MAURY USCG vessel records
← All vessels

M. V. JOHN H.

M. V. JOHN H. is a 1989 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in June 2026, along with 31 deficiencies — 1 with no resolution recorded — and 5 casualty investigations between 2007 and 2015.

Records from 2007 to 2026. Most recent: inspection, 3 June 2026.

Built
1989
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAC6768
329171
Flag
UNITED STATES
Maury page id
psix-329171

Documentation record

Registered dimensions (L × B × D)229.7 ft × 36.0 ft × 13.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHIPBUILDING MARINE REPAI · PANAMA CITY, FL, UNITED STATES · built 1989
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 August 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each; 2 vessels inspected with it, by name and date; 5 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE HENLOPEN Passenger (Inspected) · MISLE 76670 · 24 June 2023 · activity 7863301JESSICA W Passenger (Inspected) · MISLE 683731 · 24 June 2023 · activity 7863301

Inspection history · 23

3 June 2026 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8387499
10 September 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8229403
30 December 2024 Examination of Repairs · Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8051177
1 November 2023 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7818528
24 June 2023 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7863301
12 January 2023 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7620650
21 September 2022 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7543272
23 August 2022 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536025
23 December 2021 Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7371986
3 November 2021 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7344111
1 September 2021 In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7301144
9 February 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7138843
4 December 2020 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7105765
6 April 2020 Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935963
23 October 2019 Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6837148
5 February 2019 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6620363
19 December 2018 MTSA Verification · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6600333
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526079
17 January 2018 Examination of Repairs · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6339321
25 September 2017 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6274750
3 April 2017 Inclining Experiment
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6117047
23 December 2016 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6063128
19 October 2016 Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6026537

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 June 2026 No resolution recorded
Void #8: Crop and renew aft blkd at port hatch entrance and transverse frame on the fwd side of the hatch.
Action required: 705 - Other - as specified
Due 8 September 2026
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 September 2025 Resolved
Secure 03 E/R overhead light with metal supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 17 September 2025
Resolution: Recieved pictures from vessel rep. showing new lighting fixtures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022 Resolved
All cable and wires must be installed with metal supports spaced not more then 24 inches apart. Inspector opserved a wire in the port side of the E/R hanging unsupported.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 1 February 2023
Resolution: Wires that were identified have been supported.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022 Resolved
Each lighting fixture must have a guard. Inspector observed 02 lighting fixtures in the E/R without guards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 1 February 2023
Resolution: Guards installed.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 9 February 2021 Resolved
The fixed firefighting system alarm to alert the crew before discharge of the HALON was not producing sound.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2021
Resolution: Vessel rep replaced non-working horn. Re tested the alarm and passed satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 December 2020 Resolved
Void #8 crop ad renew wasted bottom long to good metal under port shaft as marked. Crop and renew wasted deep floor to good metal 2nd bay stbd of CL iwo deck plate and fwd blkd.
Action required: 705 - Other - as specified
Due 30 December 2020
Resolved 7 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019 Resolved
Lifebuoy grab line was deteriorated.
Action required: 10 - Deficiency Rectified
Due 23 October 2019
Resolved 23 October 2019
Resolution: New Lifebuoy installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2019 Resolved
One fire hose was found with a hole during pressure test.
Action required: 10 - Deficiency Rectified
Due 23 October 2019
Resolved 23 October 2019
Resolution: New fire hose installed on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 December 2018 Resolved
4 emergency lights needed new light bulbs. Bulbs were replaced during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 December 2018
Resolved 19 December 2018
Resolution: bulbs were replced during the inspection
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018 Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2018
Resolved 19 December 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 18 October 2017 Resolved
Secure light in Crew only locker IWO M/F rest room.
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 October 2017 Resolved
Install covers on 3 junction boxes.
Due 19 November 2017
Resolved 18 October 2017
Resolution: covers installed
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 October 2017 Resolved
Install juction box cover in galley.
Due 19 November 2017
Resolved 18 October 2017
Resolution: cover installed
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 18 October 2017 Resolved
Install self closing device for all galley doors and show operation of magnet door release system.
Due 19 November 2017
Resolved 17 January 2018
Resolution: Tested self closing devices for doors.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 18 October 2017 Resolved
Label and show proper operation of emergency vent in galley
Due 19 November 2017
Resolved 18 October 2017
Resolution: vent adjusted and labeled.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 October 2017 Resolved
De-grease galley vent.
Due 19 November 2017
Resolved 31 October 2017
Communications › Internal Communications System › Sound-powered Telephone
Issued 18 October 2017 Resolved
Repair sound powered phone P/S main car deck
Due 19 November 2017
Resolved 1 February 2018
Resolution: Sound power phones are no longer used. Crew uses radios.
Accommodation/Occupational Safety › Heating › Piping
Issued 18 October 2017 Resolved
Repair leaking heating pipe clean/inspect IWO STBD hatch in steering space
Due 19 November 2017
Resolved 13 November 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 October 2017 Resolved
Inspect all adult lifejackets retro tape and repair where nessary.
Due 19 November 2017
Resolved 13 November 2017
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 18 October 2017 Resolved
Label waste oil motor control pump on main car deck.
Due 19 November 2017
Resolved 18 October 2017
Resolution: pump labeled.
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 25 September 2017 Resolved
Pump controler was not labled on car deck
Due 19 November 2017
Resolved 13 November 2017
Fire Fighting › Fire Main › Condition
Issued 25 September 2017 Resolved
Leak noted in pipe just above fire pump
Due 19 November 2017
Resolved 19 October 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 25 September 2017 Resolved
Two light fixtures in engine room required covers
Due 18 November 2017
Resolved 19 October 2017
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 25 September 2017 Resolved
Remove or blank off old piping from old heating system just above the boiler
Due 19 November 2017
Resolved 13 November 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 September 2017 Resolved
Secure junction box to bulkhead located aft in the bow thruster space
Due 19 November 2017
Resolved 13 November 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 September 2017 Resolved
Remove remote valve for bow thruster fuel tank
Due 18 October 2017
Resolved 18 October 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 September 2017 Resolved
Watertight door located in the engine room was not operating properly
Due 18 October 2017
Resolved 19 October 2017
Construction/Loadline › Structures › Door
Issued 25 September 2017 Resolved
Doors to passenger area would not close properly
Due 18 November 2017
Resolved 13 November 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 September 2017 Resolved
Door to engine room was missing the door handle
Due 18 November 2017
Resolved 13 November 2017
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2017 Resolved
Repair High Level Alarm in void #5
Due 19 November 2017
Resolved 13 November 2017
Engineering › Bilge Water Management System › Strainer
Issued 25 September 2017 Resolved
Provide strainer for bilge suction
Due 18 November 2017
Resolved 13 November 2017

Casualty record · 5

20 April 2007Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 2914399
24 November 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3900255
19 January 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4282543
26 May 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4342955
8 July 2015Routine · role: Involved in a Marine Casualty · activity 5185918
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.