Records from 2001 to 2024. Most recent: inspection, 5 March 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE S/Y · MADISONVILLE, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Net Ton
1619 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 34
5 March 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7875687
12 September 2023
Periodic Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7790519
14 May 2023
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7799253
17 June 2021
Drydock Exam · Examination of Repairs · COI Inspection · Internal Structural Exam · Cargo Tank Internal · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7213013
9 July 2020
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7000974
12 July 2019
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6747224
16 July 2018
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6481499
10 August 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6229299
2 May 2016
MTSA Verification · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5861977
5 August 2015
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5207611
25 July 2014
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4933218
4 June 2013
MTSA/ISPS Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4610747
19 June 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4349507
12 July 2011
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4079377
12 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4132880
10 May 2010
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3740506
14 May 2009
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3470430
5 June 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3227921
4 February 2008
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3141820
30 January 2008
Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3139313
30 January 2008
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3139561
5 June 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2945116
13 March 2006
COI Inspection · Internal Structural Exam · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2599970
30 June 2005
Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2408995
26 April 2005
MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2343158
11 January 2005
Spot Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2274670
19 August 2004
Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2167649
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979022
11 July 2003
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1842932
22 July 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1655049
18 July 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1656947
16 April 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1607636
30 May 2001
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070513
24 May 2001
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373505
Construction/Loadline › Hull › Weld
Issued 30 January 2008
Resolved
(Prior to Loading Cargo) Vessel to make starboard quarter void of T/B FMT-3058 "Safe for Entry" so the cognizant OCMI may further inspect internal spaces for possible damage. Noted several areas where welds may have cracked. Could not positively determine if cracks were to coating or welds as the space was not "Safe for Entry".
Action required: 705 - Other - as specified
Resolved 14 May 2009
Resolution: The deficiency was outstanding for over a year without the crew noticing any problems. As no interest has been expressed by the issuers of the deficiency, it is being cleared by looking inside the voids without entering the space.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 30 June 2005
Resolved
Prove proper operation of cargo pump engine shut-down.
Condition: Unknown
Due 30 June 2005
Resolved 30 June 2005
Resolution: Corrected on the spot.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 11 January 2005
Resolved
Crossover hose was not properly marked.
Due 10 February 2005
Resolved 30 June 2005
Resolution: Found correct
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 11 January 2005
Resolved
Scupper plugs not closed properly. This was corrected on the spot.
Action required: 705 - Other - as specified
Resolved 11 January 2005
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 18 July 2002
Resolved
Complete operatoinal test of alarm system for vapor control system in the presenc of attending USCG Marine Inspector no later than 18 Aug 02.
Due 18 August 2002
Resolved 30 July 2002
Resolution: Test of alarm system witnessed by MSO New Orleans. Test satisfactory.