MAURY USCG vessel records
← All vessels

MAUNA LOA

Built
1984
Last inspected
5 August 2019
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 5 August 2019
…with no type recorded124
Operational controls None recorded without a removal date
Years with a record 34 calendar years (1984–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

240912
Flag
UNITED STATES
Tonnage
3457 - Convention (Subpart B), Gross Ton 3520 - Dead Weight, Ton 1037 - Convention (Subpart B), Net Ton
Maury page id
psix-240912
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

Inspection history · 202

5 August 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6773753
9 April 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6658893
15 February 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6078674
11 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6064165
25 May 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886610
18 March 2015 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5085557
12 March 2015 Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5036369
17 September 2014 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4986638
9 April 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4831390
5 November 2013 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4748114
30 November 2012 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4493858
12 November 2012 Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4404788
28 March 2012 Cargo Tank Internal
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4274164
13 February 2012 COI Inspection · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4243856
16 December 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3912089
10 March 2010 Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3691948
17 February 2010 Periodic Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3681392
8 July 2009 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3528552
1 April 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3444583
28 January 2009 Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3402864
6 August 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3364871
17 April 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3186297
11 October 2007 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3077919
17 September 2007 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2990351
25 April 2007 Drydock Extension · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2912107
21 February 2007 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2860604
8 February 2007 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2874683
29 November 2006 MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2826497
22 February 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2588634
30 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2322883
9 March 2005 MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2306997
24 February 2005 Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2347671
26 May 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2066958
18 May 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2071731
17 May 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2071693
17 May 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2078130
28 April 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2051335
11 February 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2005509
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971709
4 December 2003 Periodic Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1951131
19 March 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1760918
19 February 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1741090
3 April 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1494482
26 March 2002 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1599231
27 February 2002 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1489496
26 February 2002 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1489608
9 February 2002 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1489945
8 February 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1491480
26 November 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1419006
1 November 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393549
1 March 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 815986
16 February 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384369
2 January 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387
9 November 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1466089
5 January 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434817
4 November 1998 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1472338
19 November 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381058
10 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1110096
24 April 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1101819
17 March 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371687
13 November 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354057
15 January 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 872323
10 January 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1188910
4 December 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383103
11 November 1995 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377550
8 November 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 157846
8 November 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1079332
8 March 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 196213
8 March 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 752709
27 February 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380156
19 February 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358656
18 January 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 865016
21 December 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1158891
14 November 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374163
26 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661231
18 July 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 136621
18 July 1994 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367112
7 February 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 60195
22 November 1993 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377091
27 October 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 29689
11 August 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1157441
20 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661227
1 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 45744
12 March 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 67334
23 November 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139999
28 April 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661228
22 April 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 63536
26 March 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948187
17 March 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015093
4 March 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1266906
18 February 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 957966
31 December 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1379672
18 December 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 959770
2 January 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 924271
5 December 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902411
6 December 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1228915
15 November 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902044
21 March 1989 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1207836
8 December 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1041941
7 December 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1351207
26 October 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 526537
6 January 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1020085
21 December 1987 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1009446
25 November 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1027491
8 October 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 473802
25 September 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 446501
24 September 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 449381
17 September 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 535243
10 July 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1332648
30 April 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 501003
3 February 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316306
21 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1317220
9 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 491446
8 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 456051
8 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1005539
8 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1317691
22 December 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1027919
18 December 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 463628
18 December 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 475593
6 December 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 476685
6 December 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1025756
25 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 444892
25 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 485461
23 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 460092
22 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 459542
30 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 505562
29 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 475184
23 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 448336
22 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 478245
16 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 468404
16 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 510590
9 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 506480
2 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 465369
1 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 527871
19 September 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 511973
17 September 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 498389
16 September 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006043
11 September 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 503257
18 August 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 489841
8 August 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 513283
7 August 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 481460
5 August 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 514777
24 July 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 465053
10 July 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 498903
26 June 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 505405
24 June 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 523799
20 June 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 455767
19 June 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 511634
22 May 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 490464
21 May 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 519928
23 April 1986 Initial Construction-Excluding Oversight
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1306329
4 April 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 509599
3 April 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 496860
13 March 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 505378
9 March 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 519021
6 March 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 512694
13 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 442658
13 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 470318
13 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 539611
6 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 492449
6 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 534494
25 January 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 440389
25 January 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 508151
18 January 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 460712
18 January 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 518959
14 January 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 445772
31 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989156
27 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 495725
18 December 1985 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 996675
6 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 456827
6 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 498839
28 November 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 480195
19 November 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 535462
15 November 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 445336
14 November 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 510565
24 October 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 460837
24 October 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 531592
3 October 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 497811
3 October 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 518090
26 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 500792
25 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 484319
12 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 527767
11 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 470018
29 August 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 481226
22 August 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 535345
21 August 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 510083
13 August 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 442355
11 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 457430
3 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 493183
2 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 987774
22 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 473158
20 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 539313
11 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288993
6 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 507788
29 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 493159
22 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 504221
2 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1288409
1 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 521973
20 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984340
5 February 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 976634
23 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1283125
11 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982418

Deficiency record · 157

Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 15 February 2017 Resolved
MARPOL Annex I/12 - Sludge tanks shall have no discharge connection to the bilge system, bilge holding tanks, or OWS. The vessel is equipped with (01) sludge tank and (01) bilge tank both with a discharge connection to the OWS. Evaluate the current configuration and submit drawings to the USCG Marine Safety Center for review and approval to MARPOL. The vessel is restricted to a domestic route only
Condition: Placed in Improper Service
Due 30 November 2017
Resolved 5 August 2019
Resolution: Vessel scrapped and no longer in service as indicated per MISLE#6658893. Def considered cleared.
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 15 February 2017 Resolved
46 CFR 95-10 - The flexible hoses (3) on the approved fire extinguishing system (HALON) were replaced with underrated hoses. Replace all hoses with the manufactures approved equipment within 30 days.
Condition: Placed in Improper Service
Due 15 March 2017
Resolved 17 May 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 15 February 2017 Resolved
46 CFR 95-10 – Provided the CO2 system approval manual to verify the authorization of the mixed matched equipment found on board within 30 days.
Condition: Placed in Improper Service
Due 30 November 2017
Resolved 5 August 2019
Resolution: Vessel scrapped and no longer in service as indicated per MISLE#6658893. Def considered cleared.
Stability › Intact Stability (when using lifting gear) › General
Issued 15 February 2017 Resolved
46 CFR 97.15-7 – Prove that the loading/stability program used is an approved method for determining the vessel’s stability or ensure calculations are made using the approved stability book after loading and prior to departure.
Condition: Placed in Improper Service
Due 15 February 2017
Resolved 15 February 2017
Construction/Loadline › Structures › Ventilators
Issued 15 February 2017 Resolved
46 CFR 92.15-10 – Remove mousing and make repairs to the ventilation closure holdbacks to ensure functionality of the closing devices within 30 days.
Condition: Improper/Lack of Maintenance
Due 15 March 2017
Resolved 17 May 2017
Electrical › Electric Generation Source (service) › Ground Detection
Issued 15 February 2017 Resolved
46 CFR 111.05-21 – Repair in operative ground detector on the lighting panel P10 within 30 days.
Condition: Improper/Lack of Maintenance
Due 15 March 2017
Resolved 17 May 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 15 February 2017 Resolved
46 CFR 111.81-1 – Provide a permanently mounted outlet box for the welder receptacle located in the forward mechanical room or removed the portable cable and receptacle within 30 days.
Due 15 March 2017
Resolved 17 May 2017
Deck/Cargo › Cargo Condition › Other Cargo Type
Issued 15 February 2017 Resolved
Prove the proper operation of the installed bulk molasses cargo system to include but not limited to the piping, valves, pumps, heating coils, and reliefs in accordance with 46 CFR Subchapter F or request that the authorization for the carriage of molasses in bulk be removed from the vessel’s COI and provide a decommissioning time frame of the system.
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 5 August 2019
Resolution: Vessel scrapped and no longer in service as indicated per MISLE#6658893. Def considered cleared.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2016 Resolved
Prove proper operation of emergency lighting, and properly label emergency lights.
Condition: Improper/Lack of Maintenance
Due 25 June 2016
Resolved 5 August 2019
Resolution: Vessel scrapped and no longer in service as indicated per MISLE#6658893. Def considered cleared.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 25 May 2016 Resolved
Prove proper operation of oily water seperator IAW International Oil Pollution Prevention Certicate.
Condition: Improper/Lack of Maintenance
Due 25 June 2016
Resolved 5 August 2019
Resolution: Vessel scrapped and no longer in service as indicated per MISLE#6658893. Def considered cleared.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 March 2015 Resolved
Ensure exhaust piping is properly insulated to protect personnel.
Action required: 705 - Other - as specified
Due 2 April 2015
Resolved 25 May 2016
Resolution: Exhaust piping properly insulated.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 18 March 2015 Resolved
Remove fuel from containment under fuel strainers located under deckplates on the STBD side of engine room.
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 26 May 2016
Resolution: Verified fuel was removed from containment.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 18 March 2015 Resolved
Repair wasted davit post/pedestal used for molases cargo hoses or remove from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2015
Resolved 25 May 2016
Resolution: Removed wasted davit post.
Engineering › Diesel Engine (auxiliary) › Bearing
Issued 18 March 2015 Resolved
Submit repair proposal to repair/replace leaking rear main seal on crane generator.
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 25 May 2016
Resolution: Verified no leak on rear main seal crane generator.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 18 March 2015 Resolved
Replace unapproved Ansul pressure switches which are installed in the Kidde Halon system for the lower machinery space. Replacement pressure switches must be listed on the USCG approved parts list in the approved Kidde Halon System manual.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2015
Resolved 18 May 2016
Resolution: System serviced and unapproved ANSUL pressure switches replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 March 2015 Resolved
Provide date at which the pneumatic detection/actuation of the fixed gas fire extinguishing systems can be tested/maintained IAW their USCG approved design, installation, operation, & maintenance manuals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2015
Resolved 25 May 2016
Resolution: Witnessed servicing report.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 March 2015 Resolved
Vessel failed to complete an Internal Structure Exam by the date required on the Certificate of Inspection.
Action required: 705 - Other - as specified
Due 12 March 2015
Resolved 12 March 2015
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 March 2015 Resolved
Submit permanent repair proposal for wasted sea chest vent piping located in void #7, centerline at fwd bulkhead to OCMI for approval.
Action required: 705 - Other - as specified
Due 19 March 2015
Resolved 25 May 2016
Resolution: Repair completed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 March 2015 Resolved
Permanently repair sea chest vent pipe IAW approved repair proposal.
Action required: 705 - Other - as specified
Due 12 April 2015
Resolved 25 May 2016
Resolution: Sea chest vent pipe permanently repaired.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 April 2014 Resolved
Demonstrate proper operation of oily water separator.
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 17 September 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 April 2014 Resolved
Hydro test or renew hoses on upper deck crane and lower deck fire control room.
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 17 September 2014
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 March 2010 Resolved
In # 1 void, forward rake end, grind an reweld the following fractures: (a) connection between frame # 5 port and bottom plate, (b) connection between frame # 4 port and main deck, (c) connection between frame # 2 port and main deck, (d) connection between frame # 5 starboard and main deck. If fracture extends into main deck plating provide repair proposal.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 21 April 2010
Construction/Loadline › Hull › Stiffener
Issued 10 March 2010 Resolved
in # 3 void grind and reweld fractures in way of boarding ladder recesses, starboard side.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 21 April 2010
Construction/Loadline › Hull › Girder
Issued 10 March 2010 Resolved
In # 3 void grind and clean base of gusset supporting main port side under deck girder at forward bulkhead near ladder. Provide report on condition to Coast Guard.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 21 April 2010
Construction/Loadline › Hull › Bottom Plating
Issued 10 March 2010 Resolved
In # 2 void provide gauging of bottom plate forward of aft bulkhead, outboard of starboard deep longitudinal.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 24 March 2010
Construction/Loadline › Hull › Bottom Plating
Issued 10 March 2010 Resolved
In # 2 void provide gauging of bottom plate in way of port and starboard void vents at limber hole.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 24 March 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 March 2010 Resolved
Provide installation dates for all non-metallic expansion joints in engine space. Label each accordingly.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 21 April 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 10 March 2010 Resolved
Remove all oil and water from engine room bilges and make available for inspection.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 21 April 2010
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 April 2009 Resolved
Prove proper operation of OWS system. Make proper repairs to OWS ovbd discharged line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 1 April 2009 Resolved
Prove proper operation of port machinery space bilge alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Construction/Loadline › Structures › Manhole
Issued 1 April 2009 Resolved
Make engine space port escape scuttle water tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 April 2009 Resolved
Install metal fasteners throughout engine space for improperly hung wire runs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 13 May 2009
Engineering › Fuel Oil Service System › Valve
Issued 1 April 2009 Resolved
Properly label fuel shutoff valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 April 2009 Resolved
Repair latch for panel door PII located in engine space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 April 2009 Resolved
Properly lable fixed fire system audio alarm in engine space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Fire Fighting › Ventilation Systems › Stairway Enclosure Ventilation
Issued 1 April 2009 Resolved
Prove proper operation of stbd engine room vent cover.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 April 2009 Resolved
Provide hydro testing report for all fixed firre system bottles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Construction/Loadline › Structures › Door
Issued 1 April 2009 Resolved
Properly repair gasket for stbd fwd deck store WTD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Construction/Loadline › Structures › Door
Issued 1 April 2009 Resolved
Provide dogging wrenches for: stbd WTD fwd, (2) aft eng room WTD, (1) CO2 WTD, (2) WTD between halon and eng room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 6 May 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 July 2007 Resolved
Prove proper operation of Halon system thruster engine shut down circuit. The switch operated normally during the blow down test with Co2 but the thruster engine was inoperable due to maintenance. recommend manually lifting shutdown switch to verify engine shutdown. Complete prior to operating thruster engine while underway, to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 11 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 25 April 2007 Resolved
See narrative from Activity #2912107 for composite list of required drydock worklist repairs noted during ISE of 25APR2007 attended by USCG and ABS. See also (10) CG-835s given to vessel during 21FEB2007 inspection for certification.
Due 20 July 2007
Resolved 17 September 2007
Resolution: Completed worklist items.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 21 February 2007 Resolved
Properly service fire extinguisher in fwd store room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 21 February 2007
Resolution: Extinguisher changed out.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 21 February 2007 Resolved
Properly repair ground detector lights in fwd store room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 21 February 2007
Resolution: Repair completed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 February 2007 Resolved
Properly secure capstan control boxes on Focsle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 7 March 2007
Engineering › Fuel Oil Service System › Ventilation
Issued 21 February 2007 Resolved
Properly clean port fuel tank vent screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 7 March 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 21 February 2007 Resolved
Prove proper operation of emergency lights IVO Exit to Engine Room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 18 April 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 21 February 2007 Resolved
Properly repair lights in crane house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 7 March 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 February 2007 Resolved
Prove proper operation of crane house doors.
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 7 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 21 February 2007 Resolved
Properly secure deck light IVO crane stairwell.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 7 March 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 February 2007 Resolved
C/R machinery guards for port and stbd capstan drive shafts at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Machinery guard was replaced.
Engineering › Compressed Air System (control) › Piping
Issued 21 February 2007 Resolved
C/R guards for compressed air lines on main deck at next drydock.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Installed new guards.
Construction/Loadline › Structures › Manhole
Issued 21 February 2007 Resolved
C/R escape hatches for main engine space at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Renewed both escape hatches. test sat
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 February 2007 Resolved
C/R hose reel for crane diesel fuel tank at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Renewed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 February 2007 Resolved
C/R holes in house for crane equipment at next drydock.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 11 October 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 21 February 2007 Resolved
Properly install fuel vent on crane diesel tank at next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 11 October 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 8 February 2007 Resolved
Provide service report and prove operation of crane engineering space CO2 system. Until repairs are made vsl may operate with the following restrictions in place: (1) live fire watch during all crane operations, (2) semi-portable fire extinguisher to be placed outside crane space, and (3) all crane machinery, electrical and pressure vsls are to be secured while underway.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2007
Resolved 14 February 2007
Resolution: Oahu Fire report of testing received via fax.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 February 2006 Resolved
Port side navigation light not operating. Correct prior to transit at night.
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 23 February 2006
Resolution: Received phone call from [name withheld] stating that the navigation light was replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 February 2005 Resolved
C+R AFT BULKHEAD FR 108 IN VOID #7, TOP CORNER AT SIDE SHELL APPOX 18" x 18"
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Inserted area test sat.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 February 2005 Resolved
C + R SECOND SIDE LONG FROM TOP STARBOARD SIDE BETWEEN FR 27 AND FR 30
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Renewed affected longs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 February 2005 Resolved
C + R THIRD SIDE LONG FROM TOP STARBOARD SIDE IN VOID #3 BETWEEN FR 23 AND FR 33
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 17 September 2007
Resolution: Renewed affected longs.
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 April 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 14 May 2004
Resolved 26 May 2004
Resolution: Vsl rmv''d kit.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 19 February 2003 Resolved
Make legible all operating and safety instructions for the CO2 system in the crane machinery room. LEGACY COMPONENT DESC: Operating Controls
Due 19 March 2003
Resolved 19 March 2003
Construction/Loadline › Markings
Issued 19 February 2003 Resolved
Paint deck reference lines for load lines. LEGACY COMPONENT DESC: Load Line Mark
Due 19 March 2003
Resolved 19 March 2003
Construction/Loadline › Hull
Issued 3 April 2002 Resolved
#2 Void: Found weld fractures: - #1 stbd deck longitudinal IWO #12/13 bottom transverse frames. Repair to original condition. - #1 port deck longitudinal IWO #12/13 bottom transverse frames. Repair to original condition. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Due 30 April 2002
Resolved 16 April 2002
Construction/Loadline › Structures
Issued 3 April 2002 Resolved
#4 port void; descale frame #57 IWO #1, 2 & 3 bottom longitudinals. LEGACY COMPONENT DESC: longitudinal
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 16 April 2002
Construction/Loadline › Hull
Issued 3 April 2002 Resolved
#5 P void; port frame #57 IWO #2 side longitudinal (near hatch), distorted. Affect repairs to side longitudinal and tripped bracket. Crop/renew 10' section of sideshell longitudinal #1 (upper) IWO frames #63-66. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 30 April 2002
Resolved 16 April 2002
Construction/Loadline › Structures
Issued 3 April 2002 Resolved
#7 void; Found 6" weld fracture at #1 port pillar IWO bottom frame #102. Affect repairs. LEGACY COMPONENT DESC: pillar
Condition: Damaged By Earlier Event
Due 30 April 2002
Resolved 16 April 2002
Construction/Loadline › Hull
Issued 3 April 2002 Resolved
#6 Ballast tank: Found side shell inset/distorted longs. Frame #84 IWO #3 & 4 side longs, crop renew (4'x4' section of side shell plate). LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 30 April 2002
Resolved 16 April 2002
Construction/Loadline › Structures
Issued 3 April 2002 Resolved
#5 S VOID: Crop/renew 5" section of sideshell longitudinal #3 (upper) IWO frame #72. LEGACY COMPONENT DESC: Side longitudinal
Condition: Unknown
Due 30 April 2002
Resolved 16 April 2002
Deck/Cargo › Mooring/Anchoring
Issued 27 February 2002 Resolved
Replace mooring line (Aft/STBD). LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Improper/Lack of Maintenance
Due 27 March 2002
Resolved 1 May 2002
Construction/Loadline › Markings
Issued 27 February 2002 Resolved
Re-paint draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 27 March 2002
Resolved 1 May 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Foc'sle: Repair dead end electrical wires (port side of space). LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 1 March 2002
Resolved 1 May 2002
Deck/Cargo › Holds/Tanks
Issued 27 February 2002 Resolved
#2 Void cover (STBD): Replace stud. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Due 27 March 2002
Resolved 1 May 2002
Operations/Management
Issued 27 February 2002 Resolved
Ensure barge is dry-docked by 2400, 28FEB02 or obtain approved dry-dock extension letter from OCMI. If dry-dock extension letter is not obtained by 2400, 28FEB02, barge is not to conduct commercial trade. LEGACY COMPONENT DESC: DRY-DOCK DUE DATE
Due 28 February 2002
Resolved 28 February 2002
Resolution: Per 14th USCG District [name withheld] Approval (Ltr dated: 28FEB02).
Construction/Loadline
Issued 16 February 2000 Resolved
Replace missing studs for the number 2 void hatches (3 on the port hatch, 1on the starboard hatch) to the satisfaction of the attending marine inspector in accordance with ICLL 66.
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000
Construction/Loadline
Issued 16 February 2000 Resolved
In the number 2 void, crop and renew the top flange on the 2nd bottom longitudinal (port side) in way of frame 21 to the satisfaction of the attending marine inspector in accordance with NVIC 7-68.
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000
Construction/Loadline
Issued 16 February 2000 Resolved
In the number 2 void, gouge and reweld the 3/4 inch crack in the vertical stiffener (lower weld) starboard side in way of frame 17 to the satisfaction of the attending marine inspector in accordance with NVIC 7- 68.
Condition: Unknown
Due 16 February 2000
Resolved 16 February 2000
Engineering
Issued 4 November 1998 Resolved
Provide containment around crane generator fueling station to the satisfaction of the attending marine inspector prior to 03JAN99.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Electrical
Issued 4 November 1998 Resolved
Enclose junction box on the starboard hoist cooling fan to the satisfactionof the attending marine inspector prior to 03JAN99.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Accommodation/Occupational Safety
Issued 4 November 1998 Resolved
Prove proper operation of the deck dampers in the crane generator room to the satisfaction of the attending marine inspector prior to 03JAN99.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Electrical
Issued 4 November 1998 Resolved
Properly blank front of the switchboard in the crane room to the satisfaction of the attending marine inspector prior to 03JAN99.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Electrical
Issued 4 November 1998 Resolved
Replace light fixture above switchboard in crane generator room to the satisfaction of the attending marine inspector prior to 03JAN99.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Lifesaving
Issued 19 November 1997 Resolved
Repair inboard railing on FWD gantry portal crosswalk.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Unknown
Issued 19 November 1997 Resolved
Install Standard Discharge Connection.
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Lifesaving
Issued 19 November 1997 Resolved
Install safety sign at former securing stations access ladders on both portand stbd side of crane wing railing to read, "Warning ladder presents hazard if containers not present."
Condition: Unknown
Due 19 November 1997
Resolved 19 November 1997
Accommodation/Occupational Safety
Issued 17 March 1997 Resolved
Crop & renew wasted ladder rungs in various salt water ballast tanks and voids.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Construction/Loadline
Issued 17 March 1997 Resolved
Properly install bilge/ballast piping & sounding tube support brackets where missing in the port Fwd salt water tank.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Construction/Loadline
Issued 17 March 1997 Resolved
Properly repair the various leaks of the fixed bilge/ballast piping at the aft bulkhead penetrations in #7 void.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 13 November 1996 Resolved
RENEW THREE FLEX HOSES FROM THE THREE FIXED HALON BOTTLES IN THE ENGINE ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Fire Fighting
Issued 13 November 1996 Resolved
RENEW 2 FLEX HOSES AND RAIL HOSE FROM THE TWO FIXED CO2 BOTTLES IN THE ENGINE ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Electrical
Issued 11 November 1995 Resolved
Blank stuffing tube openings in forecastle aft bulkhead.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Electrical
Issued 11 November 1995 Resolved
Renew light covers in crane generator space in front of aux. control switchboard and above the generator.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Accommodation/Occupational Safety
Issued 11 November 1995 Resolved
Renew rail safety chains for crane emergency access catwalk. Catwalk is toremain secured until corrected.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Accommodation/Occupational Safety
Issued 11 November 1995 Resolved
Properly label machinery space emergency exits.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Construction/Loadline
Issued 11 November 1995 Resolved
Prove proper operation of the Oily Water Seperator. Discharge to the sea is to be blocked until corrected.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Construction/Loadline
Issued 11 November 1995 Resolved
Provide hatch gasket for number one void space.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Engineering
Issued 11 November 1995 Resolved
Prove operation of generator J/W temperature sending units.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Deck/Cargo
Issued 11 November 1995 Resolved
Determine source of moisture in 5 void and submit repair proposal to OCMI Honolulu. Vessel may not carry cargo in number 5 port and starboard molasses tanks until repairs are completed.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Documentation
Issued 11 November 1995 Resolved
Provide service certificate for fire fighting and thruster control equipment.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Accommodation/Occupational Safety
Issued 11 November 1995 Resolved
Renew securing dogs for machinery space vent closure.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Electrical
Issued 11 November 1995 Resolved
Properly close cable openings in load shed control panel.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Accommodation/Occupational Safety
Issued 11 November 1995 Resolved
Provide vent closures throughout the vessels as needed.
Condition: Unknown
Due 11 November 1995
Resolved 11 November 1995
Fire Fighting
Issued 8 November 1995 Resolved
MAINTAIN A MANNED WATCH WITH FOUR 30 LBS CO2 HAND PORTABLE FIRE EXTINGUISHERS WHILE CONDUCTING CRANE OPERATIONS UNTIL SYSTEM IS RECHARGED, BUT NOT LATER THAN 11 NOV 1995, IN THE PRESENCE OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 14 November 1994 Resolved
REPAIR OR REPLACE THE REMOTE THRUSTER STATION ON THE PORT SIDE AND DEMONSTRATE SATISFACTORY OPERATION. OR PROVIDE A CENTRAL CONTROL STATION WHICH CAN GIVE THRUSTER CONTROL BY OBSERVING OPERATION FROM EITHER SIDE OF THE VESSEL.
Condition: Unknown
Due 14 November 1994
Resolved 14 November 1994
Fire Fighting
Issued 14 November 1994 Resolved
HAVE FIXED HALON CYLINDERS HYDROSTATICALLY TESTED AND PROVIDE SERVICE REPORTS TO MSO HONOLULU AFTER COMPLETION.
Condition: Unknown
Due 14 November 1994
Resolved 14 November 1994
Engineering
Issued 14 November 1994 Resolved
RETHREAD CONTAINMENT PLUGS AT ALL CONTAINMENT AREAS.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Lifesaving
Issued 14 November 1994 Resolved
RESTENCIL EMERGENCY FUEL SHUT OFF VALVES.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Lifesaving
Issued 14 November 1994 Resolved
PROPERLY LABEL EXTERIOR SIDES OF EMERGENCY ESCAPE HATCHES_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Deck/Cargo
Issued 18 July 1994 Resolved
PRIOR TO CARRYING FREIGHT FOR HIRE, PROVE PROPER OPERATION OF CARGO CRANE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 19 September 1994
Resolved 4 August 1994
Construction/Loadline
Issued 18 July 1994 Resolved
EXAMINE AND LOG THE CONDITION OF THE TEMPORARY REPAIRS MADE TO THE DAMAGED BOW EACH MONTH. NOTIFY THE INSPECTION DEPARTMENT OF ANY CHANGE IN THE CONDITION OF THE TEMPORARY REPAIRS.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Construction/Loadline
Issued 18 July 1994 Resolved
MAKE PERMANENT REPAIRS TO THE BOW SHELL PLATE AT THE NEXT DRYDOCK, BUT NO LATER THAN 28FEB97.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Construction/Loadline
Issued 22 November 1993 Resolved
MAKE PERMANENT REPAIRS TO STARBOARD SLOP TANK VENT.
Condition: Unknown
Due 23 December 1993
Resolved 23 December 1993
Construction/Loadline
Issued 22 November 1993 Resolved
PROVIDE CONTAINMENT FOR PORT SLOP TANK VENT.
Condition: Unknown
Due 23 December 1993
Resolved 23 December 1993
Engineering
Issued 22 November 1993 Resolved
REPLACE OR REPAIR PRESSURE RELIEF VALVE OF #2 COMPRESSOR AIR RECEIVER.
Condition: Unknown
Due 2 December 1993
Resolved 3 December 1993
Engineering
Issued 22 November 1993 Resolved
PROVE PROPER OPERATION OF OWS.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 22 November 1993 Resolved
REPLACE FORWARD GANTRY PORTAL FLOOD LIGHTS FEEDER CABLES
Condition: Unknown
Due 23 December 1993
Resolved 3 December 1993
Engineering
Issued 22 November 1993 Resolved
REMOVE OIL FROM ENGINE ROOM BILGES
Condition: Unknown
Due 25 November 1993
Resolved 3 December 1993
Fire Fighting
Issued 22 November 1993 Resolved
REPAINT PULL BOXES TO CO2 CONTROLS FOR ENGINE ROOM.
Condition: Unknown
Due 2 December 1993
Resolved 3 December 1993
Deck/Cargo
Issued 22 November 1993 Resolved
RENEW THE LIMIT SWITCHES FOR THE FORWARD GANTRY TRAVEL. THIS ITEM TO BE COMPLETED PRIOR TO 23DEC93._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 22 November 1993 Resolved
ARC OUT AND REWELD CRACKS IN CRANE RUNWAY SUPPORT PILLAR TOP PLATE AND GUSSETS.
Condition: Unknown
Due 29 November 1993
Resolved 3 December 1993
Construction/Loadline
Issued 22 November 1993 Resolved
PROVIDE CONTAINMENT FOR SLOPS TRANSFER DECK STATION.
Condition: Unknown
Due 23 December 1993
Resolved 23 December 1993
Deck/Cargo
Issued 22 November 1993 Resolved
RENEW STROBE WARNING LIGHT FOR GANTRY TRAVEL AND RENEW LIMIT SWITCHES.
Condition: Unknown
Due 23 December 1993
Resolved 3 December 1993
Construction/Loadline
Issued 22 November 1993 Resolved
RENEW GASKETS FOR WTD'S FOR FWD MACHINERY SPACE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 2 December 1993
Resolved 3 December 1993
Fire Fighting
Issued 22 November 1993 Resolved
Provide evidence that CO2 cylinders serial number 739EK, and 7403EK have been retested IAW 46 CFR 147.65(a). _x001C_ _x001C_ Cylinders were last hydro'd 9/81.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Accommodation/Occupational Safety
Issued 22 November 1993 Resolved
LABEL EMERGENCY ESCAPE EXITS IN ENGINE ROOM.
Condition: Unknown
Due 2 December 1993
Resolved 3 December 1993
Engineering
Issued 23 November 1992 Resolved
HYDROSTATICALLY TEST PRESSURE VESSEL #842013 IN CRANE MACHINERY HOUSE.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Construction/Loadline
Issued 18 December 1991 Resolved
MAKE PERMANENT REPAIRS TO STRUCTURAL MEMBERS AND SIDE SHELL PLATING IN #2 AND #3 PORT WING TANKS. REPAIRS ARE TO BE COMPLETED NOT LATER THAN NEXT AVAILABLE DRY DOCK.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Fire Fighting
Issued 18 December 1991 Resolved
SERVICE FIXED CRANE FIREFIGHTING SYSTEM IN THE PRESENCE OF A MARINE INSPECTOR. FIRE WATCH IS TO BE MAINTAINED DURING CRANE OPERATIONS UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 18 December 1991
Resolved 18 December 1991
Construction/Loadline
Issued 18 December 1991 Resolved
MAKE BARGE AVAILABLE FOR INTERNAL STRUCTURAL EXAM. GAS FREE ALL CONFINED SPACES.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Deck/Cargo
Issued 18 December 1991 Resolved
PROVIDE MECHANICAL PLUGS FOR FUEL OIL CONTAINMENT WHERE MISSING.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Navigation
Issued 18 December 1991 Resolved
Prove operation of the sound powered phone. port side, midship.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Fire Fighting
Issued 5 December 1990 Resolved
PRIOR TO SAILING, PROVIDE ONBOARD AN ADDITIONAL SERVICED B-II FIRE EXTINGUISHER AND ENSURE ALL PORTABLE EXTINGUISHERS ON BOARD HAVE BEEN HYDROED WITHIN THE LAST 5 YEARS._x001C_ _x001C_
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Deck/Cargo
Issued 5 December 1990 Resolved
PROVIDE AND PROVER PROPER OPERATION OF A RELIEF VALVE FOR THE MOLASSES CONTROL AIR TO RELIEVE AT NOT MORE THAN THE PRESSURE VESSEL'S MAWP (200 PSI).
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Electrical
Issued 5 December 1990 Resolved
REPAIR AND PROVE OPERATION OF TE LOW LUBE OIL SHUTDOWN FOR THE CRANE DIESELGENERATOR.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Fire Fighting
Issued 5 December 1990 Resolved
PROVIDE AN INSTRUCTION PLACARD FOR THE CRANE MACHINERY SPACE FIXED CO2 SYSTEM.
Condition: Unknown
Due 5 December 1990
Resolved 5 December 1990
Electrical
Issued 7 December 1988 Resolved
REPAIR AND DEMONSTRATE REVERSE POWER TRIPS.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Electrical
Issued 25 November 1987 Resolved
INSTALL THREE METAL GLOBE PROTECTORS FOR EXTERIOR LIGHTS FROM CRANE LEVEL DOWN.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Accommodation/Occupational Safety
Issued 25 November 1987 Resolved
RETURN SAFETY CHAINS AND STANCHIONS TO SERVICEABLE CONDITION AT CRANE BOARDING PLATFORM AFT.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Accommodation/Occupational Safety
Issued 25 November 1987 Resolved
REPAIR LOWER RAILING AT THE STERN, PORT AND STARBOARD CORNERS.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Deck/Cargo
Issued 25 November 1987 Resolved
REPLACE VENT SCREEN COVER ON #6 VENT STARBOARD SIDE NEAR #6 CONTAINER TIER.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Electrical
Issued 25 November 1987 Resolved
RE-SECURE ELECTRICAL WIRES AT THE PORT MID-SHIP SOUND POWERED PHONE BOX.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Electrical
Issued 25 November 1987 Resolved
REPLACE FLAME SCREENS FOR GENERATING ENGINE VENTS PORT SIDE AFT.
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Unknown
Issued 6 December 1986 Resolved
DEMONSTRATE PROPER SHUTDOWN OF VENTILATION AND MACHINERY IN CRANE HOUSE WHEN FIXED CO2 SYSTEM IS ACTIVATED.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
PROVIDE SERVICING REPORT OF ANNUAL INSPECTION OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
DEMONSTRATE PROPER OPERATION OF AUTOMATIC REMOTE FUEL LEVEL INDICATOR FOR CRANE.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
DEMONSTRATE PROPER OPERATION OF THE FOUR FORWAQRD HEAT SENSORS FOR FIXED CO2 SYSTEM ON CRANE.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
MAKE PERMANENT REPAIRS AS DETERMINED BY CG DRYDOCK INSPECTOR IN WAY OF DAMAGED AREA #3 VOID TANK PORT SIDE AFT 4TH AND 5TH SIDESHELL LONGITUDINAL FRAMES AND AFTER BULKHEAD.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
REPAIR BROKEN WELDS IN #4 BALLAST TANK PORT SIDE AT 3RD MAIN FRAME AND #5 SIDE SHELL LONGITUDINAL.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
REPAIR REACH ROD TO VALVE WHEEL CONNECTION FOR FORWARD STORAGE OVERBOARD VALVE, STARBOARD SIDE.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
REPAIR BROKEN WELDS ON FORWARD STARBOARD WIRE ROPE HOIST ARM AT SUPPORT BRACKET.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
REPLACE MISSING DOGS FOR VENTS ON PORT FORWARD AND PORT AFT VENT DOORS.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Unknown
Issued 6 December 1986 Resolved
DEMONSTRATE PROPER OPERATION OF PRESSURE RELIEF VALVES FOR #1 AND #2 COMPRESSOR TANKS.
Condition: Unknown
Due 6 December 1986
Resolved 6 December 1986
Fire Fighting
Issued 18 December 1985 Resolved
TEST FIXED CO2 SYSTEM FOR CRANE ENGINE ROOM.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Lifesaving
Issued 18 December 1985 Resolved
REPAIR 3 RING BUOY WATERLIGHTS.
Condition: Unknown
Due 18 December 1985
Resolved 18 December 1985
Fire Fighting
Issued 2 May 1985 Resolved
ONE CG APPROVED TYPE C II PORTABLE FIRE EXTINGUISHER SHALL BE INSTALLED OUTSIDE THE CRANE MACHINERY SPACE.
Condition: Unknown
Due 2 May 1985
Resolved 2 May 1985
Deck/Cargo
Issued 2 May 1985 Resolved
THE CRANE'S FUEL OIL TANK VENT SHALL BE FITTED AS FOLLOWS: (1) WITH A RETURN BEND; (2) CLOSURE DEVICE; AND (3) FLAME SCREEN.
Condition: Unknown
Due 2 May 1985
Resolved 2 May 1985
Fire Fighting
Issued 2 May 1985 Resolved
THE FIXED CO2 SYSTEM IN THE CRANE MACHINERY SPACE SHALL BE MADE AVAILABLE FOR FINAL INSPECTION OF SIGNING AND HOOKUP.
Condition: Unknown
Due 2 May 1985
Resolved 2 May 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.