MAURY USCG vessel records
← All vessels

KIMBERLY C

Built
1966
Last inspected
21 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 21 July 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7210783
WDP2209
Flag
UNITED STATES
Maury page id
psix-91504

Documentation record

Registered dimensions (L × B × D)118.0 ft × 31.5 ft × 15.9 ft
Registered tonnagegross 180 / net 122
ITC dimensions (L × B × D)118.0 ft × 31.5 ft × 15.9 ft
ITC tonnagegross 382 / net 114
BuilderNOLTY J. THERIOT · GOLDEN MEADOW, LA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 6 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it180 - Regulatory (Subpart C or D), Gross Ton
382 - Convention (Subpart B), Gross Ton
122 - Regulatory (Subpart C or D), Net Ton
114 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 43 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KENDALL J HEBERT Towing Vessel · MISLE 596470 · 1 October 2025 · activity 8244994SIRIUS Freight Ship · MISLE 1110087 · 23 August 2021 · activity 7298306PACIFIC AVENGER Towing Vessel · MISLE 152885 · 29 March 2008 · activity 3174632DT 273 Freight Barge · MISLE 245682 · 31 July 1995 · activity 11328

Inspection history · 43

21 July 2026 Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8453428
12 February 2026 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8309779
22 December 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8286513
1 October 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8244827
1 October 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8244994
21 May 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8152669
13 January 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8062923
12 August 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7979843
13 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7608782
31 August 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7301331
28 August 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7298579
23 August 2021 Administrative Inspection · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7294783
23 August 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7298306
22 July 2021 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7241091
23 March 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6930456
29 February 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6918188
19 December 2019 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6876858
30 July 2019 Administrative Inspection · Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6767076
27 May 2016 MTSA Verification · Industry Initiated Exam · Administration · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5888356
20 April 2016 Industry Initiated Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5854938
29 December 2015 Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5791629
26 March 2015 Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5091087
3 May 2013 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586301
7 March 2013 Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4544717
21 March 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3976150
9 September 2010 Administration
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3847061
23 March 2010 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701491
22 February 2010 Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3683811
29 March 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3174632
14 November 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3098423
10 November 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3097861
16 February 2007 MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2873228
27 February 2006 Deficiency Check · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2595831
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963200
23 March 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 106451
24 October 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 3433
16 June 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 116211
6 June 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 14121
31 July 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 11328
24 August 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 369903
2 February 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 19830
27 August 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1269792
31 July 1992 Inclining Experiment
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1260003

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 December 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI was informed that vessel has suspected line wrapped around STBD shaft. Submit Permit to Proceed request if desired to transit to repair facility and provide diver and class report attesting to the repair of STBD shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2025
Resolution: Received info from ABS and dive report. All sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 July 2021 Resolved
Emergency lighting must be provided for all internal crew workign spaces to provide light source to facilitate egress from space. MI noticed during test of emergency lighting for engine room was not opertional. Vessel must fix emergency lighting to provdie adequate safety.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 July 2021
Resolved 22 July 2021
Resolution: Engineer was able to replace batteries was in working condition prior to leaving vessel.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010

Recorded names · 1

SCORPIUS (2008–2021). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.