Records from 1984 to 2011. Most recent: inspection, 1 November 2011.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 87
1 November 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4180273
22 January 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3668089
25 September 2009
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3607735
17 March 2009
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3436168
15 November 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2821448
3 August 2006
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2739922
23 March 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2608168
31 January 2006
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2576285
22 November 2005
Administrative Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2539476
7 July 2005
Deficiency Check · Administrative Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2418784
7 April 2005
MTSA Verification · Periodic Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2326084
13 April 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2029774
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963150
20 June 2003
Examination of Repairs · Internal Structural Exam · Hull Examination · Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1785304
3 April 2003
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1767486
1 February 2003
Damage Survey · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1738721
1 February 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1739243
18 January 2002
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1474994
20 February 2001
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1376475
3 February 2000
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361322
29 June 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 441866
16 February 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372507
8 August 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 767758
19 May 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 56547
19 May 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 195617
19 May 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 758067
19 May 1998
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381244
28 March 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 85233
28 March 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 210281
13 February 1998
Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1398841
3 September 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380987
6 September 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357719
25 June 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 538943
18 March 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355698
21 September 1995
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1390119
21 August 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367514
31 July 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 11328
31 July 1995
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1419471
2 December 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 42057
21 September 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394184
8 October 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 657425
30 September 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 499300
22 September 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1397958
13 August 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 507815
22 June 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 657421
20 June 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 129962
20 June 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 225814
20 June 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 231325
4 June 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 846629
6 May 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 26122
6 May 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391842
26 February 1993
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1403590
4 February 1993
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373795
9 October 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1267652
30 September 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 514523
14 August 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958495
9 August 1992
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 950166
7 August 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 657418
6 August 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 143858
5 August 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 109889
30 April 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 458093
12 March 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 530964
12 February 1992
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958211
26 December 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 499097
23 October 1991
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1253379
5 June 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1242000
24 April 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1241317
6 February 1991
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233184
6 December 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 500272
7 November 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1230647
19 April 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 531521
28 November 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1234259
26 November 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 916175
27 July 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 479216
2 June 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 478267
20 April 1989
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037704
20 January 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 494435
15 December 1988
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1035857
17 August 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 521090
23 April 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 469605
9 April 1988
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1041240
22 December 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1317054
8 January 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1317644
18 December 1986
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1312646
25 April 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 998756
15 June 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 471792
22 December 1984
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1288481
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 April 2009
Resolved
DT 273 failed to undergo an annual inspection in 2007. Title 46 CFR 91.27-1(a) requires vessels to undergo an annual inspection with three months beofe or after each anniversary date. The COI became invalid on November 3, 2007.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2009
Resolved 29 May 2009
Resolution: Sector Seattle issued letter of warning.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 April 2005
Resolved
Diagnose and make proper repairs to "green" cargo pump prime mover. Currently, there appears to be excessive crank case blow by which potentially presents a fire hazard. 46 CFR 32.50. Correct to the satisfaction of the attending marine inspector.
Due 7 May 2005
Resolved 7 July 2005
Resolution: Corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 7 April 2005
Resolved
Provide and install port lights in Cargo pump house to enable tankerman ability to view cargo pump pressure gauges from clutch location. Complete to the satisfaction of the attending marine inspector by next scheduled drydock NLT 20FEB06.
Condition: Unknown
Due 20 February 2006
Resolved 20 February 2006
Resolution: Sold To Dunlap towing and converted to a deck cargo barge house removed.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 June 2003
Resolved
Replace non-metallic flex lines between cargo pump discharges and the cargo pump discharge gauges. Hose lengths to be reduced to not more than 30 inches with the remainder of the sensing line made up with metallic tubing/piping. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 20 July 2003
Resolved 1 July 2003
Engineering › Fuel Oil Service System › Filter
Issued 20 June 2003
Resolved
Replace all plastic drain plugs on prime mover/generator engine Racor filters with metallic solid plugs.
Condition: Improper Installation
Due 11 July 2003
Resolved 1 July 2003
Engineering › Fuel Oil Service System › Hose
Issued 20 June 2003
Resolved
Replace all non-metallic flex hoses installed on prime mover/generator engines (blue braided jackets) for fuel/lube oil, with hose meeting SAE J1942.
Due 11 July 2003
Resolved 1 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 20 June 2003
Resolved
Repair and prove proper operation of all valve position indicators on all cargo and misc. valve stems throughout the cargo deck.
Condition: Improper/Lack of Maintenance
Due 11 July 2003
Resolved 1 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 20 June 2003
Resolved
Re-label all valves located throughout the cargo deck.
Due 11 July 2003
Resolved 1 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 20 June 2003
Resolved
Re-label aft emergency cargo pump shut-down station.
Due 11 July 2003
Resolved 1 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 20 June 2003
Resolved
Stencil all cargo piping with most recent hydrostatic test date (6/17/03).
Due 11 July 2003
Resolved 1 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 20 June 2003
Resolved
Have all cargo pump discharge gauges calibrated or renewed.
Due 11 July 2003
Resolved 1 July 2003
Deck/Cargo › Towing
Issued 20 June 2003
Resolved
Renew the existing emergency towing line/cable prior to carriage of cargo. LEGACY COMPONENT DESC: Towline
Due 20 July 2003
Resolved 1 July 2003
Stability › Unintentional Flooding
Issued 20 June 2003
Resolved
Provide verification of compliance with 33CFR 155.240 (damage stability information).
Due 11 July 2003
Resolved 1 July 2003
Documentation › Safety/Response Plans/Programs › Damage Stability Calculation Program/Plans
Issued 20 June 2003
Resolved
Provide verification of compliance with 33 CFR 155.1060 (Response exercises).
Due 11 July 2003
Resolved 1 July 2003
Construction/Loadline › Hull › Side Shell
Issued 1 February 2003
Resolved
Prior to loading cargo, gas free the #2S cargo tank, locate source of leak in starboard side and make permanent repairs.
Condition: Damaged By Earlier Event
Due 10 February 2003
Resolved 3 February 2003
Construction/Loadline
Issued 19 May 1998
Resolved
Make permanent repairs to 3" crack port sideshell in tank #2P. Not to carry cargo in tank until repairs are made to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Electrical
Issued 6 September 1996
Resolved
Prove proper operation of generator prime mover overspeed trip device, per 46 CFR 111.12-1.
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Construction/Loadline
Issued 31 July 1995
Resolved
Make permanent repairs to the damaged area found with cracks in shell plateand framing located on the starboard side in the forward house between frames #8 & 14. The temporary patch is to be removed and permanent repairsshall consist of cropping and renewing all damaged material as original.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Construction/Loadline
Issued 6 May 1993
Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN # 2 PORT CARGO TANK. PRIOR TO ANY CARGO OPERATIONS.
Condition: Unknown
Due 30 June 1993
Resolved 7 May 1993
Construction/Loadline
Issued 6 May 1993
Resolved
MAKE PERMANENT REPAIRS TO THE FRACTURE IN THE BOTTOM PLATE IN THE #2 PORT CARGO TANK, IN WAY OF THE #6 TRANSVERSE FRAME & #1 INBOARD BOTTOM LONG, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. BARGE IS NOT TO CARRY ANY CARGO IN THE #2P CARGO TANK UNTIL PERMAMENT REPAIRS ARE COMPLETED.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Construction/Loadline
Issued 4 February 1993
Resolved
MAKE PERMANENT REPAIRS TO SIDESHELL, #3 STARBOARD CARGO TANK, IN WAY OF FRAME #8 AND 5' DRAFT MARK.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Construction/Loadline
Issued 9 August 1992
Resolved
GAS FREE AND EFFECT REPAIRS TO DAMAGE IN CARGO TANK #3 STARBOARD.
Condition: Unknown
Due 14 August 1992
Resolved 14 August 1992
Deck/Cargo
Issued 23 October 1991
Resolved
PROVIDE FLAME CUPS ON ALL RANCOR FUEL FILTERS.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Fire Fighting
Issued 23 October 1991
Resolved
SERVICE OR REMOVE THE SEMI-PORTABLE DRY CHEMICAL FIRE EXTINQUISHER.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Deck/Cargo
Issued 23 October 1991
Resolved
REPLACE THE FLAME SCREEN ON THE STARBOARD SIDE OF THE PV VALVE TO #6 CARGO TANK.
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Construction/Loadline
Issued 24 April 1991
Resolved
DRYDOCK, GAS FREE AND MAKE PERMANENT REPAIRS TO THE FRACTURED BOTTOM PLATE IN NUMBER 2C CARGO TANK. NUMBER 2C CARGO TANK IS TO REMAIN EMPTY AND ISOLATED FROM THE CARGO MAIN UNTIL PERMANENT REPAIRS ARE COMPLETED.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Fire Fighting
Issued 15 December 1988
Resolved
SERVICE BOTH HAND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988
Fire Fighting
Issued 15 December 1988
Resolved
HYDRO TEST BOTH PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988
Navigation
Issued 15 December 1988
Resolved
HYDRO TEST TO 300 PSI THE INSTALLED AIR RECEIVER
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988
Accommodation/Occupational Safety
Issued 15 December 1988
Resolved
REPLACE TOP MOST BROKEN LIFE LINE, PORT AND STARBOARD BOW.
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988
Navigation
Issued 15 December 1988
Resolved
TEST AIR RECEIVER RELIEVING DEVICE. DEVICE TO LIFT AT OR BELOW 200 PSI.
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988
Fire Fighting
Issued 15 December 1988
Resolved
PROVIDE ONE ADDITIONAL FIRE EXTINGUISHER FOR A MINIMUM OF THREE B-II DEVICES. ONE TO BE AT THE EXIT OF MACHINERY SPACE, TWO ON DECK.
Condition: Unknown
Due 15 December 1988
Resolved 15 December 1988
Unknown
Issued 22 December 1987
Resolved
REPAINT SAFETY AND WARNING SIGNS ON PORT AND STARBOARD SIDES OF VESSEL.
Condition: Unknown
Due 22 December 1987
Resolved 22 December 1987
Construction/Loadline
Issued 22 December 1987
Resolved
REPAIR EYEBOLT ON NO. 6 PORT TANK COVER.
Condition: Unknown
Due 22 December 1987
Resolved 22 December 1987
Navigation
Issued 22 December 1987
Resolved
RELOCATE STERN LIGHT TO CENTERLINE OF VESSEL IN ACCORDANCE WITH APPROVED PLANS DATED 18 DECEMBER 1984.
Condition: Unknown
Due 22 December 1987
Resolved 22 December 1987