MAURY USCG vessel records Sign in
← All vessels

FMT 3076

FMT 3076 is a 2001 tank barge. The Coast Guard has recorded 30 inspections since 2001, most recently in March 2026, along with 20 deficiencies and 1 casualty investigation in 2002.

Records from 2001 to 2026. Most recent: inspection, 19 March 2026.

Built
2001
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-36951

Inspections, by type

…with no type recorded3
Years with a record 19 calendar years (2001–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · MADISONVILLE, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Gross Ton
1619 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 10

Inspection history · 30

19 March 2026 Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · Drydock Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8323829
29 March 2023 Periodic Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7659302
14 January 2021 Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7115607
24 February 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6914443
19 February 2019 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6632703
12 February 2018 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6351787
9 February 2017 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6084814
19 January 2017 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6072217
8 April 2015 Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5098777
6 March 2015 Drydock Exam · Examination of Repairs · Internal Structural Exam · Cargo Tank Internal · Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5760849
21 January 2015 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5056768
28 May 2014 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4828844
31 May 2012 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4329861
17 May 2012 MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4313737
17 December 2009 Periodic Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3651217
16 March 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3431574
5 May 2008 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3207480
17 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2909205
6 February 2006 MTSA Verification · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2579871
4 November 2005 Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2527503
21 December 2004 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2262909
19 November 2004 MTSA Verification · Periodic Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2244502
4 February 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2000195
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979039
1 August 2003 Damage Survey · Examination of Repairs
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1863608
30 July 2003 Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1861987
30 July 2003 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1862436
19 October 2002 Type not recorded
No type recorded · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1698907
27 August 2002 Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1667263
21 November 2001 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1376823

Deficiency record · 20

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 April 2023 Resolved
THE INSPECTION SHALL BE SUCH AS TO INSURE THAT THE ARRANGEMENTS, MATERIAL, AND SCANTLINGS OF THE STRUCTURE FULLY COMPLY WITH THE APPLICABLE REGULATIONS FOR SUCH VESSEL AND ARE IN ACCORDANCE WITH APPROVED PLANS. PORT SIDE, AFT TIMBERHEAD SHEERED FROM ITS FOUNDATION. 2-4" HOLE EXISTS IN THE OUTER CORNER FROM THE BASE OF THE TIMBERHEAD FOUNDATION ON THE MAIN DECK, COMPROMISING WATERTIGHT INTEGRITY OF THE SPACE BELOW. VESSEL IS RESTRICTED FROM CARGO OPERATIONS. TRANSIT VESSEL TO NEAREST REPAIR FACILITY AT WEPFER MARINE. CUT-OUT EXISTING TIMBERHEAD FOUNDATION AND RENEW IN KIND. MARINE INSPECTORS SHALL WITNESS FIT-UP, FINAL REPAIR AND NON-DESTRUCTIVE TESTING PRIOR TO RESUMING NORMAL OPERATIONS.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2023
Resolution: 18 x 18 insert on deck. MI's witnessed NDT.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 28 February 2020 Resolved
Emergency shutdown for cargo pump engine didn't work on first attempt.
Action required: 10 - Deficiency Rectified
Resolved 28 February 2020
Resolution: The vessel represetative conducted maintenance on the damper closure device and the shutdown operated satisfactory prior to inspector's departure.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 February 2018 Resolved
Battery for Mast Head Light not instrincially safe and located in hazardous location on the weatherdeck.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 12 February 2018
Resolution: Mast Head light moved out of hazardous location to the satisfaction of attending Marine Inspector.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 12 February 2018 Resolved
Emergency shutdown did not perform as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 12 February 2018
Resolution: Witnessed proper operation of emergency shutdown on cargo prime mover to the satisfaction of attending Marine Inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 12 February 2018 Resolved
Hose not marked IAW 33CFR154.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 February 2018
Resolved 12 February 2018
Resolution: Cargo transfer hose marked correctly to the satisfaction of attending Marine Inspector.
Construction/Loadline › Structures › Cofferdam
Issued 19 January 2017 Resolved
During Annual inspection, attending CGMI noted damage to main structural members in the #4 and #5 STBD wing voids. Make wing voids gas free and available for inspection by CGMI. No repairs shall be made without knowledge of [name withheld] repairs to all affected structural members shall be to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 9 February 2017
Resolution: Vessel repaired damage to floor frames, inspected installation and welds. All sat.
Engineering › Fuel Oil Service System › Hose
Issued 19 January 2017 Resolved
Fuel line on cargo pump engine was chaffed through the jacketing. Replace fuel line with approved hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 19 January 2017
Resolution: Vsl rep replaced hose prior to MI leaving barge. All sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 January 2017 Resolved
While testing the remote pulls for the cargo pump engine, the vsl rep was unable to shutdown the cargo pump. The mechanism on the engine was frozen/rusted in place and would not shut the air supply. Make repairs and prove proper operation of the remote shutdown.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 19 January 2017
Resolution: Vsl rep was able to work the mechanism and get it unfrozen. Witnessed sat test of remote pull prior to departure from barge.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 7 December 2015 Resolved
Vapor connection flange face must have .5"X 1" stud on both flanges
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2015
Resolved 7 December 2015
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 7 December 2015 Resolved
Cargo alarm connection box door is broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 7 December 2015
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 8 April 2015 Resolved
Both port and starboard side containment for cargo piping manifolds needed to be drained of water/product mixture.
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: The containment was drained/pumped into the vessel''s slop tanks.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 April 2015 Resolved
The starboard side navigation light box/screen needed to be re-painted (flat black).
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: The box/screen was re-painted.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 8 April 2015 Resolved
The gauge on the vapor control piping was filled half-way with fluid that included dark brown spots in it.
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: The gauge was replaced in kind.
Construction/Loadline › Structures › Manhole
Issued 8 April 2015 Resolved
A dog to a port-side void space hatch cover was broken (going from the bow to the stern of the vessel, this was on the seventh hatch going to the aft/stern).
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: The dog was replaced in kind.
Construction/Loadline › Penetrations › Valve Flange
Issued 8 April 2015 Resolved
Air leaks could be heard from the internal cargo tank valve stems on the tops of the #3P, #3S and #1S cargo tanks.
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: Connection points on the valve flanges were tightened.
Communications › Visual Communication › Red Warning Signal
Issued 8 April 2015 Resolved
"Danger - Keep Out" needed to be re-painted on all of the cargo tank access hatch covers.
Action required: 705 - Other - as specified
Resolved 8 April 2015
Resolution: All cargo tank access hatch covers were re-painted with "Danger - Keep Out".
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 18 May 2012 Resolved
Re-test high level/overfill alarms with working box.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 31 May 2012
Resolution: Re-test of alarms satisfactory.
Stability › Watertight Integrity › General
Issued 18 May 2012 Resolved
Gaskets on all void hatch covers are corroded, allowing water to enter voids. Replace all gaskets
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 31 May 2012
Resolution: All gaskets satisfactorily replaced.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 19 November 2004 Resolved
Vapor Contorl System flange was missing flange stud.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2004
Resolution: Installed new stud
Construction/Loadline › Hull
Issued 30 July 2003 Resolved
Prior to carrying cargo- Present barge in a "Safe for Workers" environment for further inspection to damage sustained from a bridge allision this date. Apparent damage sustained IWO port bow corner wrapper. Be prepared to make permanent repairs to the satisfaction of the attending CG Inspector. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Resolved 1 August 2003
Resolution: Rewelded stiffiners.

Casualty record · 1

19 October 2002Routine · role: Involved in a Marine Casualty · activity 1698907
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.