Records from 2001 to 2024. Most recent: inspection, 3 July 2024.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · MADISONVILLE, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Regulatory (Subpart C or D), Net Ton
1619 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
3 July 2024
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7946661
16 December 2022
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7610025
16 December 2022
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7612072
10 February 2022
MTSA Verification · Examination of Repairs · Drydock Exam · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7386145
10 November 2020
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7093013
15 October 2020
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7062979
18 August 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7037484
13 August 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7032892
15 November 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6850168
27 November 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6600162
8 September 2017
Examination of Repairs · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6260945
9 September 2015
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5751351
29 September 2014
MTSA Verification · Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4991729
30 September 2013
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4726273
3 August 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4400114
13 June 2011
Drydock Exam · Internal Structural Exam · MTSA Verification · Cargo Tank Internal · Examination of Repairs · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4039342
2 June 2011
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4031238
17 August 2010
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3826753
12 August 2010
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3822084
9 July 2009
Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3529283
31 January 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3403429
18 July 2008
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3260441
11 August 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3036248
9 July 2007
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2981702
2 June 2006
COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2664313
24 August 2005
MTSA Verification · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2471368
19 April 2005
MTSA Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2337662
24 May 2004
Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2076410
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979017
11 December 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1962765
22 August 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1883656
6 May 2003
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1787416
10 December 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1784627
9 July 2002
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1643734
5 June 2001
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440497
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2022
Resolved
Scantlings, materials and workmanship shall be at least equivalent to the requirements of ABS or other recognized classification society. Vessel made contact with Krotz Springs Railroad Bridge. Provide satisfactory survey of vessel for approval to USCG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2022
Resolved 16 December 2022
Resolution: Survey noted no damage.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 September 2014
Resolved
Tank level outlet weather proof box not weather tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2014
Resolution: Replaced gasket weather tight.
Deck/Cargo › Cargo Stowage › General
Issued 29 September 2014
Resolved
Port Slop Tank Rising Stick Gauge magnet missing. May conduct cargo ops except to affected slop tank until gauge is operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2014
Resolved 20 October 2014
Resolution: Replaced with new.
Deck/Cargo › Cargo Stowage › General
Issued 2 June 2011
Resolved
Vessel cargo tank inspection exp provide barge for CG INSPECTION
Action required: 705 - Other - as specified
Due 16 June 2011
Resolved 16 June 2011
Construction/Loadline › Hull › Hull Plating
Issued 2 June 2011
Resolved
Vessel is to be provide to CG Marine inspection due to lapse of Dry Dock credit.
Action required: 705 - Other - as specified
Due 16 June 2011
Resolved 16 June 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 June 2011
Resolved
Vessel coi exp provide barge COI inspection no later 06 -16 2011
Action required: 705 - Other - as specified
Due 16 June 2011
Resolved 13 June 2011
Resolution: COI inspection conducted by Sector New Orleans.