Records from 1993 to 2026. Most recent: inspection, 6 August 2026.
Inspection history · 67
6 August 2026
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8456502
22 March 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7655020
21 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7415431
11 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7152917
27 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961801
15 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6953785
16 October 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6843591
16 October 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6845339
5 July 2019
COI Inspection · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6736942
26 April 2019
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6671128
31 August 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6528582
29 June 2018
Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6459442
12 October 2017
MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6285860
18 October 2016
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6024549
26 September 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6009892
31 May 2016
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5893049
18 November 2015
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5765899
29 December 2014
Administrative Inspection · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5045250
10 December 2014
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5037510
30 September 2014
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4995002
8 January 2014
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4779912
18 November 2013
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4758857
21 August 2013
Deficiency Check · Drydock Exam · Cargo Tank Internal · MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4685069
19 November 2012
Annual Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4486787
31 August 2012
Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4426978
18 July 2012
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4383186
18 July 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4383295
25 May 2012
COI Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4321489
13 January 2012
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222204
9 August 2011
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4110285
30 November 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3901090
23 November 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3900545
4 November 2010
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3884104
8 August 2008
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3285397
10 July 2008
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3327384
22 May 2008
MARPOL Annex I Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3205722
26 April 2007
Annual Inspection · Deficiency Check · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2916888
10 December 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2849616
24 July 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2723432
16 May 2006
COI Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2622387
3 June 2005
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2378048
11 May 2005
MTSA Verification · MARPOL Annex I Examination · Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2354504
12 May 2004
Periodic Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2065658
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963101
23 May 2003
Annual Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1802112
14 May 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1625663
20 January 2002
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1492436
22 May 2001
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1065166
18 May 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1453950
28 June 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1050641
3 November 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 168805
26 June 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1375884
24 November 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 6255
24 November 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 180584
1 July 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1418367
25 June 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1434603
6 October 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 534338
19 September 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 436502
23 May 1996
Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1380513
6 December 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 514800
17 July 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1417800
21 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 529252
10 September 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 151096
2 August 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1389866
11 April 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 485540
20 August 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 464548
3 August 1993
Hull Examination · MARPOL Annex I Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1401740
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 March 2023
Resolved
Operational tests and checks of all safety and limit controls, combustion controls, programming controls, and safety relief valves must be conducted by the owner, chief engineer, or person in charge at the inspection for certification, periodic inspection, and when directed by the Officer in Charge, Marine Inspection, to determine that the control components and safety devices are functioning properly and are in satisfactory operating condition.
Thermal fluid heater was INOP & tagged out.
Prior to carrying grade "E" cargo, OCMI must witness all operational tests required of thermal fluid heater.
46 CFR 61.30-20
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2026
Resolution: Vessel has been removed from service to be converted to a drydock.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2022
Resolved
Electric installations must ensure protection of passengers, crew, and vessel from electrical hazards.
Missing cap on the thermal fluid oil tank level sensor, causing exposed wiring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 22 March 2022
Resolution: Installed new cap.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 21 March 2022
Resolved
Inland barges must have appropriate equipment and supplies ready for immediate use to control and remove on-deck oil cargo spills.
The spill kit on board the barge was missing required equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2022
Resolved 21 March 2022
Resolution: Vessel provided new skill kit with required supplies.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 March 2022
Resolved
The owner, master, or person-in-charge must ensure that portable fire extinguishers are inspected and maintained in accordance with NFPA 10.
Fire extinguishers on board had not been inspected by a certified or licensed fire extinguisher servicing agency in the last year.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2022
Resolved 22 March 2022
Resolution: Provided evidence of certified fire extinguishers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2022
Resolved
Each lighting fixture in the weather or exposed to splashing water must be waterproof.
Broken glass light enclosure, located by the entrance to the engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 March 2022
Resolved 21 March 2022
Resolution: Replaced with new glass enclosure.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 11 March 2021
Resolved
Vessel must have a stability letter before it is placed in service. Vessel does not have stability letter/booklet information onboard or available and the information is not present on the COI. Vessel must make stability letter/booklet information made available.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2021
Resolved 13 April 2021
Resolution: Vsl provided a copy of the stability letter.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2021
Resolved
Vessel with a capacity of 250 or more barrels (10500 gallons) of oil shall provide transfer procedures. Vessel has a capacity of approx.. 15000 gallons of transferable fuel oil and was not able to provide transfer procedures. Vessel must make transfer procedures available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2021
Resolved 16 April 2021
Resolution: Vsl provided copy of fuel transfer procedures and will make a copy available at all times onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2021
Resolved
Vessel Response Plan must include a list of COTP zones in which it intends to handle, store, or transport oil. The current Vessel Response Plan does not list Houma as an authorized operating COTP zone.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2021
Resolved 19 April 2021
Resolution: Vsl provided copy of updated VRP with Houma listed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2021
Resolved
Hydraulic system must be free of all leaks. There is a hydraulic leak on the ballast water pump supply line before the pump motor in the ballast pump room. Vessel must correct the leak.
Due 11 April 2021
Resolved 17 March 2021
Resolution: Hydraulic leak was corrected, system test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 March 2021
Resolved
Lights in auxiliary machinery space must be arranged so the failure of one branch circuit does not leave the area without light. Two overhead lights in the ballast
pump room were extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2021
Resolved 18 March 2021
Resolution: Lights were replaced, all lights operational in ballast pump room.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 11 March 2021
Resolved
Warning sign shall be displayed to warn persons. The starboard side warning sign was worn and weathered and could not be easily read. Vessel must provide legible warning sign on the starboard side.
Action required: 10 - Deficiency Rectified
Due 11 April 2021
Resolved 11 March 2021
Resolution: Warning sign was repainted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 August 2018
Resolved
Each tank vessel must undergo dry dock inspections in accordance with table 31.10-21(a). Vessel shall be taken out of service until the vessel can be placed in a gas free status. Vessel representative shall submit a letter to CG stating the vessel is taken out of service, and when and how the vessel will be transported to the clean facility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 September 2018
Resolution: Barge has been taken out of service and has surrendered the COI.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 June 2018
Resolved
Cargo residue was found throughout the #1 P&S void space. Vessel was issued an CG 835v requiring to gas free the #1 cargo tanks and conduct an air test. To be conducted prior to credit Internal Structural Exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 June 2018
Resolution: Attending MI witnessed air test. Air test revealed that there was no cargo leak.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 June 2018
Resolved
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. As a result from a previous incident, cargo migrated into the the #1 port & starboard void tanks; whereas, cargo residues congealed to the structural members and internal plating. The void tanks must be effectively cleaned to the satisfaction of the local OCMI. To be completed prior to credit ISE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 July 2018
Resolution: O/O cleaned the #1 port & starboard void tank to the satisfaction of the attending marine inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 19 October 2016
Resolved
#1 and #2 cargo pump relief valves were not tested annually. 46 CFR 35.35-70(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 20 October 2016
Resolution: Received, reviewed and accepted sastisfactory inspection/test report for #1 and #2 cargo pump relief valves.
Electrical › Electric Supply System (service) › Cable
Issued 18 November 2015
Resolved
Wire must be in an enclosure. Spliced wires on cargo pumps 1 and 2 prime movers were not in an enclosure. 46 CFR 111.60-11(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 8 December 2015
Resolution: Received pictures of newly installed junction box for spliced wires on cargo pump engine.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 18 November 2015
Resolved
Provides a visual indication of the liquid level in the in the cargo tank when the cargo 46 when the cargo level is within 1.0 meter (3.28 feet)of the tank top. Rising stick near cargo tank 2S does not extend fully and must be fixed or replaced. CFR 39.20-3(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 8 December 2015
Resolution: Received picture of newly installed and working rising stick on #2 STBD cargo tank.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 29 December 2014
Resolved
Ground detection is required on 120v and 440v distribution panels. Eliminate grounding that causes flickering in detection panels. 46CFR111.05-21
Due 6 January 2015
Resolved 2 January 2015
Resolution: During the def check on 2Jan15 it was observed that the ground was eliminated and that the ground detection was operating properly.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 December 2014
Resolved
Every portable extinguisher shall be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels, and which is arranged to provide quick and positive release of the extinguisher for immediate use. Vessel must repair its broken extinguisher bracket between the cargo manifolds. 46CFR162.028-3(g)
Due 6 January 2015
Resolved 2 January 2015
Resolution: During the def check on 2Jan15 it was observed that the extinguisher mounting bracket was replaced with a manufacturer approved bracket.
Deck/Cargo › Cargo Heating › General
Issued 29 December 2014
Resolved
Thermal fluid heater operational tests and checks of all safety relief valves must be conducted by the owner, chief engineer, or person in charge at the periodic inspection. Tests of safety relief valves on the thermal fluid heater have not been conducted. 46CFR61.30-20
Due 16 January 2015
Resolved 5 January 2015
Resolution: Received paperwork stating that the two safety relief valves on the thermal fluid heater were tested and are operating properly.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 30 September 2014
Resolved
Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the MAWP. The equipment test of the vessel's cargo piping required under 33CFR156.170(c)(4) was conducted at 100 psi. Correct MAWP (125 psi) determined by the pressure at which the transfer piping relief valve is set. Test to 1.5 times the MAWP or approved alternative.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2014
Resolution: Received Certificate of Inspection and Test reflecting a hydrostatic pressure test of the cargo piping at 225 psi.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 30 September 2014
Resolved
Annual testing of nonmetallic transfer hose (Ser. No. 137341-01) required under 33CFR156.170(c)(1)(iii), last conducted on 15May2013. Test or replace transfer hose prior to use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2016
Resolution: Received Certificate of Inspection and Test, dated 1 Oct 2014, stating that the transfer hose had been tested at 225 psi.
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2014
Resolved
Vessel reported flooding in #2 wing voids. Vessel is authorized a single transit to a reception facility to offload its entire cargo load. After complete discharge, the vessel is authorized a single transit to a cleaning facility. After cleaning, vessel is authorized to proceed to drydock and be made available for CG inspection of hull damage IVO #2 void tanks. Prior to loading cargo.
Action required: 705 - Other - as specified
Resolved 30 January 2014
Resolution: Received ABS Report #NY2530749 stating that all repairs have been examined, tested and considered satisfactory.
Electrical › Electric Generation Source (emergency) › Ground Detection
Issued 19 September 2013
Resolved
Vessel must demonstrate proper operation for 440 volt ground detector panel. Provide ABS plans for current 440 volt ground detection panel. 46 CFR111.05-21(b). Extended due date from 20OCT to 10NOV per vessel request and approval from [name withheld].
Due 10 November 2013
Resolved 30 October 2013
Resolution: Visually inspected and tested the 440 volt ground detection panel installation. Test satisfactory, vessel ground detection system operating properly.
Deck/Cargo › Cargo Heating › General
Issued 19 September 2013
Resolved
Vessel must lock out and tag out the thermal fluid heater until vessel demonstrates proper operation. 46 CFR 61.30-20 Rectify prior to cargo operations involving use of thermal fluid heater.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2013
Resolution: Vessel operated thermal fluid heater, tested all safety shutdowns and examined external condition. Test Satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 19 September 2013
Resolved
Cargo discharge pressure gauge shall be installed at a location point visible with respect to the pump controls. Vessel does not have cargo discharge pump gages installed. 46 CFR 32.50-5
Due 20 October 2013
Resolved 27 September 2013
Resolution: Vessel moved cargo gauges back to its original position making it visible from the cargo pump room for the PIC.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 18 July 2012
Resolved
Vessel must repair anchor to the satisfaction of USCG prior to cargo ops.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2012
Resolved 23 July 2012
Resolution: [name withheld] provided a repair report form GMD Bayonne Shipyard stating that the barge COLUMBIA''s anchor has been repaired and is working . CG 835 is cleared.
Deck/Cargo › Cargo Heating › General
Issued 13 January 2012
Resolved
Do not use Thermal Fluid Heater for cargo transportation until attended by a CG Marine Inspector or ABS Inspector to verify safety shutdowns on system.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 20 January 2012
Resolution: Received ABS Report from barge rep attesting that safety shutdowns were tested and considered satisfactory.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 January 2012
Resolved
Vessel was outside of the allowed 90 day before/after window for inspection in accordance with the COI anniversary date. The COI date is 08 Aug 2011, your inspection was not completed until 13 Jan 2012.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2012
Resolved 23 January 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 4 November 2010
Resolved
Repair the STBD out board cargo pump emergency shutdown prior to cargo operations w/ that cargo pump. No later than 18Nov2010.
Action required: 705 - Other - as specified
Due 18 November 2010
Resolved 5 November 2010
Resolution: Received ABS class report # NY1905042 stating the affected electrical shut down device on the stbd cargo pump engine was repaired at this time, operational test conducted and found in satisfactory condition.
Deck/Cargo › Cargo Heating › General
Issued 11 August 2008
Resolved
Conduct field test procedures IAW USCG-approved test procedures on the fired thermal fluid heater.
Due 11 September 2008
Resolved 11 September 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 26 April 2007
Resolved
Complete routine maintenance on stbd cargo pump prior to carrying cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 27 April 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 26 April 2007
Resolved
Replace gasket on port cargo pump engine and clean or replace lagging on engine exhaust prior to operating cargo pump engine.
Due 30 April 2007
Resolved 27 April 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 April 2007
Resolved
Re-seal viewing ports on stbd deck shack.
Due 30 April 2007
Resolved 27 April 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 25 May 2006
Resolved
Renew the damaged hydraulic line on the starboard prime mover supply line for cooling fan motor.
Due 25 June 2006
Resolved 26 May 2006
Resolution: Observed renewed hose.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 25 May 2006
Resolved
Test the overspeed and low lube oil shutdown on the generator.
Due 25 June 2006
Resolved 26 May 2006
Resolution: Witnessed satisfactory tests of overspeed and lube oil shutdown on the generator.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 May 2006
Resolved
Stencil cargo piping with date of hydro testing in accordance with 33 CFR 155.800
Due 25 June 2006
Resolved 26 May 2006
Resolution: Observed hydro test date and mawp stenciled on the piping.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 25 May 2006
Resolved
Replace all non-metallic, fiber-reinforced hose lines (includes fuel, lube oil, hydraulic oil) with SAE-J1942 Coast Guard approved hoses.
Due 25 July 2006
Resolved 24 July 2006
Resolution: Vessel representative provided documentation attesting the fact that all the new hoses installed complied with SAE J1942 Standards. Observed new hydraulic/fuel/lube oil hoses and compared hose numbers with list provided by [name withheld].
Electrical › Electrical Distribution System (service) › Cable
Issued 11 May 2005
Resolved
Re-new elbow for electrical conduit on low level switch for Thermal Fluid Heater (TFH) expansion tank located port side. 46 CFR 111.105-17. Correct to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Due 13 June 2005
Resolved 3 June 2005
Resolution: Corrected.
Documentation
Issued 3 August 1993
Resolved
PROVIDE ON BOARD A VALID LOAD LINE CERTIFICATE.
Condition: Unknown
Due 20 August 1993
Resolved 17 August 1993