Documentation record
Registered dimensions (L × B × D)66.1 ft × 26.0 ft × 10.0 ft
Registered tonnagegross 178 / net 121
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRIMPLER'S SHIPBUILDING COMPAN · ORANGE, TX, UNITED STATES · built 1982
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST LOUIS, MO
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it178 - Regulatory (Subpart C or D), Gross Ton
121 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 47
28 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8357337
6 December 2024
DAPI Audit · Administrative Inspection · Examination of Repairs · Deficiency Check · Damage Survey · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8044127
30 April 2024
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7905260
2 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7679202
14 July 2022
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7507097
10 May 2022
COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7448897
10 December 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7110008
10 December 2019
MTSA Verification · COI Inspection · Initial Certification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6871439
7 July 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6201048
3 May 2016
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 5868603
28 April 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5114748
20 April 2015
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 5123998
21 March 2015
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5093256
8 March 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5091020
11 February 2015
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5819621
2 December 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5038336
19 April 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4839746
25 January 2014
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4793847
9 April 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4565634
9 August 2012
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 4406498
12 March 2012
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4262020
12 March 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4262899
26 January 2012
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4232528
12 February 2011
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3945169
10 September 2010
MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3846404
30 August 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3852058
6 December 2009
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3645816
5 December 2009
Administration
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3645771
2 May 2009
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3472358
3 April 2009
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3445733
11 April 2008
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3182187
12 December 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2839785
30 June 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2696545
19 June 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2688002
19 June 2006
Deficiency Check · Uninspected Other · Damage Survey · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2748604
27 May 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2678918
19 July 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2464782
13 June 2005
MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2389048
25 January 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2280540
17 November 2004
Annual Inspection · MTSA Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2243662
27 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2229758
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1990413
11 December 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 138428
10 December 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 138156
9 January 1998
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 101336
21 October 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 16851
4 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309950
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2025
Resolved
The fire detection system must be arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. A repeater/sub panel is located at the operating station, the control panel is located just forward of the engine room. Deficiency to be correct by the vessel's 1st annual inspection (due by 6/13/2026).
Action required: 705 - Other - as specified
Resolved 19 May 2026
Resolution: MI verified proper installation of control panel for fire detection system at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 March 2025
Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of 46 CFR 199.190 of this chapter...each battery clearly marked with an expiration date and used in an item of survival equipment must be replaced during the annual inspection if the expiration date has passed (46 CFR 199.190(f)(4)). Port side water light battery was past its expiration date by more than a year.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2025
Resolution: New waterlights with new batteries incorporated on board vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2025
Resolved
Safety orientation (required by 46 CFR 140.410) and navigation safety training (required by 46 CFR 140.645) required to be recorded in the vessel's towing vessel record (TVR) or official log book. The vessel's master was not able to provide records of these items for the vessel's crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2025
Resolution: Document showing completion of crew orientation and navigation safety training added to vessel TVR.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2025
Resolved
The fire detection system must be arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. The sub panel located at the operating station did not function during testing of 2 temperature probes in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2025
Resolution: System serviced and repaired by third party, tech report provided showing system fully functional.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 30 April 2024
Resolved
Vessels low hydraulic tank alarm on the bridge when engaged made all the visual displays appear in lieu of just the low hydraulic tank alarm. All other alarms only engaged their assigned light. Repair visual low hydraulic tank alarm on the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2024
Resolved 30 May 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 April 2024
Resolved
Emergency light failed to operate. Ensure all emergency lights are fully operational. Repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 13 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2023
Resolved
Vessel must have serviceable life jackets labeled with the vessel name in block letters, a light securely attached to the front shoulder area of the life jacket with a whistle firmly secured by a cord. Life jackets had faded retro tape, and whistles attached via plastic zip ties to the strap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 25 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2023
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity. Location in Captains bunk was labeled "2" when only one was in the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 25 May 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 May 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either automatic battery operated or Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 25 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2023
Resolved
Each ring buoy should be approved under approval code 160.050 or 160.150. Ring buoy must be orange or white in color for a rivers route. Ring buoys had large blacked out sections limiting the amount of visabiity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 25 May 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 May 2022
Resolved
A vessel must be operated IAW w/applicable laws and regulations. Vessel's fire detection system must meet those standards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 23 May 2022
Resolution: Fire Detection System operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 May 2022
Resolved
The vessel's sea chest a has a leak. Repair leak and any other effected components. Provide repair report to MSD Quad Cities.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 23 May 2022
Resolution: Sea chest repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 May 2022
Resolved
Vessel is required to have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Vessel's pressure is not marked or labeled IAW w/regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 23 May 2022
Resolution: Pressure vessel data plate installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 May 2022
Resolved
Vessel's hatches have unserviceable gaskets. Replace gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 6 June 2022
Resolution: New gaskets have been installed
Engineering › Steering Gear System › Actuator
Issued 26 January 2012
Resolved
The vessel's port hydraulic actuator arm where it is attached to the port rudder stock is damaged. The vessel is to make permanent repairs to the port hydraulic actuator arm where it is attached to the port rudder stock.
Condition: Improper/Lack of Maintenance
Due 26 January 2012
Resolved 27 January 2012
Resolution: Verified permanent repairs have been made. Actuator arm attachment has been built up to be better than original configuration of having all thread welded to the rudder stock.
Documentation
Issued 4 June 1986
Resolved
VESSEL DID NOT HAVE A CERTIFICATE OF DOCUMENTATION ON BOARD AS REQUIRED BY 46CFR67.45-5.
Condition: Unknown
Due 4 June 1986
Resolved 4 June 1986