Records from 1980 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 87
13 April 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8344869
31 March 2026
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8338659
24 October 2025
Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8258311
13 January 2025
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8043572
22 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7916908
14 March 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7877928
13 December 2023
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7838560
12 December 2023
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7838059
19 October 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7810970
1 May 2023
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7678875
21 March 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7646441
19 January 2023
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7623741
18 October 2022
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7592556
1 June 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7530860
10 May 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7447826
7 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7392231
2 December 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7361407
28 October 2021
Drydock Exam · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7340011
20 August 2021
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7292214
14 June 2021
Excursion Permit · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7224862
19 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7176314
19 March 2021
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7180712
5 October 2020
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7071844
27 May 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6978040
23 February 2020
Examination of Repairs · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6914058
22 February 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6913654
21 January 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6888009
25 October 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6836535
24 April 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6666589
19 December 2018
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6597964
30 April 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6402236
13 November 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6305585
24 March 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6199092
24 March 2017
DAPI Audit · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6235935
2 March 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6090607
22 October 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6029545
10 May 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5874227
12 April 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5848997
21 March 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5837952
8 March 2016
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5829106
19 November 2015
Plan Review "T" Boat · Examination of Repairs · In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5774542
16 November 2015
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5762774
17 October 2014
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5013118
15 October 2014
Plan Review "T" Boat · Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5012898
11 July 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3264684
6 April 2006
COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2621287
3 April 2006
Hull Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2612098
19 July 2004
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2126084
11 February 2004
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2003788
17 July 2003
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1838490
10 July 2002
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1644251
8 November 2001
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075689
19 April 2001
COI Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1425109
22 September 2000
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1054600
23 August 2000
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1423433
27 March 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1446898
9 June 1999
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421703
4 February 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 792309
9 September 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 797889
10 April 1998
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1381192
16 April 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378010
29 May 1996
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1355817
12 April 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1430030
14 April 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857865
13 January 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162378
21 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 841548
15 April 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1158272
19 May 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013540
16 April 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960596
26 April 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1248105
8 January 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1232957
18 October 1990
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1224623
10 April 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1219558
27 April 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349949
23 March 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350764
9 May 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1040760
18 November 1987
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1308532
21 October 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017073
27 May 1987
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338759
7 May 1986
Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1298871
2 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 984314
1 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286864
11 May 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973110
11 May 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965530
30 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277514
2 October 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971205
14 May 1980
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274208
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 October 2025
Resolved
Provide hull thickness report of MI identified pitting of hull plating in STBD FWD void from keel to 3rd frame up.
Action required: 705 - Other - as specified
Resolved 30 October 2025
Resolution: Completed
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 24 October 2025
Resolved
Crop and renew Min 12" x 12" MI identified hole in fwd bulkhead of STBD steering gear room.
Action required: 705 - Other - as specified
Resolved 17 February 2026
Resolution: complete
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 24 October 2025
Resolved
Crop and renew Min 12" x 12" MI identified hole in fwd bulkhead of port steering gear room.
Action required: 705 - Other - as specified
Resolved 17 February 2026
Resolution: complete
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2025
Resolved
A catamaran vessel must be equipped with bilge pumps for each hull, as if each hull is a separate vessel, in accordance with Table 182.520(a), except where: One dedicated pump is located in each hull; each dedicated pump is driven by an independent source of power; and the bilge system is permanently cross connected between hulls. Fixed electric bilge pump in the port hull engine room was inoperable.
//46 CFR 182.520(j)//
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 January 2025
Resolved 13 January 2025
Resolution: Witnessed operation after the crew troubleshooting the pump.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 March 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel's paper and electronic charts were not up-to-date. 46 CFR 184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2024
Resolved 22 May 2024
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 13 December 2023
Resolved
33 CFR 159.95, Each MSD must be free of design defects that would allow toxic substances to escape to the interior of the vessel. Leak found coming from sewage valve on the bottom of the holding tank in the port MSD space.
Action required: 10 - Deficiency Rectified
Due 13 December 2023
Resolved 13 December 2023
Resolution: Replaced with new gate valve, no visible leaks present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2022
Resolved
A catamaran vessel must be equipped with bilge pumps for each hull, as if each hull is a separate vessel, in accordance with Table 182.520(a), except where: One dedicated pump is located in each hull;(2) Each dedicated pump is driven by an independent source of power; and (3) The bilge system is permanently cross connected. The port side catamaran bilge pump was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2022
Resolution: Bilge pump repaired and witnessed proper operation.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 February 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB battery expired FEB2020.
Action required: 705 - Other - as specified
Resolved 10 February 2022
Resolution: EPIRB battery replaced. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 February 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication. Nautical charts and publications were not up to date and current(2020.)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2022
Resolution: Charts and publications updated, witnessed via objective evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 February 2022
Resolved
Each life jacket must be marked with Type I retro-reflective material. Each life jacket must be marked with Type I retro-reflective material.05 children life jackets retro reflective tape was worn and need of replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 February 2022
Resolution: Life jackets had new retro put on. All sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 February 2022
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Parts of the emergency broadcast placard unreadable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 February 2022
Resolution: New emergency broadcast placard installed. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 February 2022
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter fire hose is required. Fire station missing spanner wrench.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2022
Resolution: Spanner wrench on board. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Waterlight for the ring buoy was not attached correctly.
Action required: 10 - Deficiency Rectified
Resolved 8 February 2022
Resolution: Tied water light to body of life buoy. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 February 2022
Resolved
Secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter. IBA's were not attached to the evessel correctly. The painter lines were attached directly to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 7 February 2022
Resolution: Tied painter to the weak link. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is certificated to carry 132 passengers but only has serviceable life jackets for 83 adults. Vessel will be limited to 83 adult passengers until serviceable life jackets are available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2021
Resolved 7 May 2021
Resolution: Inspector's attended vessel and verified 47 new lifejackets
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 23 February 2020
Resolved
Vessel damage to forward bulwark anchor pocket and four bridge windows, provide repair proposal.
46CFR 177.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2020
Resolved 5 May 2020
Resolution: Provided documentation for windows. Completed reparis to forward bulwark.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 February 2020
Resolved
Vessel bridge equipment damage by salt water, vessel must demonstrate proper operation to all electrical equipment/navigation equipment to attending OCMI
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2020
Resolved 5 May 2020
Resolution: Conducted test of electronic and electrical equipment on bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2020
Resolved
Child lifejackets shall be stored seperately or properly segregated from adult lifejackets. Child lifejackets not properly segregated from adult lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2021
Resolution: A divider was placed to segregate the child and adult life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2020
Resolved
Donning placards for each type of lifejackets carried on board shall be conspicuously posted. Donning placards were only provided for one of the two lifejacket types carried on board..
Action required: 10 - Deficiency Rectified
Resolved 28 October 2021
Resolution: Verifed donning placard was posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2019
Resolved
46 CFR 183.220
All electrical equipment and circuits must be clearly marked and identified. Circuit breaker panels in the pilot house and engine room contain incorrect labels which correspond to different breakers. Correct to the satisfaction of attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 7 May 2019
Resolution: Inspected the directories for all breaker panels onboard. Directories were updated and found to be accurate.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 July 2017
Resolved
When compared to available physical chemical testing records, the submitted 2016 MIS report was inaccurate.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 24 July 2017
Resolution: DER corrected errors and re-submitted MIS report to USCG.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 17 July 2017
Resolved
Seasonal crewmembers that were not currently working had not been removed from the current employee list provided to the consortium and used for the random testing pool.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 24 July 2017
Resolution: Corrected employee list.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 July 2017
Resolved
Rover Marine Inc has a drug and alcohol policy in place. However, there were no records or proof that crewmembers and supervisors received required EAP training.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 24 July 2017
Resolution: Provided proof of training.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 July 2017
Resolved
There were no records available for required previous employer DOT drug and alcohol records background checks prior to employees assuming safety sensitive positions. 49 CFR 40.25
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 24 July 2017
Resolution: DER provided proof of efforts made for previous DOT employers.
Engineering › Bilge Water Management System › Valve
Issued 12 April 2016
Resolved
reachrod in starboard forepeak is inoperable.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 10 May 2016
Resolution: reach rod in starboard forepeak is operable, the missing bolt and nut connecting rod to valve have been replaced in kind; all sat.
Electrical › Electric Supply System (service) › Cable
Issued 12 April 2016
Resolved
Dead end wires found on the Port Main Engine.
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 10 May 2016
Resolution: Dead end wires on the Port Main Engine have been removed; all sat
Lifesaving › Lifefloat › Markings
Issued 12 April 2016
Resolved
02 Lifefloats found inproperly marked, 01 lifefloat found with broken paddle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 10 May 2016
Resolution: Both Life floats have been properly marked and the broken paddles have been replaced in kind; all sat
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2016
Resolved
Electrical wires found not properly supported.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 10 May 2016
Resolution: Electrical wires have been proper supported, all sat.
Construction/Loadline › Hull › Weld
Issued 8 March 2016
Resolved
Vessel damaged by wave, intermittent cracked welds along forward bulwarks, anchor pocket, and on internal frames identified on the inspection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 21 March 2016
Resolution: All identified welds have been repaired to the satisfaction of attending CG Marine Inspector.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 11 February 2016
Resolved
Contact CG MI to inspect installation and witness testing of new load-shedding system, in accordance with the plans approved by the CG Marine Safety Center on 11 February 2016.
Condition: Invalid
Due 23 February 2016
Resolved 23 February 2016
Resolution: Attended the vessel with [name withheld] & vessel owner to conduct verification of electrical load-shedding system in accordance with approved plans; all sat. Inspected labeling of new electrical components and updated switchboard diagram; all sat.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 18 December 2015
Resolved
As currently configured, vessel's generator does not provide sufficient AC power for both normal operating & emergency systems concurrently. Submit plans for load-shedding relay system, as proposed to OCMI, to USCG Marine Safety Center for review. 46 CFR 183.200 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 22 December 2015
Resolution: Vessel owner submitted plans and proposal for load-shedding relay system to MSC Electrical Division.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 18 December 2015
Resolved
Submit edited emergency procedures to CG MI requiring the manual shut-down of the HVAC system prior to the energizing of any emergency system (i.e., fire or bilge pumps). 46 CFR 185.510
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2015
Resolved 19 December 2015
Resolution: Vessel owner provided new emergency procedures for the vessel, documenting the requirement to maually shut down the HVAC system prior to energizing the fire or bilge systems in case of an emergency.
Electrical › Electric Generation Source (service) › Generator
Issued 20 November 2015
Resolved
Provide documentation that service generator has been de-rated to %80 of the full load rating by a certified technician in accordance with manufactures instructions.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 25 November 2015
Resolution: [name withheld] verified generator de-rating documentation/proof provided by the vessel owner; all sat.
Electrical › Electric Generation Source (service) › Generator
Issued 20 November 2015
Resolved
Affix data plate to generator that includes the de-rated capacity's, IAW documentation provided by certified technician ref. CG835 item #1.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 25 November 2015
Resolution: [name withheld] inspected new generator data plate installation; all sat.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 20 November 2015
Resolved
Provide repair/install proposal for over-current device that dose not exceed 115% of the generators reduced load capacity.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 November 2015
Resolved 25 November 2015
Resolution: Inspected new over-current device installation - over-current protection is set to 100% of the generator's new (de-rated) maximum output of 50 amps; all sat.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 20 November 2015
Resolved
Provide attending MI results of new electrical load analysis for de-rated generator. Notify CG MI when electrician will attend vessel to complete analysis, for CG presence (discretion of MI)
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 December 2015
Resolved 8 December 2015
Resolution: Received new electrical load analysis completed by ABYC-certifified marine electrician, [name withheld]; all sat.
Electrical › Electric Supply System (service) › Cable
Issued 11 February 2004
Resolved
REMOVE DEAD ENDED SERVING TRANSDUCER IN #2 COMPT STBD SIDE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2004
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 11 February 2004
Resolved
RENEW FLAME SCREENS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2004
Construction/Loadline › Hull › Weld
Issued 11 February 2004
Resolved
GOUGE AND REWELD ALL WELDS AS FOUND IN #1 COMPT P & S SIDES.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 17 July 2003
Resolved
RENEW BROKEN WINDOW IN PILOT HOUSE. LEGACY COMPONENT DESC: SAFETY GLASS
Due 17 August 2003
Resolved 17 July 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 17 July 2003
Resolved
PROVIDE 1 ADDITIONAL B-II EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 18 July 2003
Resolved 17 July 2003
Documentation
Issued 19 April 2001
Resolved
SHOW COMPLIANCE WITH CG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 26 April 2001
Resolved 9 May 2001
Electrical
Issued 19 April 2001
Resolved
REPAIR WIRING SERVING GRIDDLE WHICH HAS PULLED OUT OF STRAIN RELIEF DEVICE WHERE WIRING ENTERS BREAKER BOX.
Condition: Unknown
Due 26 April 2001
Resolved 20 April 2001
Documentation
Issued 19 April 2001
Resolved
SHOW PROOF OF LOGGED TRAINING AND DRILLS.
Condition: Unknown
Due 26 April 2001
Resolved 20 April 2001
Lifesaving
Issued 19 April 2001
Resolved
SHOW PROOF OF LOGGED MONTHLY EPIRB TESTS.
Condition: Unknown
Due 26 April 2001
Resolved 20 April 2001
Lifesaving
Issued 19 April 2001
Resolved
RENEW 1 FLOATING WATERLIGHT WHICH IS MISSING PARTS. NO NIGHT OPS UNTIL CLEARED.
Condition: Unknown
Due 26 April 2001
Resolved 20 April 2001
Unknown
Issued 4 February 1999
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Lifesaving
Issued 10 April 1998
Resolved
Prior to carrying passengers, ensure that proper drills are conducted in man-overboard, fire, and abandon ship. Log entries documenting the trainingshall be completed.
Condition: Unknown
Due 10 April 1998
Resolved 10 April 1998
Documentation
Issued 10 April 1998
Resolved
Ensure that the cognizant OCMI is immediately notified of vessel's arrival if and when vessel is sold and is transferred from the MSO Mobile zone.
Condition: Unknown
Due 10 April 1999
Resolved 19 April 1998
Lifesaving
Issued 16 April 1992
Resolved
THREE OF THE FIVE LIFE FLOATS LIFE LINES MUST FASTEN AROUND THE OUTSIDE OF THE FLOAT IN BIGHTS NO LONGER THAN 1M (3FT).
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Lifesaving
Issued 16 April 1992
Resolved
RENEW PLYWOOD PLATFORM TO AFT PORT 15 MAN LIFE FLOAT.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Navigation
Issued 16 April 1992
Resolved
REPAIR ANCHOR LIGHT POLE MOUNT TO ENSURE PROPER POSITIONING.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992
Resolved
IDENTIFY AND LABEL ALL MOTOR CONTROLLERS AND ELECTRICAL DISTRIBUTION PANELS.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992
Resolved
RENEW FLEXIBLE HOSES FOR FUEL OIL SYSTEM THAT EXCEED 30" IN LENGTH IN PORT ENGINE ROOM AND PORT FUEL TANK COMPARTMENT.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992
Resolved
RENEW FLAME SCREEN TO BOTH P/S FORWARD FUEL TANK VENTS.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992
Resolved
PROVE OPERATION OF REMOTE REACH RODS TO FORWARD FUEL TANK SHUTOFF VALVES.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Documentation
Issued 16 April 1992
Resolved
INSTALL OIL POLLUTION PLACARDS AT EACH BILGE MANIFOLD.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Lifesaving
Issued 16 April 1992
Resolved
RENEW LIFE FLOAT PLATFORM NETTING TO MEET REQUIREMENTS SET FORTH IN 46 CFR 160.027. _x001C_
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Accommodation/Occupational Safety
Issued 16 April 1992
Resolved
INSTALL GUARD TO MENS BATHROOM EXHAUST FAN.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Accommodation/Occupational Safety
Issued 16 April 1992
Resolved
REPAIR OR REPLACE WATER FAUCET IN MENS BATHROOM.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992
Resolved
REPAIR OR REPLACE BATTERY DISCONNECT SWITCH IN PORT ENGINEROOM 32VDC BATTERY BANK.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992
Resolved
CLEAN BATTERY TERMINALS ON 8VDC BATTERY BANK IN PORT ENGINEROOM.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992
Resolved
REMOVE ALL PET COCKS FROM FUEL FILTERS AND INSTALL PIPE PLUGS.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Accommodation/Occupational Safety
Issued 16 April 1992
Resolved
SECURE FRESH WATER PUMP TO ITS MOUNT.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Navigation
Issued 16 April 1992
Resolved
RENEW GALVANIZED PIPING FFROM HYDRAULIC SYSTEM IN STEERING COMPARTMENT AND REPAIR LEAKS.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Accommodation/Occupational Safety
Issued 16 April 1992
Resolved
INSTALL INSECT SCREEN TO FRESH WATER VENT ON PORT SIDE MAIN DECK.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Unknown
Issued 27 April 1989
Resolved
CLEAN ELECTRIC VENTS IN BOTH HEADS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
PROVIDE SUITABLE COVER FOR GALLEY VENT FAN.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
PROVE PROPER OPERATION OF BOTH FOSO REMOTE VALVES.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
PROVIDE PROPER FOOT STRAINERS FOR, AND PROVE PROPER OPERATION OF ALL 8 FIXED BILGE PIPING HEADS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
PROVE PROPER OPERATION OF, OR REMOVE BOTH E.R. POWER VENTILATORS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
PROVE PROPER OPERATION OF OR REMOVE SSB RADIO.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Unknown
Issued 27 April 1989
Resolved
MARK 32U EMERGENCY LIGHT SWITCH.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989