Inspection history · 23
3 June 2026
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8387499
10 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8229403
30 December 2024
Examination of Repairs · Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8051177
1 November 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7818528
24 June 2023
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7863301
12 January 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7620650
21 September 2022
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7543272
23 August 2022
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536025
23 December 2021
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7371986
3 November 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7344111
1 September 2021
In-Service Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7301144
9 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7138843
4 December 2020
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7105765
6 April 2020
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935963
23 October 2019
Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6837148
5 February 2019
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6620363
19 December 2018
MTSA Verification · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6600333
29 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6526079
17 January 2018
Examination of Repairs · Construction Oversight
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6339321
25 September 2017
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6274750
3 April 2017
Inclining Experiment
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6117047
23 December 2016
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6063128
19 October 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6026537
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 June 2026
No resolution recorded
Void #8: Crop and renew aft blkd at port hatch entrance and transverse frame on the fwd side of the hatch.
Action required: 705 - Other - as specified
Due 8 September 2026
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 September 2025
Resolved
Secure 03 E/R overhead light with metal supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 17 September 2025
Resolution: Recieved pictures from vessel rep. showing new lighting fixtures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022
Resolved
All cable and wires must be installed with metal supports spaced not more then 24 inches apart. Inspector opserved a wire in the port side of the E/R hanging unsupported.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 1 February 2023
Resolution: Wires that were identified have been supported.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022
Resolved
Each lighting fixture must have a guard. Inspector observed 02 lighting fixtures in the E/R without guards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2022
Resolved 1 February 2023
Resolution: Guards installed.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 9 February 2021
Resolved
The fixed firefighting system alarm to alert the crew before discharge of the HALON was not producing sound.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2021
Resolution: Vessel rep replaced non-working horn. Re tested the alarm and passed satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 4 December 2020
Resolved
Void #8 crop ad renew wasted bottom long to good metal under port shaft as marked. Crop and renew wasted deep floor to good metal 2nd bay stbd of CL iwo deck plate and fwd blkd.
Action required: 705 - Other - as specified
Due 30 December 2020
Resolved 7 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2019
Resolved
Lifebuoy grab line was deteriorated.
Action required: 10 - Deficiency Rectified
Due 23 October 2019
Resolved 23 October 2019
Resolution: New Lifebuoy installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2019
Resolved
One fire hose was found with a hole during pressure test.
Action required: 10 - Deficiency Rectified
Due 23 October 2019
Resolved 23 October 2019
Resolution: New fire hose installed on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 December 2018
Resolved
4 emergency lights needed new light bulbs. Bulbs were replaced during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 December 2018
Resolved 19 December 2018
Resolution: bulbs were replced during the inspection
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018
Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2018
Resolved 19 December 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 18 October 2017
Resolved
Secure light in Crew only locker IWO M/F rest room.
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 October 2017
Resolved
Install covers on 3 junction boxes.
Due 19 November 2017
Resolved 18 October 2017
Resolution: covers installed
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 October 2017
Resolved
Install juction box cover in galley.
Due 19 November 2017
Resolved 18 October 2017
Resolution: cover installed
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 18 October 2017
Resolved
Install self closing device for all galley doors and show operation of magnet door release system.
Due 19 November 2017
Resolved 17 January 2018
Resolution: Tested self closing devices for doors.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 18 October 2017
Resolved
Label and show proper operation of emergency vent in galley
Due 19 November 2017
Resolved 18 October 2017
Resolution: vent adjusted and labeled.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 October 2017
Resolved
De-grease galley vent.
Due 19 November 2017
Resolved 31 October 2017
Communications › Internal Communications System › Sound-powered Telephone
Issued 18 October 2017
Resolved
Repair sound powered phone P/S main car deck
Due 19 November 2017
Resolved 1 February 2018
Resolution: Sound power phones are no longer used. Crew uses radios.
Accommodation/Occupational Safety › Heating › Piping
Issued 18 October 2017
Resolved
Repair leaking heating pipe clean/inspect IWO STBD hatch in steering space
Due 19 November 2017
Resolved 13 November 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 October 2017
Resolved
Inspect all adult lifejackets retro tape and repair where nessary.
Due 19 November 2017
Resolved 13 November 2017
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 18 October 2017
Resolved
Label waste oil motor control pump on main car deck.
Due 19 November 2017
Resolved 18 October 2017
Resolution: pump labeled.
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 25 September 2017
Resolved
Pump controler was not labled on car deck
Due 19 November 2017
Resolved 13 November 2017
Fire Fighting › Fire Main › Condition
Issued 25 September 2017
Resolved
Leak noted in pipe just above fire pump
Due 19 November 2017
Resolved 19 October 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 25 September 2017
Resolved
Two light fixtures in engine room required covers
Due 18 November 2017
Resolved 19 October 2017
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 25 September 2017
Resolved
Remove or blank off old piping from old heating system just above the boiler
Due 19 November 2017
Resolved 13 November 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 September 2017
Resolved
Secure junction box to bulkhead located aft in the bow thruster space
Due 19 November 2017
Resolved 13 November 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 September 2017
Resolved
Remove remote valve for bow thruster fuel tank
Due 18 October 2017
Resolved 18 October 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 25 September 2017
Resolved
Watertight door located in the engine room was not operating properly
Due 18 October 2017
Resolved 19 October 2017
Construction/Loadline › Structures › Door
Issued 25 September 2017
Resolved
Doors to passenger area would not close properly
Due 18 November 2017
Resolved 13 November 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 September 2017
Resolved
Door to engine room was missing the door handle
Due 18 November 2017
Resolved 13 November 2017
Engineering › Bilge Water Management System › Not Operational
Issued 25 September 2017
Resolved
Repair High Level Alarm in void #5
Due 19 November 2017
Resolved 13 November 2017
Engineering › Bilge Water Management System › Strainer
Issued 25 September 2017
Resolved
Provide strainer for bilge suction
Due 18 November 2017
Resolved 13 November 2017