Inspection history · 42
7 April 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8326923
12 February 2026
Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299362
22 August 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8215973
1 May 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8172183
12 August 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7976210
19 March 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7881983
6 March 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7875203
11 September 2023
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7787931
27 July 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7754252
18 January 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7627153
3 October 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7570594
12 May 2021
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7195599
24 September 2020
Deficiency Check · Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7064754
8 July 2020
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7006616
26 March 2020
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6932026
16 December 2019
DAPI Audit
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6884654
24 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6547440
5 March 2018
Administration · Industry Initiated Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6366091
21 April 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5145384
19 September 2013
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4719750
18 October 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4466950
18 October 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4466981
28 January 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3936315
3 January 2011
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3919826
5 July 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3524930
16 January 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3398307
5 January 2009
Administration · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3389110
10 August 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3295912
30 October 2006
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2812593
15 June 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2680972
3 December 2005
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2545819
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963207
3 November 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 168805
9 October 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 198513
9 October 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754722
17 July 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754585
26 March 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 17732
15 July 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 204572
2 February 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 113168
19 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 710899
14 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 370601
5 August 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 109889
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2026
Resolved
Alarms must be visible and audible at each operating station. MI observed that the starboard alarm panel was not giving any visual indication. O/o shall repair or replace alarm panel so that it produces visual and audible alarms at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 10 June 2026
Resolution: O/o provided documentation of visual and audible alarms at the operating station for the starboard alarm panel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 May 2026
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either:(1) Automatic, battery-operated with a duration of no less than 2 hours; or(2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. MI observed that there was no emergency lighting provided in the forepeak, which is a designated escape route, and no emergency lighting was installed in the main deck crew berthing area. O/o shall install an approved emergency lighting system in the forepeak and in the main deck crew berthing areas, consisting of either automatic battery-operated fixtures or approved phosphorescent adhesive strips.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 5 June 2026
Resolution: O/o installed non-electric, phosphorescent adhesive lighting strips along escape routes.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 21 May 2026
Resolved
Each towing vessel must carry on board and maintain…Charts or maps. Marine charts or maps of the areas to be transited, published by the National Ocean Service (NOS), the ACOE, or a river authority that satisfy the following requirement: The charts or maps must be of a large enough scale and have enough detail to make safe navigation of the areas possible. Vessel was found operating with electronic charting system (Rosepoint Coastal Explorer) that does not have a type approval or manufacturer’s declaration of conformity and therefore does not meet the chart equivalency requirement. O/o is required to have up-to-date paper charts or utilize an electronic charting system that has a type approval or manufacturer's declaration of conformity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 2 June 2026
Resolution: Vessel operator provided photograph of Rose Point ECS installed on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 May 2026
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. A 40-B portable fire extinguisher must be located near the storage room or cabinet. MI observed flammable materials improperly stored, and no 40-B portable fire extinguisher installed nearby. O/o shall properly store all flammable and combustible material products and install a 40-B portable fire extinguisher in the immediate vicinity, or remove the flammable and combustible material products from the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 2 June 2026
Resolution: O/o provided documentation of removal of flammable products.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 May 2026
Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. MI noted vessel did not have means to take blood pressure readings. O/o shall demonstrate ability to take blood pressure readings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 2 June 2026
Resolution: O/o provided documentation of vessel crew ability to take blood pressure readings.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 April 2026
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. MI noted midship starboard and port light fixtures improperly installed. O/o shall properly install light fixtures to ensure safety and sufficient lighting.
46 CFR 143.410(a)
46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 2 June 2026
Resolution: O/o provided documentation of properly installed lighting fixtures on port and starboard side.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 April 2026
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI noted extension cord utilized as permanent electrical connection for mechanical ventilation of lazarette. O/o shall remove extension cord and hardwire the electrical connection for the mechanical ventilation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 2 June 2026
Resolution: O/o provided documentation of properly wired electrical connection for ventilation system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including exhaust manifolds, and turbochargers, must be insulated.
#1 MDE Found with section of lagging missing from exhaust header.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2025
Resolved 15 May 2025
Resolution: Recvd photos
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 May 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting must be either...
Automatic, battery-operated with a duration of no less than 2 hours; or Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
Pilothouse found without means of emergency lighting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2025
Resolved 15 May 2025
Resolution: Recvd photos
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions.
Expired medication found in first aid cabinet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2025
Resolved 15 May 2025
Resolution: Recvd photos
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Spotlight on top of the wheelhouse had a splice in the wiring that was not in a junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2023
Resolved 11 September 2023
Resolution: During DDX inspection on 9/11/23 inspector observed stray wire removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2022
Resolved
The master must ensure that all life-saving equipment is properly maintained and ready for use at all times. MI's noted that 02 life-rings on bridge were degraded and not effective for lifesaving. Replace and add appropriate markings and retro tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 19 October 2022
Resolution: O/o obtained new life buoys, all have been properly marked with retro reflective tape and the vessel name and port are marked on the buoys as well. All in apparent good order.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 12 May 2021
Resolved
Provide means to test the following alarms; Main engine low lubricating oil pressure; Main engine high cooling water temperature; Auxiliary generator engine low lubricating oil pressure; Auxiliary generator engine high cooling water temperature; High bilge levels; and Low fuel level, if fitted with a day tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 21 July 2021
Resolution: Recieved photographic evidence of repair.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2021
Resolved
Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Received documentary evidence.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2021
Resolved
Update Certificate of Documentation (COD) with international tonnage from the vessel's International Tonnage Certificate.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2023
Resolution: Vessel requested to amend their COI so that they could not operate internationally.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 May 2021
Resolved
Repair oil leak on port generator hose to filter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2021
Resolved 21 July 2021
Resolution: Recieved photographic evidence of repair.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 12 May 2021
Resolved
Crop and renew 03 bulkhead stiffeners identified on port bulkhead IVO aft entrance to superstructure from Main deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Received photographic evidence.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2021
Resolved
Show that the Fire-detection systems is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Recieved documentary evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2021
Resolved
Replace missing valve handles for STBD Main Engine oil filter and fuel transfer discharge line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Recieved photographic evidence.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 May 2021
Resolved
Remove water from lazerette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Recieved photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2021
Resolved
For towing vessels with berthing aboard, a sufficient number of additional lifejackets must be carried so that a lifejacket is immediately available for persons at each normally manned watch station. Provide 01 additional lifejacket as indicated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Recieved photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 May 2021
Resolved
In addition to the immersion suits required under paragraph (a)(1) of this section, each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch in, or assigned to, the station or site at one time. However, an immersion suit is not required at a station or site for a person whose cabin or berthing area (and the immersion suits stowed in that location) is readily accessible to the station or site. Provide 04 additional immersion suits (02 on bridge).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Recieved photographic evidence.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 May 2021
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 8 July 2021
Resolution: Received documentary evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2021
Resolved
Replace missing exhaust lagging on STBD main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 6 August 2021
Resolution: Recieved photographic evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2021
Resolved
Replace missing flywheel covers on main prop engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 15 July 2021
Resolution: Recieved photographic evidence.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 May 2021
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 8 July 2021
Resolution: Received documentary evidence.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2021
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Relabel breaker panels indicated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 8 July 2021
Resolution: Received documentary evidence.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 May 2021
Resolved
Each space where crew may be quartered or normally employed must have at least two means of escape. Adjust escape hatch so that it may be readily opened from the inside.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 8 July 2021
Resolution: Received documentary evidence.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 16 December 2019
Resolved
Sause Brothers DER provided documentation that all Sause Brothers supervisors have received the annual 1-hour drug and alcohol (EAP) training required by 46 CFR § 16.401.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 January 2020
Resolved 26 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 September 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 26 March 2020
Resolution: AIS is properly broadcasting.
Accommodation/Occupational Safety
Issued 14 September 1994
Resolved
ON 14SEP94, THE M/V MIKI HANA, OPERATED BY SAUSE BROTHERS INC, WAS OPERATING AT PIER 20, HONOLULU, HI. A USCG BOARDING OFFICER FOUND THE M/V MIKI HANA WAS EQUIPPED WITH INSTALLED TOILET FACILITIES AND WAS NOT EQUIPPED WITH AN OPERABLE TYPE III MARINE SANITATION DEVICE.
Condition: Unknown
Due 30 September 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past