Records from 1988 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 64
15 June 2026
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8401265
6 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8343562
16 January 2026
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8297330
16 July 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7944429
16 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7825482
31 October 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7818818
11 October 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7806789
4 October 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7571506
14 October 2021
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7327510
15 July 2021
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7256161
17 September 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7058519
2 April 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6934435
4 November 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6848412
4 November 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6858566
21 October 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6835386
17 October 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6555466
30 October 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6295371
30 October 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6310226
17 October 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6286547
24 March 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6199092
18 July 2016
COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5945116
4 November 2015
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5752416
15 October 2015
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5741827
28 September 2015
Drydock Extension
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5730267
22 October 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5034065
8 October 2014
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5001705
27 September 2011
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4150608
20 July 2011
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4071749
22 November 2010
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3897091
2 November 2010
Annual Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3865402
24 December 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3384599
17 December 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3381494
17 November 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3364843
4 November 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3356382
12 October 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3015216
21 September 2007
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3015227
4 August 2006
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2725347
5 October 2005
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2507371
26 September 2005
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2499370
17 September 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2197240
7 August 2003
Annual Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1868614
9 August 2002
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1657211
10 August 2001
COI Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422105
22 August 2000
Plan Review "T" Boat
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1361752
19 April 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452663
9 September 1999
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1119099
19 July 1999
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1369279
10 July 1998
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1383901
11 May 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1430553
24 July 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1439904
25 July 1996
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1359223
18 March 1996
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1411247
19 July 1995
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1438336
25 May 1994
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1400024
30 March 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1435463
28 June 1993
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 844064
26 May 1993
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 832993
11 May 1992
COI Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1263459
8 April 1992
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 946195
16 May 1991
Re-Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928584
4 April 1991
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 904557
13 June 1990
Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1222828
23 May 1989
Plan Review "T" Boat · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 894465
15 September 1988
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 892405
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 June 2026
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b). Vessel is missing one 2-A portable fire extinguisher in the forward compartment. Provide portable fire extinguisher for the forward compartment prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2026
Resolved 18 June 2026
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 June 2026
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel’s safety radio certificate is expired, renew safety radio certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 26 June 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2026
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the
duties and functions of a position, required by the vessel’s Certificate of Inspection. Provide copy of updated Maritime Consortium Certificate of Compliance listing all employees that work or may work on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 18 June 2026
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 June 2026
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a marine radio operators permit issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Provide copy of all vessel operators marine radio operators permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 18 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 June 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel did not have current charts, provide current charts on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 10 July 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 June 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Aspirin and burn gell expired in first aid kit, provide new.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 18 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2026
Resolved
A vessel not required to have a power driven fire pump must have at least three (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. One fire bucket is missing a line, provide a line on the fire bucket.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2026
Resolved 18 June 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 January 2026
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessels anniversary date is 15 July. No annual inspection was conducted in 2025. COI is invalid. Conduct annual inspection prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2026
Resolved 15 June 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 January 2026
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is overdue for its drydock inspection. Vessel's drydock inspection was due 31Dec2025. COI is invalid. Conduct a credit drydock inspection prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 January 2026
Resolved 6 April 2026
Resolution: Completed credit drydock and internal structural exam.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 July 2024
Resolved
A vessel on a lakes, bays and sounds route must carry:
Three hand red flare distress signals and three hand orange smoke signals, in accordance with 160.021 & 160.037 in subchapter Q. A hand red flare distress signal can be substituted for any of the orange smoke distress signals. Vessel had 3 expired smoke flares on board and needs to replace them.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has child life jackets, but no donning placard for the type and brand of life jacket. Post placard as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2024
Resolved 18 July 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years; Vessel is overdue for drydock inspection. Complete drydock inspection prior to the carriage of passengers. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2023
Resolved 15 November 2023
Resolution: Vessel entered dry dock, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 11 October 2023
Resolved
Each survival craft required on a vessel by this part must meet one of the following:
for a life float - approved under approval; series 160.027 or other standard approved by the commandant, and must be in good and serviceable condition. MI observed defects on 03 locations on the Life Float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2023
Resolved 20 December 2023
Resolution: Life float repaired at dry dock
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 November 2019
Resolved
Renew to original wood starboard side in compartment 3. Submit repair proposal to CG Marine Inspectors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 November 2019
Resolved
Repair cracks along starboard side hull below waterline. Submit repair proposal to CG Marine Inspectors.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 4 November 2019
Resolved
Renew forward port side thru-hull fitting sealant.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 November 2019
Resolved
Renew coaming to original wood in steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 October 2019
Resolved
Vessel's lifelfoat shows deterioation and tears at the seams. Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. Repair of replace lifefloat in accordance with manufacturer's instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 4 November 2019
Resolution: Repaired tears at the seams with repair kit.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 October 2019
Resolved
Vessel's charts have not been updated since 2009. Vessels are required to carry adequate and up-to-date charts. Replace or udpate charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 22 November 2019
Resolution: Vessel has updated charts
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 October 2019
Resolved
The current generator installed is rated for 40'C ambient temperature. Generators and motors designed for 40'C may be used in 50'C ambient locations, provided the machines are de-rated to 80% of the full load rating and the rating or setting of the overcurrent devices are reduced accordingly. An additional nameplate specifying the de-rated capacity shall be provided for each such motor and generator. De-rate generator to 80% of the full load rating and reduce the setting of the overcurrent devices accordingly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2020
Resolved 2 April 2020
Resolution: Generator has been de-rated to 80% full load rating.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 October 2017
Resolved
Vessel didn't have all items required for first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 October 2017
Resolution: Vessel purchase Coast Guard approved first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 17 October 2017
Resolved
Operating Charts outdated
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 October 2017
Resolution: Vessel provided current navigational charts.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 17 October 2017
Resolved
Unable to secure ventilation for fixed firefighting in the engine space
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 30 October 2017
Resolution: Vessel replaced rotten wood to repair the engine room ventilation. Repairs allowed for ventilation to be properly secured to the engine space.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 November 2015
Resolved
Two Kapok type life jackets had compromised bouncy chambers.
Action required: 705 - Other - as specified
Resolved 5 November 2015
Resolution: Corrected on the spot. Both life vest were destroyed in the presence of [name withheld] remaining life vest to satisfy COI requirements.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2014
Resolved
Vessel had expired medication in first aid kit. Vessel must replace expired medication.
Due 3 November 2014
Resolved 20 October 2014
Resolution: Vessel replaced expired medication in first aid kit.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 October 2014
Resolved
Vessel is required to have 22 adult lifejackets marked properly with retroreflective tape. Vessel has 9 adult lifejackets with suitable retroreflective tape. Vessel must replace retroreflective tape on 13 adult lifejackets. Vessel is restricted to a total of 9 adults.
Due 3 November 2014
Resolved 20 October 2014
Resolution: Vessel replaced retroreflective tape on 13 adult lifejackets. Vessel is no longer restricted to 9 adults.
Engineering › Bilge Water Management System › Valve
Issued 2 November 2010
Resolved
Electric sub bilge pumps do not have positive shut off valves at the hull. Provide shut off valves a the hull for all bilge discharges IAW 46 CFR 182.520(e)(7) within 30 days.
Condition: Design Flaw
Due 2 December 2010
Resolved 22 November 2010
Resolution: Installed postive shut off valves at the hull for all bilge discharges.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 November 2010
Resolved
Engine override from the fixed fire fighting system is not connected to generator. Ensure override/engine shutdown is connected to generator. Ensure override/engine shutdown is connected to generator IAW 46 CFR 181.420 (a)(3) within 30 days.
Condition: Improper Installation
Due 2 December 2010
Resolved 22 November 2010
Resolution: Engine overrde from the fixed fire fighting system was connected to the generator IAW 46 CFR 181.420 (a)(3).
Lifesaving › Lifefloat › Painter
Issued 2 November 2010
Resolved
Painter line to life float is decayed. Replace line IAW 46 CFR 180.175(f)(3) prior to carrying passengers more than one mile from shore.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2010
Resolution: Painter line replaced on life float.
Documentation › Certificates/Documents › FCC SSL
Issued 4 November 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 24 December 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 4 November 2008
Resolved
Provide 2 additional adult life preservers IAW 46 CFR 180.71. Vessel capacity reduced to 31 persons until cleared.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 17 December 2008
Resolution: Provided 2 additional adult life preservers.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 November 2008
Resolved
Properly stow child life preservers separately from adult life preservers with appropriate labeling IAW 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 4 December 2008
Resolved 17 December 2008
Resolution: Separated child life preservers from adult life preservers and provided appropriate labeling.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 4 November 2008
Resolved
Provide proof of hydrostatic testing of portable fire extinguishers IAW 46 CFR 181.500 prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2008
Resolution: Provided proof of new portable fire extinguishers.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 November 2008
Resolved
Conduct satisfactory drills with full manning to the satisfaction of the attending marine inspector prior to operating with passengers IAW 46 CFR 185.524.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2009
Resolution: Conducted satisfactory fire and man overboard drills with full manning.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 4 November 2008
Resolved
Provide proof of fixed fire fighting certificate IAW 46 CFR 176.810(b)(2) prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2008
Resolution: Provided proof of fixed fire extinguishing certificate.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 October 2005
Resolved
Both ring buoy's do not have required amount of type I Retro reflective material as required by 46 CFR 185.604(i). Master is to add required amount of 31 square inches to each side of both ring buoy's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Owner placed adequate amount of type I Retro reflective material to both life buoy’s to satisfaction of attending Coast Guard Marine Inspector.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 October 2005
Resolved
Stencil two life jackets as required with vessel's name.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Owner stenciled two required life jacket with vessel''s name to satisfaction of attending Coast Guard Marine Inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 5 October 2005
Resolved
Provide proof of FCC Safety Certificate as required by 47 CFR 80.903 with in 30 days.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Owner provided proof of FCC Safety Certificate to satisfaction of attending Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 October 2005
Resolved
Repair/replace magnetic compass.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Owner replaced magnetic compass. Compass tested for operation to satisfaction of attending Coast Guard Marine Inspector.
Documentation › Logs/Records › Drug Test Records
Issued 5 October 2005
Resolved
Provide proof that master and deckhand are on a random drug testing program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Owner provided proof of Master and deckhand are on a random drug testing program to satisfaction of attending Coast Guard Marine Inspector.
Engineering › Diesel Engine (propulsion-electric) › Pump, Positive Displacement
Issued 5 October 2005
Resolved
Repair/Replace leaking water pump seal on electrical generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Owner replaced leaking water pump. Tested operation of pump to satisfaction of attending Coast Guard Marine Inspector
Engineering › Bilge Water Management System › Not Operational
Issued 17 September 2004
Resolved
Repair bilge high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2004
Resolution: Repaired broken wire to bilge high level alarm. Alarm tested satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 September 2004
Resolved
Replace three missing lifejackets. Limited to 30 persons on board until lifejackets are replaced.
Due 17 September 2004
Resolved 17 September 2004
Resolution: Installed three lifejackets.
Construction/Loadline › Hull
Issued 9 August 2002
Resolved
Prior to carriage of passengers, conduct credit drydock examination.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2003
Resolved 7 August 2003
Operations/Management › Drills/Instruction
Issued 9 August 2002
Resolved
Prior to carriage of passengers, conduct fire and man overboard drills to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2003
Resolved 5 September 2003
Fire Fighting
Issued 10 August 2001
Resolved
INSTALL MANUAL PULL BOX FOR FIXED CO2 SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 19 July 1999
Resolved
MOUNT LIFEJACKET DONNING PLACARD AND EMERGENCY INSTRUCTIONS ON BULKHEAD PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Documentation
Issued 19 July 1999
Resolved
PROVIDE TRAINING LOGBOOK AND BRIDGE LOGBOOK PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Documentation
Issued 19 July 1999
Resolved
PROVIDE PROOF OF USCG APPROVED DRUG TESTING PROGRAM FOR ALL EMPLOYEES PRIORTO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Navigation
Issued 19 July 1999
Resolved
PROVIDE CURRENT TIDES & CURRENT TABLE FOR HAMPTON ROADS AREA.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Lifesaving
Issued 19 July 1999
Resolved
PROVIDE 3 HAND RED FLARES AND 3 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 28 July 1999
Resolved 27 July 1999
Documentation
Issued 19 July 1999
Resolved
PROVIDE CURRENT OPERATOR'S LICENSE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Documentation
Issued 26 May 1993
Resolved
OBTAIN AND PROVIDE EVIDENCE OF HAVING A VALID FCC RADIOTELEPHONY CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 May 1993
Resolved 26 May 1993
Construction/Loadline
Issued 11 May 1992
Resolved
PROVIDE MEANS OF DEWATERING FORE PEAK COMPARTMENT, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Construction/Loadline
Issued 11 May 1992
Resolved
PROVIDE MEANS OF DEWATERING CENTER COMPARTMENT BY WAY OF AN INSTALLED BILGEPUMP(S) PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Documentation
Issued 11 May 1992
Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN THE RANDOM DRUG TESTING PROGRAM FOR ALL CREWMEMBERS.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Engineering
Issued 4 April 1991
Resolved
PROVIDE 1 EA NEW FLAME SCREEN FUEL TANK VENT EACH SIDE.
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991