Records from 2001 to 2025. Most recent: inspection, 8 November 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,754 / net 1,403
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2001
Hull materialSteel
PropulsionNone
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1754 - Simplified, Gross Ton
1403 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
8 November 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8269661
23 July 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8193585
11 December 2023
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7836691
24 January 2022
Examination of Repairs · Internal Structural Exam · COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7384721
1 October 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7324705
13 November 2019
MTSA Verification · MARPOL Annex VI Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6855032
27 January 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6621284
14 January 2019
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6609848
28 December 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6329803
22 June 2016
Examination of Repairs · Cargo Tank Internal · Administrative Inspection · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5915214
20 August 2015
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5222002
11 December 2014
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5037768
18 August 2014
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4958345
17 September 2013
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4712131
19 September 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4445015
13 July 2011
Cargo Tank Internal · MTSA Verification · Internal Structural Exam · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4072927
6 July 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3787746
11 May 2010
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3736371
8 May 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3735069
19 March 2009
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3436282
13 March 2009
Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3435024
10 February 2009
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3415728
19 November 2008
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3366350
18 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3270493
28 June 2007
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2976782
15 November 2006
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2821228
21 July 2006
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2720178
20 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2741664
25 May 2006
Internal Structural Exam · COI Inspection · Administrative Inspection · MTSA Verification · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2658495
29 December 2005
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2560829
20 July 2005
Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2438907
22 June 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2398871
14 April 2005
Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2333584
5 April 2004
Periodic Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2033990
24 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1954050
19 July 2003
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1991385
26 March 2003
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1763230
13 May 2002
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1616239
15 March 2002
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1495632
30 March 2001
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1459689
Construction/Loadline › Hull › Double Hull
Issued 11 May 2010
Resolved
Vessels port Rake bilge knuckle damaged, required crop and renew at 2011 ISE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 July 2011
Resolution: Conducted SAT air test and visual inspection of port rake bilge knuckle.
Construction/Loadline › Hull › Stiffener
Issued 13 March 2009
Resolved
Vessel permitted 1 voyage to load cargo at Exxon Mobile MM 278 and Transit to the Korral Dock MM 297.8 for off Load of cargo. Upon Offload effect repairs in way of the bow rake void starboard side 1st two transverse frames to the satisfaction of an attending marine inspector. Barge must remain in [name withheld] zone until repairs are made.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: See Misle Activity 3426282 and scanned doc for details.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 June 2005
Resolved
Paint loadline and draft marks in contrasting color.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 20 July 2005
Resolution: owners rep. e-mailed photos of painted loadline and draft marks, cleared deficiency.
Electrical › Lighting (service) › Outlet Box
Issued 22 June 2005
Resolved
Replace missing cover on stern electrical fitting.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 23 June 2005
Resolution: Cover Replaced.
Deck/Cargo › Cargo Heating › General
Issued 22 June 2005
Resolved
Repair refractory sight gauge to allow open position on thermal fluid heater.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 23 June 2005
Resolution: Refractory sight gauge repaired.
Construction/Loadline › Hull
Issued 13 May 2002
Resolved
Prior to loading Cargo have barge gas free for attending Marine Inspector to survey damage to Bow Rake and #1 Voids. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2002
Resolved 31 May 2002