Records from 2001 to 2025. Most recent: inspection, 21 November 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Gross Ton
1619 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
21 November 2025
Examination of Repairs · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8264836
10 March 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8091055
24 April 2023
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7670859
16 March 2023
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7671807
12 January 2021
Cargo Tank Internal · Examination of Repairs · Drydock Exam · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7123559
4 May 2020
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6947819
29 May 2019
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6698137
28 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6706406
6 June 2018
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6436060
8 December 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6322235
9 June 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6168782
15 December 2016
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6131612
10 March 2016
MTSA Verification · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5826161
21 January 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5833612
12 May 2015
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5124910
28 September 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5001364
10 June 2014
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4884179
23 July 2013
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4658208
27 June 2013
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4632135
5 June 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4333590
25 February 2011
Internal Structural Exam · Drydock Exam · MTSA Verification · COI Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3945029
24 July 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3808094
10 December 2009
Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3645990
9 January 2009
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391341
14 May 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3204844
23 January 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3139758
18 May 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2933237
24 February 2006
Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2589197
17 December 2004
Annual Inspection · MTSA Verification
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2260701
17 May 2004
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2070520
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978966
22 January 2003
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1733755
19 October 2002
Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1698907
15 May 2002
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1617147
2 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 486554
23 March 2001
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1059847
22 February 2001
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1459667
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 June 2019
Resolved
Armored cable supplying #2 P/S and #3 P/S overfill alarms have excessive wear and do not meet regulation. Explosion proof box does not house cable in a secure way to eliminate vapor migration into the explosion proof box. Cargo vapor is escaping through fittings on the high-level alarm.
Ensure cable and explosion proof box both comply with standards outlined in 46 CFR 39.2009. Prior to loading cargo, prove compliance and proper operation of each high level alarm to attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2019
Resolution: USCG Inspector received satisfactory tech report and photos of repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 June 2019
Resolved
Cargo pump prime mover does not shut down when emergency shutdown is activated. Prior to loading cargo, prove proper operation of emergency shutdown to attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2019
Resolution: Determined to be caused by rusty/dirty pullies. Once pullies were cleaned, shutdown worked properly.
Construction/Loadline › Hull › Side Shell
Issued 27 June 2013
Resolved
Approximate inset of six feet long by five inches tall on the stbd side deck knuckle aft of the tank top - crop and renew.
Action required: 705 - Other - as specified
Due 27 July 2013
Resolved 23 July 2013
Resolution: Witness satisfactory air test of 5'' x 3'' insert; no discrepancies noted.
Deck/Cargo › Towing › Chocks
Issued 27 June 2013
Resolved
Port stern bitt is broken in half and needs to be replaced.
Action required: 705 - Other - as specified
Due 27 July 2013
Resolved 23 July 2013
Resolution: Inspected sastisfactory replacement of bit
Deck/Cargo
Issued 22 February 2001
Resolved
Complete 2 PSI vapor tightness test in the presence of CG Inspector to satisfaction of the cognizant OCMI before vessel loads or carries any cargoes.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001