Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
Inspection history · 24
1 June 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8385552
5 November 2025
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8264773
6 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8128583
13 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8032285
14 May 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7911684
30 May 2023
In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7700952
21 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7595488
4 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7419369
16 December 2021
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7369376
27 May 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7205702
5 February 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7138028
2 December 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7105249
13 November 2020
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7094920
29 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6955831
12 June 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6710737
1 December 2018
Deficiency Check · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6591018
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6514110
20 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6449006
9 June 2017
Attraction Vessel Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6173211
29 March 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6109561
24 March 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6199092
21 November 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6043605
4 August 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5962369
1 June 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5892566
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 June 2026
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel's Certificate of Documentation was expired.
46 CFR 67.313(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 1 June 2026
Resolved 2 June 2026
Resolution: Received application. See Narrative.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2026
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Forward and midships life rings had faded vessel name.
46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 2 June 2026
Resolution: Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2026
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Forward and midships life rings had degraded retroreflective material.
46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 2 June 2026
Resolution: Renewed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 June 2026
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have record of monthly portable fire extinguisher inspections being conducted.
46 CFR 176.810(b)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 3 June 2026
Resolution: Rec'd photo of monthly inspection log.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical outlet in aft salon bar area was daisy-chained creating potential electrical hazard.
46 CFR 183.200(b)
Action required: 10 - Deficiency Rectified
Due 1 June 2026
Resolved 1 June 2026
Resolution: Cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 12 Adult type 1 PFD's did not have approval information attached. Vessel is limited to carriage of 122 adults. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 14 May 2025
Resolution: o/o purchased 12 new type 1 PFD's and labeled, placed onboard.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 May 2025
Resolved
A power-driven fire pump shall be installed on each mechanically propelled vessel which is permitted to carry more than 49 passengers. Fire pump electric controller box had broken faceplate. 46 CFR 181.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 14 May 2025
Resolution: Faceplate replaced with new. all sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 6 May 2025
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. No spanner wrench was located at hydrant in accommodation space. 46 CFR 181.310(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 14 May 2025
Resolution: Spanner wrench was placed at interior hydrant location.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Charts of large enough scale to make safe navigation possible. Vessel did not have up-to-date charts. 46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 14 May 2025
Resolution: O/O purchased new charts dated 06MAY25. all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2023
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Head pump installed with temporary extension cord as main power source.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: MI's verified extension cord was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2023
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. The fire pump switch mount was broken. The switch was dangling free at the entrance to the the engine room.
46 CFR 183.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: MI's verified fire pump switch was mounted
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 May 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. AFT exit was unmarked and not readily apparent to a person in those spaces.
46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: MI's verified "Exit" signs were marked
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 30 May 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel is missing placards for different manufacturers of life jackets.
46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: MI's verified placards were in place
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 May 2023
Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door. FWD watertight door striker plates and dogs were painted, unserviced, difficult and slow to close.
46 CFR 179.330(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: MI's witnessed op test of doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 May 2023
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck. Reach rod was not adequately secured and located behind ladder potentially interfering with personnel.
46 CFR 182.510(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: MI's verified reach rod was secured.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 May 2023
Resolved
Each vessel must - have permanent draft marks at each end of the vessel; or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel is missing these hull marks.
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 6 May 2025
Resolution: During DDX activity# 8032285 the USCGMI issued a worklist item for this same deficiency. During this same DDX the vessel installed draft marks, and the associated worklist item was cleared. The USCGMI should have cleared this deficiency as well.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2022
Resolved
All equipment, including switches, fuses, lamp holders, etc., must be suitable for the voltage and current utilized. Found deck lights are spliced into the navigation light conductor & circuit. Provide MSC approved plans for the installation of the deck lights. 46CFR183.220(a) 46CFR183.115(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2022
Resolved 8 June 2022
Resolution: Vessel received MSC approval for courtesy and navigational lights. Attended vessel see activity #7419369.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 April 2022
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Found the following sails - Flying Jib, Fore Top, and the Main Top with numerous repairs and they cannot be repaired any further. The vessel is restricted from using said sails without OCMI authorization. 46CFR176.840
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2022
Resolved 30 May 2023
Resolution: Witnessed operation of the following sails, flying jib, fore top, and the main top underway, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 April 2022
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Found sta lok turnbuckles not properly secured. 46CFR176.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 7 April 2022
Resolution: Placed stainless steel cotterpins in each sta lok turnbuckle.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 April 2022
Resolved
All machinery to be installed and maintained in such a manner as to afford adequate protection against machinery failure. Found packing gland leaking for the fire pump supply valve. Found union leaking in the fire pump supply piping. 46CFR182.01-5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 7 April 2022
Resolution: Tightened valve, no leakage after conducting test.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 April 2022
Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hose suitable for use in fire fighting. The hand portable fire pump may also serve as a bilge pump. Vessel does not have a portable fire/bilge pump on board. 46CFR181.10-5
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 7 April 2022
Resolution: Ordered new portable fire pump and witnessed its operability IAW 46CFR181.10-5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2022
Resolved
In systems and applications where flexible hoses are permitted to be clamped: double hose clamping is required where practicable. Vessel has an overboard discharge hose hanging & not connected to anything in compartment below galley. 46CFR182.410 (d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 7 April 2022
Resolution: Removed hose and placed a plug in through-hull fitting.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts of large enough scale to make safe navigation possible. Charts, Light Light, Colregs, and Coast Pilot are outdated. Light list, Colregs, and Coast Pilot were corrected on the spot, Charts remain outdated.46CFR185.20-35
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 7 April 2022
Resolution: Replaced charts with current corrected charts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 April 2022
Resolved
For each watertight door, an indicator must be installed in the pilot house and at each vessels operating station from which the door is not visible. The indicator must show whether the door is open or closed. Vessel's number 2 Class 1 WTD indicating switch was inoperable. 46CFR170.270 (e)
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: O/O replaced door alarm switch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 4 April 2022
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Vessel did not have a guard in place for the top engine. 46CFR177.35-10
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: O/O put guard on top engine before end of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2022
Resolved
An adult life jacket must be provided for each person carried don board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section. Vessel had 4 adult and 1 child PFD unserviceable. 46CFR180.71 (a)(b)
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: O/O replaced all 4 adult and 1 child PFD during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 April 2022
Resolved
Junction boxes, connection boxes, and outlet boxes, for use shall be watertight. Connection box needed cover in compartment under galley. 46CFR183.10-20(k)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: O/O placed cover over connection box.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 April 2022
Resolved
A vessel on an Oceans, Coastwise, Limited Coastwise, and Great Lakes routes must carry: Six hand red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including but not limited to, approval series, 160.121 and six hand orange smoke distress signals approved in subchapter Q in this chapter, or other standard specified by the Commandant. Vessel was missing six hand orange smoke distress signals. 46CFR180.68(a)
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: O/O received new package of 6 orange flares.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 December 2021
Resolved
Conduct underway rigging examination/survey in the presence of Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2022
Resolution: Witnessed setting and use of sails IAW vessel sail plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2020
Resolved
At each initial and subsequent inspection, the owner shall be prepared to have the vessel ready for inspections of hull structure and appurtenances, including superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Update vessel's current PMP to meet all requirments of NVIC 02-16.
(A) Provide a Rigging Preventative Maintenance Plan that provides a level of detail commensurate with Appendix (2), Enclosure (1) of NVIC 02-16(Rigging Inventory/Preventative Maintenance Inspection Template (Sample)) or propose a mutually acceptable third party to survey the rigging and provide a report with a level of detail commensurate with either Appendix (3) or (4) to Enclosure (1) of NVIC 02-16 (Third Party Rigging Survey Samples A & B).
Requirements to be satisfied not later than 01/31/2021.
Action required: 705 - Other - as specified
Due 31 January 2021
Resolved 5 February 2021
Resolution: Received vessel's PMP.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 December 2020
Resolved
At each initial and subsequent inspection, the owner shall be prepared to have the vessel ready for inspections of hull structure and appurtenances, including superstructure, masts, and similar arrangements constructed on the hull, and on a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel is not in compliance with NVIC 02-16.
(B) Step masts and make available for inspection. Take down rig and make available for inspection. Requirements to be satisfied not later than 12/31/2021.
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 8 April 2022
Resolution: Vessel completed rig inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 December 2018
Resolved
A vessel exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock and internal structural examination at least once every two years. (46 CFR 176.600(c)(1))
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2018
Resolved 4 December 2018
Resolution: Conducted credit drydock given this date.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
The vessel is currently broadcasting (1) Length Difference.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2018
Resolved 6 March 2019
Resolution: Owner reported AIS discrepancies corrected. Used NAVCEN to verify accuracy of vessel's AIS broadcast.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2018
Resolved
Found 3 of the required adult life jackets were found to be non-serviceable. Witnessed vessel owner destroy in the presence of [name withheld] total persons allowed to 131.
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 20 June 2018
Resolution: Vessel placed 3 new adult life jackets into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2018
Resolved
Bilge suction strainers were missing/rotted in the forepeak and galley spaces.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2018
Resolution: Vessel installed new bilge suction strainers. Witnessed operational bilge pump test taking suction from forepeak.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 June 2016
Resolved
Vessel needs to develop a written maintenance plan for their sail rigging equipment and components in accordance with NVIC 02-16.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 4 August 2016
Resolution: Rigging Log submitted, reviewed and accepted.