OF FIXED FIRE EXTINGUISHING SYSTEM-ALARMS, SHUTDOWNS AND BLOWDOWN.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Lifesaving
Issued 7 May 1991 Resolved
PROVIDE LIFEBOAT RADIO PRIOR TO FOREIGN VOYAGE.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Lifesaving
Issued 7 May 1991 Resolved
PROVIDE CONDENSED MILK (1 LB PER PERSON) PRIOR TO FOREIGN VOYAGE.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Electrical
Issued 7 May 1991 Resolved
PROVE PROPER OPERATION OF #2 AND #3 GENERATOR REVERSE POWER RELAYS, OVERSPEED AND LOW LUBE OIL TRIPS.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Deck/Cargo
Issued 7 May 1991 Resolved
PROVE OPERATION OF TENSIONER AND RECEIVER RELIEF VALVES.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Unknown
Issued 18 July 1990 Resolved
SUBMIT A REPAIR PROPOSAL FOR THE PITTING IN WAY OF THE VERTICLE DIAGONAL (INBOARD) STARBOARD SIDE THIRD TRUSS AREA IS ON FORWARD SIDE ABOUT 10-15 FT BELOW HORIZONTAL GIRDIR NEAR WELD SEAM.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Lifesaving
Issued 23 March 1990 Resolved
REPAIR INBOARD LIMIT SWITCH TO BOAT #2.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
RE-ADJUST BOTH LIMIT SWITCHES ON #1 CAPSULE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
REPLACE RING BUOY STBD SIDE FOWARD.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990 Resolved
REMOVE HOLD OPEN DEVICE ON FUELING STATION STBD CRANE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Navigation
Issued 23 March 1990 Resolved
INSTALL A CAP ON THE SCREW TOP JUCTION BOX FOR THE HYDRAULIC UNIT IN THE ENGINEROOM FWD.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Fire Fighting
Issued 23 March 1990 Resolved
CORRECT THE CO2 ROOM INSTRUCTIONS FOR THE CO2 SYSTEM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Accommodation/Occupational Safety
Issued 23 March 1990 Resolved
CONDUCT INTERNAL EXAMS OF ALL TENSIONER BOTTLES IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
INSTALL A LOSS OF PURGE ALARM IN THE DRILLERS VIEW (OR AUIBLE) ON THE VISUALLOGGER ELECTRONICS BOXES (TOTCO)
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
POUR THE EYS FITTING ON THE RENTAL CENTRIFUGE IN THE MUD PIT AREA.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990 Resolved
INSTALL A GUARD AROUND THE ROTATING SHAFT ON THE RENTAL CENTRIFUGE IN THE MUD PIT AREA.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
INSTALL A GENERAL ALARM BELL IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
REPAIR THE GROUND IN THE CELLAR DECK EMERGENCY LIGHT CIRCUIT BREAKER SYSTEM. (ELO)
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
INSTALL A REMOVE FUEL SHUT OFF IN THE LINE FOR THE EMERGENCE GENERATOR.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Accommodation/Occupational Safety
Issued 23 March 1990 Resolved
CLEAN THE GALLEY EXHAUST BY THE HELO DECK.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
INSTALL THE GLASS COVERS IN THE EMERGENCY SHUT OFFS IN THE SCR ROOM AND THELOWER QUARTERS.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 23 March 1990 Resolved
PROVIDE RELIEF VALVES FOR ALL DECK WINDLASS AIR RECEIVERS NOT TO EXCEED MAXIMUM ALLOWABLE WORKING PRESSURE (MAWP)
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
PAINT ALL LIFE RINGS "INTERNATIONAL ORANGE".
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
REPAIR FWAT LT. ON RING BUOY PORT SIDE FOWARD BY #1 BOAT.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
REPAIR GENERAL ALARM BELL STBD FORWARD BOW ON FRONT OF DECK HOUSE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
REPAIR STARTER #1 CAPSULE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
REPLACE RING BUOY PORT SIDE FORWARD AFT OF DECK HOUSE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
TIGHTEN UNION ON EXHAUST TO #3 LIFEBOAT. CLEAN OUT SAND.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
REMOVE THE EXCESS VENT SWITCH IN THE SCR ROOM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
RE-CHARGE 2 OF THREE AIR BOTTLES IN #3 BOAT.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Lifesaving
Issued 23 March 1990 Resolved
PROVIDE BOARDING LADDER #1 AND #2 BOAT.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
INSTALL A LOSS OF PURGE ALARM ON THE DRAWWORKS CONSOLE THAT SENSES PRESSURE OR FLOW IN THE CONSOLE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
SHOW PROOF THAT THE SPERRY SUN HOLE DIRECTION INDICATOR IS INTRINSICALLY SAFE OR INSTALL A PURGE WITH LOSS OF PURGE ALARM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
SHOW PROOF THAT THE TOTCO VISUALLOGGER IS INTRINSICALLY SAFE OR INSTALL A PURGE WITH LOSS OF PURGE ALARM.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
MOVE THE LOSS OF PURGE ALARM FOR THE TOTCO DATA MONITOR SO IT IS IN VIEW OFTHE DRILLER.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
INSTALL CLASS 1 DIV II FITTINGS ON THE ROTARY RPM AND PUMP STROKE GAUGES. MAKE A PROPER REPAIR TO THE SPLICE FOR THE CABLE TO THE LEFT PUMP STROKE GAUGE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
SHOW PROOF THAT THE TOTCO ALARM BOX BEHIND THE DRAWWORKS CONSOLE IS INTRINSICALLY SAFE OR INSTALL A PURGE WITH LOSS OF PURGE ALARM IN THE DRILLERS VIEW (OR AUDIBLE)
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Electrical
Issued 23 March 1990 Resolved
BAND THE ELECTRIC CABLES OVER THE AUXILIARY MACHINERY ROOM POUR WITH CORROSION RESISTANT METAL AT LEAST 5/8" WIDE.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Accommodation/Occupational Safety
Issued 23 March 1990 Resolved
CONDUCT RELIEF VALVE POP OFF TESTS FOR THE TENSIONER BOTTLES IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTIOR.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Accommodation/Occupational Safety
Issued 23 March 1990 Resolved
CONDUCT INTERNAL EXAM OF THE CELLAR DECK AIR RECIEVER IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Accommodation/Occupational Safety
Issued 23 March 1990 Resolved
CONDUCT RELIEF VALVE POP OFF TEST FOR THE CELLAR DECK AIR RECIEVER IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Construction/Loadline
Issued 23 January 1990 Resolved
SUBMIT A REPAIR PROPOSAL FOR THE PITTING IN WAY OF THE VERTICAL PLAGONAL (INBOARD) STBD SIDE THIRD TRUSS. AREA IS ON FORWARD SIDE ABOUT 10-15 FT BELOW HORIZONIAL GIRNER NEAR WELD SEAM.-MICP,P
Condition: Unknown
Due 23 January 1990
Resolved 23 January 1990
Construction/Loadline
Issued 22 November 1989 Resolved
REPAIR THE INBOARD VERTICAL DIAGONAL FROM THE STBD SIDE BOX GIRDER#3 TRUSS FOR VISUAL EXTERNAL INSPECTION AND NOT IF NECESSARY IN THE WAY OF THE BREAKCOOLING WATER DISCHARGE ONTO THE DIAGONAL.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 22 November 1989 Resolved
LABEL LIGHTS AND ALARMS IN BALLEST CONTROL ROOM.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
SUBMIT FOR APPROVAL TO [name withheld] LOCATION DRAING INCLUDE REQUIRED PURGING OF MUD PUMP ROOM TO THE MAIN STATUS AS UNCLASIFIED AREA.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
PROVIDE POSITIVE PRESSURE PURGE OF MUD PUMP ROOM IN ACCORDANCE WITH NFPA 496 AND 46CFR 111.105-33 3(I) (II) (III).
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
PROVIDE PURGE CABINET FOR SONAT DIGITALREMOT READ OUT LOCATED AT DRILLERS CONSOLE.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 22 November 1989 Resolved
REPLACE OR REMOVE NON- EXPLOSION PROOF PITONE WITH A TYPE APPROVED FOR CL IDV II AREA LOCATED PORT SIDE PIPE RACK DECK BENEATH DRILL FLOOR.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Fire Fighting
Issued 22 November 1989 Resolved
MAKE REPAIR AS NECESSARY TO THE TOPSIDE FIRE MAIN PIPING WICH HAS BEEN WASTED BY WEATHER AFTER REPAIRS, HYDROSTATIC TEST OF PIPING SYSTEM MUST BE CONDUCTED AND WITTNESSED BY A MARINE INSPECTOR.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 22 November 1989 Resolved
REPAIR THE REMOTE #6 PORT SIDE DRILL WATER VALVE.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 22 November 1989 Resolved
REPLACE THE STBD. SIDE SAE CHEST CROSSOVER VALVE.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Construction/Loadline
Issued 22 November 1989 Resolved
REPAIR THE BALLEST PIPING IN THE PORT AND STBD AFT PUMPING ROOMS. WELDS LEAKING IN THE VERTICAL PIPING AND AT THE INTERSECTIONOF THE VENT TO THE HORIZONTAL #1 BALLSET PUMP IN THE PORT PUNP ROOM.
Condition: Unknown
Due 22 November 1989
Resolved 22 November 1989
Electrical
Issued 8 May 1989 Resolved
STRIP BACK CABLES FOR BLOWER CONTROLLER IN MUD WEIGHING ROOM IN EYS'S AND DOOR EYS'S. ITEMS SHALL BE COMPLETED PRIOR TO DRILLING.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Electrical
Issued 8 May 1989 Resolved
STRIP CABLES AND POUR EYS FITTINGS FOR 2 PAINT LOCKERS. MAKE PROPER ELECTRICAL CONNECTIONS IN JUNCTION BOX ON UPPER DECK.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Electrical
Issued 8 May 1989 Resolved
REPAIR GENERAL ALARMS IN ENGINE ROOM, SACK ROOM AND DRILL FLOOR.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Fire Fighting
Issued 8 May 1989 Resolved
RENEW THE EXISTING PROXIMATY FIRE SUITS WITH APPROPRIATE FIREMEN SUITS. 3/4 TURNOUT JACKET WITH HIGH BOOTS AND FIREMEN HAT IS ACCEPTABLE AS DISCUSSED WITH BARGE CAPTAIN. (REQUIREMENT WAS TO BE COMPLIED BY 08JUN89)
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Deck/Cargo
Issued 8 May 1989 Resolved
PROVIDE CALCULATION FOR PROOF THAT DAMAGED LOW PRESSURE ACCUMULATOR ON #2 RISER TENSIONER MEETS ASME AS IS. IF NOT, REPAIR OR RENEW AS NEEDED.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Deck/Cargo
Issued 8 May 1989 Resolved
NDT AREA OF DAMAGED LOW PRESSURE ACCUMULATOR ON #2 RISER TENSIONER IF ASME CALCULATIONS SHOW THAT THE PRESSURE VESSEL IS STILL SERVICABLE.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Accommodation/Occupational Safety
Issued 8 May 1989 Resolved
MAKE PERMENANT REPAIRS TO MARINE SANITATION DEVICE TANK.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Engineering
Issued 8 May 1989 Resolved
INSTALL FLAME SHIELDS ON RACOR FILTERS FOR DIESEL FUEL SYSTEM ON #1, #2 AND#3 DIESEL GENERATORS.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Electrical
Issued 8 May 1989 Resolved
INSTALL APPROVED BATTERY CABLE CONNECTORS FOR THOSE CLAMP TYPE CONNECTORS IN THE GENERAL ALARM BANK, EMERGENCY DIESEL GENERATOR START BANK.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Electrical
Issued 8 May 1989 Resolved
REMOVE CABLE SPLICES IN SOUND POWERED TELEPHONE CHORDS THROUGH OU THE VESSEL.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Electrical
Issued 8 May 1989 Resolved
INSTALL A VISIBLE OR AUDIBLE PURGE ALARM FOR THE DRILLER'S CONSOLE THAT SENSES PRESSURE LOSS IN THE PANEL. ITEM SHALL BE COMPLETED PRIOR TO DRILLING.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Electrical
Issued 8 May 1989 Resolved
RELABEL REMOTE CAMERA PURGE ALARM LIGHTS ON MONITOR ON DRILL FLOOR AND ADJUST SO THAT THEY ARE EASILY SEEN BY THE PERSON AT THE DRILLER'S CONTROL.ITEMS SHALL BE COMPLETED PRIOR TO DRILLING.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Lifesaving
Issued 16 May 1988 Resolved
REPAIR FRACTURE IN FIBERGLASS, LIFEBOAT #3, LOCATED STARBOARD SIDE FORWARD OF HATCHES IN WAY OF GUNWALE.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Lifesaving
Issued 23 March 1988 Resolved
LAUNCH AND OPERATE ALL SURVIVAL CAPSULES IN THE WATER.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Navigation
Issued 23 March 1988 Resolved
REPAIR FOG HORN AUTOMATIC CONTROL.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Lifesaving
Issued 23 March 1988 Resolved
REPAIR COMPASS IN #1 CAPSULE.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Unknown
Issued 20 May 1987 Resolved
CONDUCT A FIRE/BOAT DRILL IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Unknown
Issued 20 May 1987 Resolved
COMPLETE THE UNDERWATER SURVEY OF HULL STRUCTURE TO THE SATISFACTION OF THECOGNIZANT OCMI PRIOR TO THE COMMENCEMENT OF DRILLING OPERATIONS.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Lifesaving
Issued 20 May 1987 Resolved
REPAIR/RENEW AS NECESSARY THE ENGINE EXHAUST PIPE TO THE MOTOR LIFE BOAT.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Construction/Loadline
Issued 29 September 1986 Resolved
CROP AND RENEW WASTED SALT WATER PIPING PORT PUMP ROOM.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Construction/Loadline
Issued 29 September 1986 Resolved
MAKE OPERABLE THE QUICK ACTING WATER TIGHT DOOR LOCATED MAIN DECK, PORT SIDE, AFT (BALLAST CONTROL RM AREA).
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Fire Fighting
Issued 29 September 1986 Resolved
CROP AND RENEW WASTED FIRE MAIN PIPING, PORT SIDE AFT, MAIN DECK OUTSIDE COMPRESSOR ROOM.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Construction/Loadline
Issued 29 September 1986 Resolved
REPLACE MISSING NUTS ON FLUSH HATCH COVER LOCATED MAIN DECK, PORT SIDE AFT.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Documentation
Issued 29 September 1986 Resolved
CLEAN AND REPAINT LOADLINE PLIMSOL MARKING ON THE PORT AND STBD SIDES.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Construction/Loadline
Issued 29 September 1986 Resolved
REPAIR WASTED COMBING BELOW WATER TIGHT DOOR, PORT SIDE, FWD MAIN DECK.
Condition: Unknown
Due 29 September 1986
Resolved 29 September 1986
Deck/Cargo
Issued 23 March 1986 Resolved
CONDUCT A SATISFACTORY HYDROSTATIC TEST OF THE FEEL TRANSFER HOSE ON STBD/ PORT OR REPLACE WITH NEW HOSE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Deck/Cargo
Issued 23 March 1986 Resolved
REPAIR/REPLACE DELERIOCATED LANDING/DECK AREA ON STARBOARD CRANE. LOCATED AT THE TOP OF THE LADDER.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
PROVIDE EVIDENCE THAT HYDRO T.V. CAMERA ON DRILL FLOOR N APPROVED FOR A CLASS I, DIV II AREA OR REMOVE FROM RIG. CALSO PURGE ALARM IS INOPRATIVE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
REPLACE INOPERATIVE PRESSURE GAGE ON DRILLER'S CONSOLE LOSS OF PURGE ALARM AIR SUPPLY SYSTEM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Navigation
Issued 23 March 1986 Resolved
MAKE OPERATIVE MAST AND STERN LIGHTS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
REMOVE THE SPEAKER FROM DRILLER'S CONSOLE OR REPLACE WITH ON APPROVED SPEAKER THAT IS DESIGNATED FOR A CLASS I, DIVISION II AREA.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
MAKE OPERATIVE THE LOSS OF PURGE ALARM ON DRILLER'S CONSOLE AND TEST IN PRESENCE OF A USCG INSPECTOR.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Deck/Cargo
Issued 23 March 1986 Resolved
PROVIDE ARI HAND SIGNAL CHART FOR BOTH CRANES.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVIDE SECURING PINS AND/OR ADEQUATE MEANS TO SECURE VENT CLOSURES.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
MAKE OPERATIONAL THE EMERGENCY BILGE CROSS CONNECT HAND OPERATION WHEEL IN THE PORT BALLAST PUMP ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
MAKE OPERATIONAL THE HAND WHEEL FOR THE CROSSOVER BALLAST PUMP VALVE IN THEPORT BALLAST PUMP ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
PROPERLY MOUNT ELECRIC JUNCTION BOX FOR THE CROSS OVER DRILL WATER REMOTELYOPERATED VAVLE IN THE PORT BALLAST PUMP ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
REPAIR LEAK IN THE PIPE TO FLAMGE WELDED JOINT. SALT WATER PUMP DISCHARGE PIPING IN THE PORT BALLAST PUMP ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
MAKE OPERATIONAL THE LOW LUBE OIL ALARM FOR THE EMERGECY GENERATOR.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Construction/Loadline
Issued 23 March 1986 Resolved
PROVIDE ENGINEERING DATA TO SUPPORT THE INSTALLATION OF THE STOP VALVE IN THE POTABLE WATER SUPPLY TO THE "KOOMEY" UNIT.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Fire Fighting
Issued 23 March 1986 Resolved
PROVIDE A MEANS THE BREAK GLASS FOR CO2 FLOODING SYSTEM LOCATED ON THE PAINT LOCKER.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Fire Fighting
Issued 23 March 1986 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR EACH FIREMAN'S OUTFIT: A NON-CONDUCTIVEGLOVES (RUBBER) 2) SPARE BATTERIES 3) RUBBER BOOTS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Fire Fighting
Issued 23 March 1986 Resolved
PROVIDE TWO UL/FM APPROVED OXYGEN/EXPLOSIVE METERS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Fire Fighting
Issued 23 March 1986 Resolved
CONDUCT HYDROSTATIC TEST ON THREE OF THE AIR BOTTLES FOR THE FIREMAN'S OUTFIT (SCBA).
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
EPIRB TO BE TESTED AND LOGGED.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
NUMBER OF CAPSULE TO BE STENCILED ON CAPSULE #1 AND #2.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
PROVIDE LANTERN OR OTHER ACCEPTABLE INTERIOR LIGHTING FOR LIFEBOAT #3. ALSOPOST APPROVED LIFESAVING SIGNAL CHART.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVIDE RELIEF VALVES ON HOT WATER HEATERS SET AT LESS THAN 100 PSI AND LESS THAN 200F OR/OPEN FOR INTERNAL INSPECTION.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
REPAIR INOPERATIVE WATER LIGHT LOCATED ON THE MAIN DECK, STERN.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROPERLY SECURE VENT COVER GASKET LOCATED ON PORT SIDE OUTSIDE MACHINERY SPACE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Lifesaving
Issued 23 March 1986 Resolved
WEIGHT TEST THE DAVIT LAUNCH RAFT HOOK AND FALLS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Lifesaving
Issued 23 March 1986 Resolved
PROVIDE A SECOND DAVIT LAUNCH LIFERAFT AS PER COI. REDUCE MANNING TO 62 UNTIL LIFERAFT RETURNS FROM BEING SERVICED.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVE SATISFACTORY OPERATION OF THE RELIEF VALVE ON THE FRESH WATER PRESSURE TANK(S) LEFT HAND FRESH WATER PRESSURE TANK RELIEF VALVE IS PLUGGED. PROVE SATISFACTORY OPERATION OF THE RELIEF VALVE ON THE SANITARY PRESSURE TANK.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVIDE WEDGES/BLOCKING FOR BATTERIES TO CASE, EMERGENCY GENERATOR STARTING
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
MAKE OPERABLE THE REMOTE VENTILATION SHUTDOWN FOR THE SCR AND GENERATOR ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
PROVIDE COVER FOR ELECTRICAL BOX "LB" CONDUCT TO THE LUBE OIL SUMP, PISTON AIR COMPRESSOR.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
OPEN AND EMPTY FOR INTERNAL INSPECTION THE BAYRITE TANKS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVIDE RELIEF VALVES FOR CEMENT TANKS SET AT 40 PSI WITH A HAND RELIEVING DEVICE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
REPLACE BELL HOUSING ,FAN GUARD, ON TWO PUMP MOTORS REPLACE BELL HOUSING, MUD PITS. FINGER GUARDS BROKEN OUT.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
TIGHTEN BATTERY CONNECTION ON BATTERIES FOR GENERAL ALARM GENERATOR ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
INFLATABLE RAFT #2 TO BE SERVICED BY APPROVED SERVICING COMPANY.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
LINE THROWING GUN TO BE TESTED AND LOGGED.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
MAKE OPERATIONAL THE VISUAL INDICATOR LAMP FOR, HOT ENGINE, HIGH JACKET WATER TEMPERATURE #3.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
REPAIR OR REPLACE THE WASTED DISCHARGE BELL REDUCER AND PUMP HOUSING, STANDBY FIRE PUMP. UPON COMPLETION OF REPAIRS OPEN THE DISCHARGE SIDE OF THE PRIMARY FIRE PUMP FOR INSPECTION.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
TRANFER PUMP "OUT OF SERVICE" DUE TO CONDITION OF PORTABLE POWER CORD.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Unknown
Issued 23 March 1986 Resolved
PROVIDE ADDITIONAL SUPPORT FOR THE FIRE MAIN IN THE VACINITY OF THE AIR COMPRESSORS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Fire Fighting
Issued 23 March 1986 Resolved
REPLACE SIX 1 1/2 50' FIREHOSES WITH 1 1/2 75' LENGTH TO COMPLY WITH TOTAL HOSE LENGTH AS PER THE COI.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE TREATMENT ROOM: 15 TRAINGULAR BANDAGES, 2-4IN COMPRESSES.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Lifesaving
Issued 23 March 1986 Resolved
MAKE OPERATIONAL THE CLUTCH BRAKE ASSEMBLY FOR THE #12 LIFEBOAT.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Construction/Loadline
Issued 23 March 1986 Resolved
ADJUST/REPAIR THE WATER TIGHT DOOR TO THE PAINT LOCKER.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Construction/Loadline
Issued 23 March 1986 Resolved
REPAIR OR REPLACE THE WATER TIGHT HATCHES TO BOTH "P" TANK STORAGE ROOMS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVIDE COAST GUARD APPROVAL DATA FOR THE MARINE SANITATION DEVICE ON BOARD THE VESSEL.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Lifesaving
Issued 23 March 1986 Resolved
CONDUCT WEIGHT TEST #3 LIFEBOATS. ALSO TEST LIMIT SWITCHES, BRAKE AND DISENGAGING GEAR.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
CONDUCT OVERSPEED TEST TO #1 & 2 ENGINE GENERATOR SETS, PROVE SATISFACTORY TEST OF THE LOW LUBE OIL AND HIGH WATER JACKET TEMPERATURE ALARMS OVERSPEEDSHALL NOT BE SET ABOVE 115 OF RATED SPEED.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
OPEN ALL AIR RECEIVERS FOR INTERNAL INSPECT OR HYDROSTATIC TEST EXCLUDING CEMENT TANKS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Navigation
Issued 23 March 1986 Resolved
MAKE OPERATIONAL THE CALL BELL & LIGHT SYSTEM FOR THE INTERNAL COMMUNICATION IN PORT BALLAST PUMP ROOM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Navigation
Issued 23 March 1986 Resolved
REPLACE BULBS IN NAVIGATION LIGHTS WITH APPROVED FOR MARINE USE BULBS THAT PROVIDE SUFFICIENT ILLUMINATION.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
ADJUST VALVE OPEN/CLOSE INDICATOR FOR THE OVERBOARD DISCHARGE IN STARBOARD PUMPROOM TO INDICATE WHEN VALVE IS OPEN OR CLOSED.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Deck/Cargo
Issued 23 March 1986 Resolved
REPLACE DRILL WATER LINE IN MUD PUMP ROOM THAT IS LEAKING DUE TO WASTAGE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
FREE ALL MANUAL VALVES IN THE PORT/STBD PUMP ROOMS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Accommodation/Occupational Safety
Issued 23 March 1986 Resolved
PROVE SATISFACTORY OPERATION OF ALL RELIEF VALVES ON THE AIR RECEIVERS EXCLUDING THE BAYRITE TANKS. THIS INCLUDES THE TENSIONER SYSTEM.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
REMOVE ALL DEAD END WIRES ABOVE DRILLERS CONSOLE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
REPLACE PLASTIC TIE WRAPS WITH METAL BANDS FOR ALL WIRING ABOVE DRILLER'S CONSOLE AND SUPPORT WIRES WITH CABLE TRAYS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
REMOVE SCHLUM BERGER MONITOR ABOVE DRILLER'S CONSOLE OR PROVIDE EVIDENCE THAT IT HAS AN APPROVAL NAME PLATE FOR A CLASS I, DIVISION II DESIGNATION.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
MAKE OPERATIVE GENERAL ALARM BELLS IN VICINITY OF THE MOON POOL.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
MAKE OPERATIVE EMERGENCY LIGHT IN STARBOARD UPPER COLUMN.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Electrical
Issued 23 March 1986 Resolved
PROVIDE "CHICO" FOR ELECTICAL FITTINGS IN VICINITY OF DRILLER'S CONSOLE.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Engineering
Issued 23 March 1986 Resolved
REPLACE PLASTIC SIGHT GLASS WITH HEAT RESISTENT MATERIAL ON FUEL LOCATION ADJACENT TO LOGGING UNIT.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Fire Fighting
Issued 23 March 1986 Resolved
PROVIDE ADEQUATE PRESSURE TO THE DRY CHEMICAL SYSTEM FOR THE HELO DECK.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Lifesaving
Issued 23 March 1986 Resolved
RENEW FALLS FOR #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Lifesaving
Issued 23 March 1986 Resolved
REPLACE BROKEN WINDOW IN #3 LIFEBOAT.
Condition: Unknown
Due 23 March 1986
Resolved 23 March 1986
Deck/Cargo
Issued 18 March 1985 Resolved
PROVIDE PERSONNEL PROTECTION TO THE AIR TUGGERS IN THE MOON POOL AREA. 46 CFR NVC 4-78,(3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Lifesaving
Issued 18 March 1985 Resolved
MANNING IS TO BE REDUCED FROM 56 TO 55 PERSONS UNTIL THE #1 LIFERAFT IS RETURNED AFTER SERVICING. 46 CFR, APP. - A, NVC 4-78, (3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
REPAIR THE LOW LUBE OIL PRESSURE ALARMS ON NUMBER 1 & 2 DIESEL GENERATORS. 46 CFR, APPENDIX A.
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
REPAIR THE GENERAL ALARM BELL IN THE PORT SIDE OF THE PUMP ROOM. 46 CFR NVC 4-78, 93)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Construction/Loadline
Issued 18 March 1985 Resolved
MAKE SECURE THE LADDER TO THE STARBOARD PUMP ROOM. 46 CFR NVC 4-78,(3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
PROVIDE A GENERAL ALARM BELL IN THE KOOMEY ROOM. 46 CFR, NVC 4-78, (3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
PROVIDE A GENERAL ALARM BELL IN THE EVAPORATOR SPACE. 46 CFR, NVC 4-78, (3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
PROVIDE ADEQUATE LIGHTING TO THE BATTERY ROOM IN THE CORNER OF THE ENGINE ROOM. 46 CFR NVC 4-78, (3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
MOUNT THE SWITCH FOR THE MUD AGITATOR MOTOR OVER THE MUD PIT AREA. 46 CFR NVC 4-78, (3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
PROVIDE THE PROPER MARKING FOR THE GENERAL ALARM BELL ON THE DRILL FLOOR. 46 CFR, NVC 4-78,(3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Electrical
Issued 18 March 1985 Resolved
PROVIDE A GENERAL ALARM WARNING LIGHT IN THE MOTOR ROOM. 46 CFR, NVC 4-78,(3)(D).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Unknown
Issued 18 March 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU DIAMOND M CENTURY DN552669.
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Lifesaving
Issued 18 March 1985 Resolved
PROVIDE APPROVED DAVIT LAUNCHED LIFESAVING EQUIPMENT AT THE RAFT STATIONS 3 & 4 WHERE THE EQUIPMENT HAS BEEN REPLACED. 46 CFR APPENDIX A, NVC 4-78, 3D(1)(B).
Condition: Unknown
Due 18 March 1985
Resolved 18 March 1985
Construction/Loadline
Issued 20 October 1984 Resolved
COMPLETE DRYDOCKING REQUIREMENTS BY SPECIAL EXAM OF UNDERWATER PORTION OF PORT AND STARBOARD PONTOONS.
Condition: Unknown
Due 20 October 1984
Resolved 20 October 1984
Unknown
Issued 1 August 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DIAMOND "M" CENTURY 552669AND ARE TO BE COMPLIED BY 01NOV84.
Condition: Unknown
Due 1 August 1984
Resolved 1 August 1984
Construction/Loadline
Issued 1 August 1984 Resolved
MAKE PERMANENT REPAIRS TO DAMAGED AREAS OF THE STARBOARD PONTOON BOW BALLAST TANK AT NEXT RIG MOVE OR (90) DAYS 01NOV84 WHICH EVER COMES FIRST.
Condition: Unknown
Due 1 August 1984
Resolved 1 August 1984
Deck/Cargo
Issued 22 March 1984 Resolved
TEST RELIEF VALVES FOR ALL AIR RECEIVERS AND MUD PUMPS. TO BE COMPLETED NOT LATER THAN NEXT MOVE OF VESSEL
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Deck/Cargo
Issued 22 March 1984 Resolved
TEST RELIEF VALVES ON ALL P TANKS AND CONDUCT INTERNAL EXAM OF SAME. TO BECOMPLETED NOT LATER THAN NEXT MOVE OF VESSEL
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Unknown
Issued 22 March 1984 Resolved
CONDUCT INTERNAL EXAM ON TINTIONER BOTTLES 10 EACH, TO BE COMPLETED NOT LATER THAN NEXT MOVE OF VESSEL
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Construction/Loadline
Issued 22 March 1984 Resolved
REPAIR WASTED HAND RAILS, NUMEROUS AREAS ON PERIMETER OF VESSEL
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.