JESSICA W

JESSICA W is a passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 2004, most recently in January 2026, along with 89 deficiencies, 2 operational controls and 8 casualty investigations between 2007 and 2017.

Records from 2004 to 2026. Most recent: inspection, 12 January 2026.

Built
Not recorded
Last inspected
12 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8906717 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB8889
683731
Flag
UNITED STATES
366965960
Maury page id
psix-683731

Inspections, by type

…with no type recorded19
Years with a record 22 calendar years (2004–2026)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)137.8 ft × 59.7 ft × 18.2 ft
Registered tonnagegross 451 / net 284
ITC dimensions (L × B × D)137.8 ft × 59.7 ft × 18.2 ft
ITC tonnagegross 752 / net 225
BuilderNot recorded
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it752 - Convention (Subpart B), Gross Ton
451 - Regulatory (Subpart C or D), Gross Ton
225 - Convention (Subpart B), Net Ton
284 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8889MMSI 366965960 · active · compulsorily equipped · granted 1 May 2024, expires 21 July 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

Inspection history · 94

12 January 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8294976
11 June 2025 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8155417
27 June 2024 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7941881
12 June 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7933444
24 June 2023 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7863301
15 June 2023 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7706555
13 June 2022 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7470968
12 November 2021 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7384793
11 August 2021 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7282512
2 April 2021 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7164799
20 November 2020 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7098992
14 July 2020 Examination of Repairs · MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7001515
18 October 2019 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6837178
19 September 2019 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6815527
19 June 2019 COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6712940
29 April 2019 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6672627
5 November 2018 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6574811
2 October 2018 Security Breach
Type not classified · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6558649
27 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6524474
27 May 2018 Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6428042
23 May 2018 COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6414409
2 September 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6259266
2 September 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6259273
24 August 2017 Security Breach
Type not classified · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6251586
6 August 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6261957
3 August 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6230636
4 July 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6197982
4 July 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6198308
4 July 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6198323
4 July 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6198340
15 June 2017 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6176588
31 May 2017 COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6141548
17 May 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6154448
23 September 2016 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6015986
1 July 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5932573
13 June 2016 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5906322
25 May 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5886315
16 May 2016 COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5884101
1 April 2016 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5850037
12 January 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5795826
1 September 2015 Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5232062
29 October 2014 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5015741
22 October 2014 Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5011600
9 May 2014 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4854261
7 May 2014 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4852783
11 March 2014 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4814135
20 July 2012 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4385070
4 July 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4367295
4 July 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4367308
21 June 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4351126
20 June 2012 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4351142
11 May 2012 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4308372
14 February 2012 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4244323
10 February 2011 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3943642
21 September 2010 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3854773
9 March 2010 DAPI Audit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3692640
5 January 2010 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3659548
17 December 2009 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3652321
12 May 2009 COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3468884
14 April 2009 Examination of Repairs · Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3449402
17 September 2008 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3326703
6 August 2008 In-Service Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3291608
30 May 2008 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3222052
9 May 2008 MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3202527
18 March 2008 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3165974
2 November 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3415981
19 September 2007 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3065553
20 June 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2970417
14 June 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2962477
14 May 2007 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2925300
9 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2906593
26 September 2006 Periodic Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2787864
1 June 2006 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2667170
24 May 2006 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2657550
12 May 2006 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2647304
12 April 2006 Re-Inspection · Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2623117
31 January 2006 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2577251
20 September 2005 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2497086
21 August 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2472422
11 August 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2459640
19 July 2005 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2431858
8 July 2005 MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2419857
15 June 2005 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2391451
19 May 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2362273
15 March 2005 Examination of Repairs
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2310355
11 February 2005 Plan Review (Other than "T")
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2291944
31 January 2005 Plan Review (Other than "T") · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2283962
15 November 2004 Examination of Repairs
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2241228
2 November 2004 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2233267
12 August 2004 Initial Certification
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2175069
5 August 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2157328
7 July 2004 Plan Review (Other than "T")
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2125197
8 April 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2115917
16 March 2004 Examination of Repairs · Deadweight Survey · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2139042

Deficiency record · 89

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 June 2022 Resolved
Crew failed fire drill due to lack of positive communication.
Action required: 10 - Deficiency Rectified
Due 13 June 2022
Resolved 13 June 2022
Resolution: After a debrief the crew performed a satisfactory fire drill.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 August 2021 Resolved
Vessels stern navigation light is not duel filament. Equip stern light with duel filament fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 30 November 2021
Resolution: Witnessed operational test of stern light
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 14 July 2020 Resolved
Replace rescue boat falls and conduct a 1.1 overload weight tet in the presence of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 23 July 2020
Resolution: New wire falls installed and 110% overload test conducted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2020 Resolved
Port generator room fixed CO2 pilot bottle is low and needs to be recharged.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 22 July 2020
Resolution: Pilot bottle was replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 July 2020 Resolved
Crop and renew hole found in void #4 port side.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 22 July 2020
Resolution: The hole was cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 July 2020 Resolved
Clean and de-scale all voids and make available for ISE by CG.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 22 July 2020
Resolution: Voids cleaned and an addition CG ISE was conducted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2020 Resolved
Prove proper operation of high level bilge alarm in stbd jet room and stbd void #2.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 23 July 2020
Resolution: New bilge alarms were installed and tested.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 14 July 2020 Resolved
Clean aft galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 23 July 2020
Resolution: Galley was cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 July 2020 Resolved
Prove proper operation of stbd E/R remote operated fire dampers.
Action required: 10 - Deficiency Rectified
Due 14 July 2020
Resolved 14 July 2020
Resolution: fire dampers repaird and operationally tested.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 July 2020 Resolved
Prove proper operation of of port generator room CO2 time delay.
Action required: 10 - Deficiency Rectified
Due 14 July 2020
Resolved 14 July 2020
Resolution: New time delay installed and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 July 2020 Resolved
Automatic fire screen door on the stbd side closed to fast.
Action required: 10 - Deficiency Rectified
Due 14 July 2020
Resolved 14 July 2020
Resolution: FSD was adjusted and closed sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2020 Resolved
Replace broken grab line on life ring in 02 deck port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 23 July 2020
Resolution: Life ring was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 14 July 2020 Resolved
Complete periodic safety test procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 23 July 2020
Resolution: All PSTP tests were completed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2020 Resolved
Complete annual servicing of portable fire extingushers.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2020
Resolved 14 July 2020
Resolution: Portable extiguishers serviced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2019 Resolved
Heat detector Z05 in the stbd engine room is showing a fault on the fire panel. The heat detector was tested with a blow torch and did alarm in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 July 2020
Resolution: Heat detector replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2019 Resolved
The control panel for the throttle and bucket control system was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 June 2019
Resolved 20 June 2019
Resolution: Manufacturers tech attended the vessel and id'd the problem as a faulty ground. Replaced control panel and conducted satisfactory testing and sea trial.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is not broadcasting an IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: completed
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 31 May 2017 Resolved
#1 and #2 main engine reduction gear lost lube oil pressure during RPM engine drop
Due 1 July 2017
Resolved 4 August 2017
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 31 May 2017 Resolved
Unauthorized pressure guage was attached to fuel line
Due 1 June 2017
Resolved 1 June 2017
Resolution: Guage removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 31 May 2017 Resolved
Remove clutter from engine room ventilation shafts
Due 1 July 2017
Resolved 15 June 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2017 Resolved
Secure all electrical wiring in the engine room and generator room
Due 1 July 2017
Resolved 15 June 2017
Electrical › Electric Generation Source (emergency) › Generator
Issued 31 May 2017 Resolved
Repair low lube oil and high jacket water alarms and shut downs
Due 15 June 2017
Resolved 15 June 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 May 2017 Resolved
Hydro test all nitrogen bottles
Due 9 June 2017
Resolved 9 June 2017
Resolution: Bottles hydro-tested.
Electrical › Electric Generation Source (service) › Generator
Issued 26 May 2016 Resolved
High water temp shut downs did not work on both port and stbd generators as per the service manual.
Due 26 June 2016
Resolved 1 July 2016
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 26 May 2016 Resolved
Fire resistant gasket around door frame was torn and worn.
Due 26 June 2016
Resolved 29 June 2016
Engineering › Thrusters › Tunnel
Issued 1 April 2016 Resolved
Redo stern tube, port side, inboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 26 May 2016
Construction/Loadline › Hull › Longitudinal Frame
Issued 1 April 2016 Resolved
In the sewage void 1st frame bay aft of forward bulkhead crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 26 May 2016
Engineering › Sea-water System (primary cooling) › Valve
Issued 1 April 2016 Resolved
Make all sea valves ready for inspection.
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 26 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2015 Resolved
Remove dead ended wires located adjacent to the windshield wiper switch/motors located in the wheel house
Due 30 September 2015
Resolved 12 January 2016
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 September 2015 Resolved
Provide additional supports for potable water line on fantail to eliminate the line from resting on electrical cables
Due 30 September 2015
Resolved 12 January 2016
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 1 September 2015 Resolved
Replace missing fire resistant insulation around the door frame for e-generator room access door, engine room door and port engine room overhead around hydraulic line penetrations.
Due 30 September 2015
Resolved 26 May 2016
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 22 October 2014 Resolved
Repair/Replace shaft TACH guage on PORT/STBD outboard operating stations.
Due 22 November 2014
Resolved 29 October 2014
Resolution: Tach on both operating stations are operable.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 October 2014 Resolved
Organize cabinet in pilot house. Capt of vessel had difficult time finding required material in cabinet.
Due 22 November 2014
Resolved 27 October 2014
Resolution: Owner has purchased cabinet and organized area.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 22 October 2014 Resolved
Repair Echo-sounding device. Device was not working on the bridge.
Action required: 705 - Other - as specified
Due 31 December 2014
Resolved 28 May 2015
Resolution: Echo-sounding device is properly working.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 October 2014 Resolved
Clean Deli deck under cabinets.
Due 22 November 2014
Resolved 29 October 2014
Resolution: Deli cabinets were cleaned.
Engineering › Fuel Oil Service System › Hose
Issued 22 October 2014 Resolved
Renew F/O supply hoses on PORT/STBD filters on AFT engines.
Due 22 December 2014
Resolved 29 October 2014
Resolution: F/O hoses were renewed.
Lifesaving › Rescue Boat Equipment › Boat-hook/Safety Boat-hook
Issued 11 March 2014 Resolved
Provide cover on rescue boat emer. release mech.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Sighted cover in place.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 11 March 2014 Resolved
Provide B1 extinguisher for rescue boat.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: B1 extinguisher stored in the rescue boat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 March 2014 Resolved
Replace water light (top) on aft ring buoy.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Sighted water light with new top
Fire Fighting › Nozzles › Condition
Issued 11 March 2014 Resolved
Attach chain on nozzle tip F.S. #6.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Sighted chain on nozzle
Lifesaving › Emergency Outfit › Fire ax
Issued 11 March 2014 Resolved
Label fire axe location port aft.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Sighted lable
Communications › Internal Communications System › Sound-powered Telephone
Issued 11 March 2014 Resolved
Repair or remove phone fwd main cabin.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Conducted operational test of the phone with main control, sat
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 March 2014 Resolved
Replace stripped screw on handrail, stbd side behind pilot house.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Both handrails were refastened and are now secure.
Fire Fighting › Nozzles › Condition
Issued 11 March 2014 Resolved
Provide tip for nozzle @F.S.#3
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Sighted tip for nozzle
Fire Fighting › Ventilation Systems › Ducts
Issued 11 March 2014 Resolved
Label and prove operational of stbd fire damper.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 5 June 2014
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 March 2014 Resolved
Remove water from battery box (nav. backup)
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Water was removed
Engineering › Bilge Water Management System › Valve
Issued 11 March 2014 Resolved
Repair reach ro for port forepeak.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 10 June 2014
Resolution: Conducted sat operational test of the reach rod
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 March 2014 Resolved
Prove operation of high bilge alarm in port forepeak.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 5 June 2014
Fire Fighting › Structural Fire Protection - General › Column/Stanchion Construction
Issued 11 March 2014 Resolved
Repair welds on stanchion in port fuel tank void.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 10 June 2014
Resolution: Stanchion re-welded
Stability › Watertight Integrity › General
Issued 11 March 2014 Resolved
Prove operation of WTD lever in port E/R (weak detent)
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 5 June 2014
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 March 2014 Resolved
Prove operation of "E" light in pax cabin stbd.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 10 June 2014
Resolution: E Lights tested sat
Lifesaving › Launching Appliances › Falls
Issued 11 March 2014 Resolved
Renew falls on rescue boat davit
Action required: 705 - Other - as specified
Due 30 September 2014
Resolved 11 September 2014
Resolution: Falls renewed and tested IAW Rescue boat test procedures in Subchapter Q
Engineering › Bilge Water Management System › Piping
Issued 11 March 2014 Resolved
Make permanent repairs to bilge suction piping port E.R. outbd
Action required: 705 - Other - as specified
Due 31 December 2014
Resolved 21 May 2015
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 July 2012 Resolved
PROVE OPERATION OF EMERGENCY LIGHING IN PORT ENGINE ROOM VESTIBLE
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 October 2012
Resolution: Properly operating
Engineering › Fuel Oil Service System › Filter
Issued 20 July 2012 Resolved
REPAIR FUEL LEAKS ON #3 MDE
Action required: 705 - Other - as specified
Due 23 July 2012
Resolved 23 July 2012
Resolution: REPAIRED FUEL LEAK ON #3 MDE
Engineering › Lubricating Oil Service System › Hose
Issued 20 July 2012 Resolved
REPLACE L/O GEAR HOSE GOING INTO FILTER ON #2 MDE
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 October 2012
Resolution: Hose replaced
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 July 2012 Resolved
MAKE PERMANENT REPAIRS TO S/W DISCHARGE PIPING ON #'S 1, 2, AND 3 MDE
Action required: 705 - Other - as specified
Resolved 15 May 2013
Resolution: S/W discharge piping replaced.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 July 2012 Resolved
REPAIR EXHAUST LEAKS ON #1 MDE
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 October 2012
Resolution: Exhaust leak repaired
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 July 2012 Resolved
REPAIR J/W LEAKS ON #'S 3 AND 4 MDE EXPANSION TANKS
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 October 2012
Resolution: Leaks repaired
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 20 July 2012 Resolved
REPLACE EXPANSION JOINT ON J/W DISCHARGE ON #3 MDE
Action required: 705 - Other - as specified
Resolved 15 May 2013
Resolution: J/W discharge piping replaced.
Accommodation/Occupational Safety › Ventilation › General
Issued 20 July 2012 Resolved
CAP OFF OLD AC PIPES IN PORT VENT ROOM UPPER DECK FOR STRUCTURAL FIRE PURPOSES
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 October 2012
Resolution: Vent capped
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 February 2012 Resolved
Mark/stencil location of first aid kit.
Due 28 February 2012
Resolved 13 March 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 February 2012 Resolved
Mark/Stencil CO2 pull station control for emergency generator room.
Due 28 February 2012
Resolved 13 March 2012
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 14 May 2007 Resolved
Provide handle for lower dog on the forward weather tight door on the main passenger deck.
Condition: Improper/Lack of Maintenance
Due 22 May 2007
Resolved 14 June 2007
Resolution: Handle provided.
Deck/Cargo › Holds/Tanks › Coaming
Issued 14 May 2007 Resolved
Prove proper operation of port watertight door.
Condition: Improper/Lack of Maintenance
Due 22 May 2007
Resolved 20 June 2007
Resolution: WTD repaired and tested satisfactory.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 May 2007 Resolved
Replace bulbs in 2 emergency lighting fixtures on the main passenger deck and 2 fixtures on the 01 deck.
Condition: Improper/Lack of Maintenance
Due 22 May 2007
Resolved 20 June 2007
Resolution: Bulbs replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 May 2007 Resolved
Conduct servicing on portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 22 May 2007
Resolved 14 June 2007
Resolution: Extinguishers serviced.
Electrical › Electrical Distribution System (service) › Cable
Issued 14 May 2007 Resolved
Replace plastic cable ties with metal banding.
Due 14 June 2007
Resolved 18 March 2008
Resolution: Cable ties replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 14 May 2007 Resolved
Calibrate pilot house and ECC tachometers for the #4 engine.
Due 22 May 2007
Resolved 14 June 2007
Resolution: Tachometer calibrated.
Engineering › Feedwater/Condensate Water System › Gauge
Issued 14 May 2007 Resolved
Repair / repalce salt water pressure gauge for aft port MDE.
Due 14 June 2007
Resolved 14 June 2007
Resolution: Gauge replaced.
Engineering › Lubricating Oil Service System › Gauge
Issued 14 May 2007 Resolved
Repair / Repalce out board MDE L/O Gauge.
Due 14 June 2007
Resolved 20 June 2007
Resolution: Gauge replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 May 2007 Resolved
Prove maintenence of fire extinguishers
Due 24 May 2007
Resolved 14 June 2007
Resolution: Extinguishers serviced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 September 2006 Resolved
Install proper release pins for aft gates on port and starboard side.
Condition: Improper/Lack of Maintenance
Due 3 October 2006
Resolved 26 April 2007
Resolution: Pins provided.
Engineering › Lubricating Oil Service System › Gauge
Issued 26 September 2006 Resolved
Prove proper operation of the J/W Temp, L/O Temp, L/O Pressure gauges in ECC.
Condition: Improper/Lack of Maintenance
Due 3 October 2006
Resolved 20 June 2007
Resolution: Gauges replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 June 2006 Resolved
Repair pin hole leaks on STBD forward MDE sea water cooling line.
Due 16 June 2006
Resolved 20 June 2006
Resolution: Weld repairs have been made
Engineering › Fuel Oil Service System › Piping
Issued 1 June 2006 Resolved
Make repairs to Port FWS MDE fuel lines. (Excessive leakage thru leak back piping)
Due 16 June 2006
Resolved 20 June 2006
Resolution: New Leak back line has been installed and tested SAT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 June 2006 Resolved
Test time delays in presence of marine inspector
Due 16 June 2006
Resolved 20 June 2006
Resolution: Time delays have been inspected, SAT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 June 2006 Resolved
Test CO2 Shutdowns in presence of marine inspector for all fixed co2 systems
Due 16 June 2006
Resolved 20 June 2006
Resolution: CO2 Shutdowns tested, SAT
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 1 June 2006 Resolved
Label aft lifejacket locker
Due 16 June 2006
Resolved 20 June 2006
Resolution: Aft lifejacket locker is labeled.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 1 June 2006 Resolved
Prove operation of fire dampers for aft accomodation spaces.
Due 16 June 2006
Resolved 20 June 2006
Resolution: Fire Dampers operate
Stability › Watertight Integrity › General
Issued 1 June 2006 Resolved
Prove proper operation of port engine room WTD.
Due 16 June 2006
Resolved 20 June 2006
Resolution: Port E/R WTD operates SAT.
Fire Fighting › Means of Escape › Doorways
Issued 12 April 2006 Resolved
Repair & test main deck door closures to both engine room entrances.
Condition: Improper/Lack of Maintenance
Due 28 April 2006
Resolved 11 May 2006
Resolution: Completed.
Engineering › Bilge Water Management System › Valve
Issued 20 September 2005 Resolved
Repair forepeak bilge valve reach rod supports port & stbd hulls as needed.
Condition: Damaged By Earlier Event
Due 4 October 2005
Resolved 12 April 2006
Resolution: Test sat.
Construction/Loadline › Structures › Scuttle
Issued 15 June 2005 Resolved
Provide capture chains for external deck hatches.
Due 30 June 2005
Resolved 19 July 2005
Resolution: 07/19/05: Attended vessel for DEF check. Capture Chains have been installed on external deck hatches. [name withheld]
Communications › Audible Communications › SPD (Other)
Issued 15 June 2005 Resolved
Prove proper operation of STBD generator room telephone.
Due 30 June 2005
Resolved 19 July 2005
Resolution: 07/19/05: Attended vessel for DEF Check. Starboard Generator Room Telephone tested SAT. [name withheld]
Communications › Audible Communications › SPD (Other)
Issued 15 June 2005 Resolved
Repair talkback speaker on 01 deck fwd.
Due 30 June 2005
Resolved 19 July 2005
Resolution: 07/19/05: Attended vessel for DEF Check. Speaker in 01 deck has been repaired and tested SAT. [name withheld]
Engineering › Bilge Water Management System › Valve
Issued 31 January 2005 Resolved
Install check valve as required by MSC letter of 20 Dec. 2004 on all bilge pipes within 3.5' of the side shell
Due 28 February 2005
Resolved 14 March 2005
Engineering › Bilge Water Management System › Piping
Issued 12 August 2004 Resolved
Vessel bilge system to comply with approved drawing C-1045-11 ALT2 no later than 12SEP04.
Due 12 August 2004
Resolved 31 January 2005
Resolution: Cleared this CG 835, issued CG 835 to come in compliance with MSC ltr of 20 DEC 2004
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 12 August 2004 Resolved
Renew wasted Hyd coupling for anchor windlass.
Due 17 September 2004
Resolved 14 March 2005

Casualty record · 8

4 August 2007Routine · role: Involved in a Marine Casualty · activity 3019816
23 March 2012Routine · role: Involved in a Marine Casualty · activity 4284336
21 September 2012Routine · role: Involved in a Marine Casualty · activity 4465160
6 July 2013Routine · role: Involved in a Marine Casualty · 1 injured · activity 4698374
30 July 2013Routine · role: Involved in a Marine Casualty · activity 4952467
18 August 2013Routine · role: Subject to Marine Inspection · activity 4756911
3 August 2017Routine · role: Involved in a Marine Casualty · activity 6230636
6 August 2017Routine · role: Involved in a Marine Casualty · activity 6261957
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.