Documentation record
Registered dimensions (L × B × D)85.8 ft × 32.0 ft × 10.0 ft
Registered tonnagegross 260 / net 177
ITC dimensions (L × B × D)85.8 ft × 32.0 ft × 10.0 ft
ITC tonnagegross 341 / net 102
BuilderEASTERN SHIPBUILDING GROUP, INC · PANAMA CITY, FL, UNITED STATES · built 2006
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOUISVILLE, KY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it260 - Regulatory (Subpart C or D), Gross Ton
341 - Convention (Subpart B), Gross Ton
177 - Regulatory (Subpart C or D), Net Ton
102 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 43 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 27 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 43
22 June 2026
COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8410233
13 May 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8371034
8 September 2025
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8213135
26 August 2024
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7975586
12 July 2024
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7956644
22 March 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7882926
30 November 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7838978
31 August 2023
COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7780348
14 May 2023
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7799253
8 June 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7472223
15 July 2021
In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7257152
25 June 2021
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7235595
21 May 2021
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7207114
26 September 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7065600
6 February 2020
Type not recorded
No type recorded · USCGC MAKO (WPB 87303) · USCG East District (CGD-E) · Activity 6910212
24 January 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5059151
30 January 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4525519
23 August 2012
DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4434036
13 July 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4377832
10 January 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4226200
17 December 2011
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4210038
17 December 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4380862
21 September 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4151529
12 July 2011
Marine Casualty Follow Up
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4081238
12 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4082786
12 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4132880
25 August 2010
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3840618
24 July 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3808094
6 January 2009
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3389576
2 August 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368379
15 February 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3219413
15 January 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3130996
11 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3054912
10 September 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3055314
31 August 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3043984
1 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2984106
30 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2831266
27 September 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2789890
31 July 2006
MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2731759
13 July 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2711321
12 July 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2711638
6 June 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2672121
3 April 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2615297
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2023
Resolved
PV must have the MAWP indicated by stamp, nameplate, or other means visible to the crew. Stenciled markings indicated MAWP of 150PSI, while manufacture plate and relief valve indicate 200PSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2024
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 31 August 2023
Resolved
The pilothouse alerter system's secondary alarm was not alarming in the Captain's stateroom.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 August 2023
Resolved
If a dedicated storage cabinet for flammable and combustible products is provided it must be secured to the vessel so that it does not move. The storage locker on the 01-deck starboard side was not secured to the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2024
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 31 August 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. There was no emergency lighting in any of the crew sleeping quaters.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2023
Resolved
The life ring on the 01 deck starboard side has worn retro. Replace retro or ring buoy to bring back into a serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 January 2024
Engineering › Steering Gear System › Rudder
Issued 11 September 2007
Resolved
Rudder is locked into place hard over; unable to properly steer vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 August 2010
Resolution: Operational Test sat.