Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1754 - Simplified, Gross Ton
1403 - Simplified, Net Ton
Maury page id
psix-22222
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Vessels port Rake bilge knuckle damaged, required crop and renew at 2011 ISE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 July 2011
Resolution: Conducted SAT air test and visual inspection of port rake bilge knuckle.
Construction/Loadline › Hull › Stiffener
Issued 13 March 2009Resolved
Vessel permitted 1 voyage to load cargo at Exxon Mobile MM 278 and Transit to the Korral Dock MM 297.8 for off Load of cargo. Upon Offload effect repairs in way of the bow rake void starboard side 1st two transverse frames to the satisfaction of an attending marine inspector. Barge must remain in OCMI Chicago zone until repairs are made.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: See Misle Activity 3426282 and scanned doc for details.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 June 2005Resolved
Paint loadline and draft marks in contrasting color.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 20 July 2005
Resolution: owners rep. e-mailed photos of painted loadline and draft marks, cleared deficiency.
Electrical › Lighting (service) › Outlet Box
Issued 22 June 2005Resolved
Replace missing cover on stern electrical fitting.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 23 June 2005
Resolution: Cover Replaced.
Deck/Cargo › Cargo Heating › General
Issued 22 June 2005Resolved
Repair refractory sight gauge to allow open position on thermal fluid heater.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 23 June 2005
Resolution: Refractory sight gauge repaired.
Construction/Loadline › Hull
Issued 13 May 2002Resolved
Prior to loading Cargo have barge gas free for attending Marine Inspector to survey damage to Bow Rake and #1 Voids. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2002
Resolved 31 May 2002