MAURY USCG vessel records Sign in
← All vessels

CAPE HENLOPEN

CAPE HENLOPEN is a 1944 passenger vessel (inspected). The Coast Guard has recorded 180 inspections since 1985, most recently in May 2026, along with 318 deficiencies and 11 casualty investigations between 2008 and 2024.

Records from 1985 to 2026. Most recent: inspection, 12 May 2026.

Built
1944
Last inspected
12 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5381978 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WM5958
Flag
UNITED STATES
367354360
Maury page id
psix-76670

Inspections, by type

…with no type recorded38
Years with a record 41 calendar years (1985–2026)
The 180 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)307.6 ft × 50.1 ft × 10.3 ft
Registered tonnagegross 1,492 / net 799
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · JEFFERSONVILLE, IN, UNITED STATES · built 1944
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW LONDON, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1492 - Regulatory (Subpart C or D), Gross Ton
799 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WM5958MMSI 367354360 · active · compulsorily equipped · granted 5 May 2018, expires 21 July 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 5

Inspection history · 180

12 May 2026 COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8354887
1 April 2026 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8343444
21 January 2026 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8299550
13 August 2025 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8212683
14 May 2025 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8133100
31 January 2025 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8070214
18 September 2024 Deficiency Check · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8005247
18 September 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8012601
29 August 2024 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7992292
20 June 2024 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7932350
15 April 2024 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7896292
26 January 2024 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7856372
25 October 2023 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7814644
26 July 2023 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7751965
24 June 2023 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7863301
20 April 2023 COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7654279
9 January 2023 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7618340
24 August 2022 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536070
16 May 2022 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7453202
27 April 2022 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7419850
20 February 2022 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7400753
9 February 2022 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7392553
23 December 2021 Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7371967
8 September 2021 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7306463
30 May 2021 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7389565
12 May 2021 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7179050
10 February 2021 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7138492
2 November 2020 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7087000
27 May 2020 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6957814
6 April 2020 Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935948
10 January 2020 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6885840
21 October 2019 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6837136
12 June 2019 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6712214
14 December 2018 MTSA Verification · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6597963
30 October 2018 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6573332
31 July 2018 Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6496796
9 April 2018 MTSA Verification · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6388271
18 January 2018 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6341685
14 October 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6327591
31 March 2017 COI Inspection · Deadweight Survey · Hull Examination · Internal Structural Exam · MTSA Verification · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6117068
14 October 2016 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6022311
28 July 2016 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5955791
2 June 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5895375
18 April 2016 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5856781
1 April 2016 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5847906
12 January 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5795835
1 December 2015 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5773292
2 November 2015 Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5755749
14 October 2015 Examination of Repairs · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5742731
12 October 2015 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5743422
6 August 2015 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5208576
22 October 2014 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5011029
15 May 2014 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4879187
8 June 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4337797
30 May 2012 MTSA Verification · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4319863
2 September 2011 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4134089
3 August 2011 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4104205
10 February 2011 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3943628
16 December 2010 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3912528
4 November 2010 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3884986
28 September 2010 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3858335
22 March 2010 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3701165
17 March 2010 Examination of Repairs · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3697474
16 March 2010 Damage Survey
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3696913
15 March 2010 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3698070
11 January 2010 Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3662565
9 July 2009 Plan Review (Other than "T")
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3554562
19 February 2009 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3420420
9 January 2009 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3392595
15 September 2008 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3325396
7 August 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3317479
9 July 2008 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3264465
7 July 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3289015
14 April 2008 Deadweight Survey · Internal Structural Exam · Hull Examination · Examination of Repairs · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3202484
2 November 2007 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3415981
2 October 2007 Re-Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3071412
20 June 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2970405
14 June 2007 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2962447
10 May 2007 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2925206
23 April 2007 Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2913832
19 September 2006 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2782320
15 September 2006 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2778828
20 June 2006 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2686236
19 May 2006 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2653220
28 October 2005 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2523946
14 September 2005 Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2492545
20 July 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2435424
19 July 2005 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2431869
8 July 2005 Deficiency Check · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2419836
22 June 2005 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2399468
19 May 2005 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2362201
9 May 2005 Re-Inspection · Examination of Repairs · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2352705
2 November 2004 Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2233260
25 October 2004 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2227671
3 June 2004 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2084907
21 May 2004 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2074402
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972335
17 December 2003 Quarterly Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1965426
1 December 2003 Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1956691
29 November 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1961056
10 September 2003 Quarterly Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1903473
12 June 2003 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1816079
17 May 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1807542
8 May 2003 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1789402
21 January 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1732881
13 November 2002 Quarterly Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1704964
28 June 2002 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1638480
16 May 2002 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1617700
11 January 2002 Quarterly Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1477983
23 May 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1362228
12 April 2001 Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1423507
23 January 2001 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1059567
3 October 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467256
10 August 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1053435
31 May 2000 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467682
24 May 2000 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1384443
14 December 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 812937
8 September 1999 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450350
13 May 1999 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450277
2 April 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 785827
14 December 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 213294
14 December 1998 Deficiency Check · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 798217
2 December 1998 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 806114
17 November 1998 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 805809
2 October 1998 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801861
18 May 1998 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 804722
6 May 1998 Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 800679
16 January 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1109485
14 November 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 784703
13 August 1997 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 783580
29 May 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 773589
20 May 1997 Deficiency Check · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 773543
24 March 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 795609
16 November 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 145257
11 November 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 174804
7 November 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 219962
28 October 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 230088
21 August 1996 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 854424
10 July 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084276
26 June 1996 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1402258
13 May 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1189160
5 December 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1189875
20 September 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187433
24 August 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1189411
9 May 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878981
29 March 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161486
20 June 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 117225
11 May 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870419
21 March 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 870417
24 August 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827645
24 August 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844363
19 July 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 69051
17 June 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137082
28 June 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 117396
19 May 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946719
6 May 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255114
16 August 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933565
9 May 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006578
25 April 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310018
18 December 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920866
2 July 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914924
23 May 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919107
23 May 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230188
18 May 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920302
3 May 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342521
17 August 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340915
30 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340906
16 July 1987 Examination of Repairs · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340862
26 May 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333243
15 April 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325721
14 April 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325724
24 September 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017877
28 August 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310127
21 May 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003084
17 May 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290961
29 October 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984874
20 August 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986475
22 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287757
16 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287755
10 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1292233

Deficiency record · 318

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 May 2026 Resolved
Fire main plug on the port side car deck found with a 1" hole. Renew valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2026
Resolved 13 May 2026
Resolution: New valve spool piece installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2025 Resolved
A-class door in-between galley to deli doesn’t shut
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Door fixed, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025 Resolved
Missing two bilge strainers, fuel tank void & ballast tank
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Strainers installed, all sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2025 Resolved
Replace high level bilge alarm in fuel tank void
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Replaced, all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 May 2025 Resolved
Numerous emergency lighting was inop (crew exit sign, 8 on car deck, P & S shaft alley, bow thruster, E/R, gen space, stbd maindeck aft exit)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Lighting replaced, all sat
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 May 2025 Resolved
Low water alarm in the boiler is inop
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Replaced switch, all sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2024 Resolved
A survey shall be made every time an accident occurs which affects the saftey of the vessel. Repair port shaft and propeller as in-kind. Vessel is restricted from carrying passengers until proper repair has been verified by a marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2024
Resolution: New shaft has been installed and aligned. Prop installed. Operational test conducted. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2024 Resolved
A survey shall be made every time an accident occurs which affects the saftey of the vessel. Due to the failure of the port shaft that resulted in the prop breaking off, an inspection of the starboard shaft and propeller is to be made to ensure integrity and prevent a similar occurance.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Witnessed NDT, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2024 Resolved
Flexible CO2 hoses on bow thruster system dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2024 Resolved
05 Sprinkler heads on the car deck blocked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 June 2024 Resolved
MI's observed 02 E lights on the car deck not working.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 20 June 2024 Resolved
General alarm bells not stenicled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 27 June 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2020 Resolved
Prove proper operation of generator room FM200 system.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2020
Resolved 28 May 2020
Resolution: FM200 bottle recharged and installed.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 May 2020 Resolved
Provide watertight door indicator light for WTD #4.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 27 May 2020
Resolution: Light bulb was replaced for the door and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2020 Resolved
Proved machanical interlock for main switch board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 28 May 2020
Resolution: Interlock re-installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2020 Resolved
Provide sight glass guard on port fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 28 May 2020
Resolution: Guard installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2020 Resolved
Provide new lifebuoy.
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 28 May 2020
Resolution: New lifebouy replaced on the spot
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 October 2019 Resolved
Complete compass deviation test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 27 May 2020
Resolution: Devaiationwas completed, however after regulatory review a magnetic compass is not required on this vessel on a LBS route.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 5 June 2019 Resolved
Provide permenant placards for lifejackets stowed in main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 6 June 2019
Resolution: New placards installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 June 2019 Resolved
Lable valves for CO2 system in bow thruster space.
Action required: 10 - Deficiency Rectified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Valves labled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2019 Resolved
Prove proper operation of stern light and range light.
Action required: 10 - Deficiency Rectified
Resolved 5 June 2019
Resolution: Lights working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2019 Resolved
Replace P/V valves on air recievers #2,#3, #4, and #5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 12 June 2019
Resolution: P/V valves replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 June 2019 Resolved
Replace pressure gauge on #2 air reciever.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 12 June 2019
Resolution: Pressure gauge replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 June 2019 Resolved
Submit for approval to MSC an as built electrical one line diagram.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2019
Resolution: submitted
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019 Resolved
Prove proper operation of time delay for generator space.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2019
Resolved 5 June 2019
Resolution: New time delay installed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 December 2018 Resolved
Replace the A/C and fire pump sea valves
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 April 2019
Resolution: New valves installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2018 Resolved
02 CO2 flex loops found craked and dry rotted on bow thruster fixed CO2 system. Replace 02 flex loops.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 August 2018
Resolution: 02 CO2 flex loops renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
Lable motor controller in bow thruster space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 August 2018
Resolution: Motor controller for bow thruser fan labled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2018 Resolved
Mount fire hose at fire station #11. Rotate valve as nessasary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 August 2018
Resolution: Fire hose station #11 properly mounted.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 April 2018 Resolved
Label each FM200 siren in the boiler room, engine room and generator room with " When Alarm Sounds Vacate at Once Clean Agent Being Released"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 16 April 2018
Engineering › Pressure Vessel › Relief Valve
Issued 9 April 2018 Resolved
Renew or replace pressure relief valve on ships horn air receiver located in the first class cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 April 2018 Resolved
Paint running light screens mat black
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 April 2018 Resolved
Repair e-light stbd side aft passenger deck
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 9 April 2018 Resolved
Demonstrate operation of low lube oil and high jacket water alarms and shut downs on OMNI thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 January 2018 Resolved
Starboard main had a number of exhaust leaks.
Due 18 February 2018
Resolved 23 January 2018
Resolution: Leaks repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 18 January 2018 Resolved
Prime mover for the #1 generator had an exhaust leak
Due 18 February 2018
Resolved 23 January 2018
Resolution: Leak repaired.
Engineering › Steam Boiler (auxiliary/waste heat) › Nozzle, Safety Valve
Issued 18 April 2016 Resolved
Safety relief valve set for 50 psig did not operate at 65 psig which is over the +10% allowed by regulation.
Due 21 May 2016
Resolved 2 June 2016
Fire Fighting › Fire Hydrants › Condition
Issued 18 April 2016 Resolved
#13 fire station hydrant was leaking
Due 21 May 2016
Resolved 2 June 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 April 2016 Resolved
Light fixture adjacent to the the grill hood was damaged and needs replacing
Due 21 May 2016
Resolved 2 June 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 18 April 2016 Resolved
Electrical cover on deli drink cooler compressor needs replacing
Due 21 May 2016
Resolved 2 June 2016
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 April 2016 Resolved
Stbd generator prime mover has an exhaust leak in stbd generator muffler void.
Due 21 May 2016
Resolved 2 June 2016
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 3 November 2015 Resolved
Repair leaks on port & starboard bow door rams. Wiper seals are leaking.
Due 1 July 2017
Resolved 2 June 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 3 November 2015 Resolved
Repair tachometer at anchor windlass.
Due 3 December 2015
Resolved 12 January 2016
Accommodation/Occupational Safety › Heating › Piping
Issued 3 November 2015 Resolved
Repair leaking circulating pump in first class cabin.
Due 3 December 2015
Resolved 1 December 2015
Resolution: Pump repaired.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 November 2015 Resolved
Repair FSD between galley and deli counter area.
Condition: Improper/Lack of Maintenance
Due 1 March 2016
Resolved 21 April 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 November 2015 Resolved
Install FSD in pass through between galley and deli counter area.
Condition: Improper Installation
Due 1 March 2016
Resolved 21 April 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 November 2015 Resolved
Repair leak on elevator lifting ram.
Condition: Improper/Lack of Maintenance
Due 3 July 2017
Resolved 6 July 2017
Resolution: Ram leak repaired.
Engineering › Steam System (auxiliary) › Valve, Relief
Issued 3 November 2015 Resolved
Replace pressure relief valve on furnace.
Due 10 November 2015
Resolved 10 November 2015
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 3 November 2015 Resolved
Repair indicator switch on #3 starboard WTD.
Condition: Improper/Lack of Maintenance
Due 3 December 2015
Resolved 1 December 2015
Resolution: Indicator repaired.
Engineering › Bilge Water Management System › Valve
Issued 3 November 2015 Resolved
Repair bilge suction reach rods in port shaft alley.
Condition: Improper/Lack of Maintenance
Due 3 December 2015
Resolved 1 December 2015
Resolution: Reach rod handles repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 August 2015 Resolved
Replace hoses on Bow Thruster CO2 system. The outer coating of the hoses was starting to fall off. Three hoses need to be replaced.
Due 6 September 2015
Resolved 3 November 2015
Resolution: Hoses replaced.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 6 August 2015 Resolved
Service embarcation side shell FWD door. Door is by Bow Thruster CO2 System. Door was painted shut.
Due 6 September 2015
Resolved 3 November 2015
Resolution: Door serviced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 August 2015 Resolved
Replace retro tape on life ring. Life ring is located on Upper deck Port side FWD.
Due 6 September 2015
Resolved 3 November 2015
Resolution: Retro replaced.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 August 2015 Resolved
Install life jacket placard on Upper decl life jacket lockers.
Due 6 September 2015
Resolved 3 November 2015
Resolution: Placard installed.
Construction/Loadline › Structures › Superstructure
Issued 6 August 2015 Resolved
Service latches on all sliding cabin doors in the main cabin. Door will not latch after they are closed.
Due 31 December 2015
Resolved 12 January 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 August 2015 Resolved
Label emergency lights. Noticed on car deck that all the emergency lights on the car deck were not labeled with an E.
Due 7 September 2015
Resolved 3 November 2015
Resolution: E-lights labeled.
Engineering › Bilge Water Management System › Valve
Issued 15 May 2014 Resolved
Install check valves in bilge main to prevent back flooding of spaces (fwd maninfold)
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 26 June 2017
Resolution: Check valves installed.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 15 May 2014 Resolved
Make proper repairs to rescue boat rub rails (port & stbd)
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 8 December 2014
Resolution: Vsl. rep. performed repairs on rescue boat.
Communications › Public Address System › Loudspeaker
Issued 15 May 2014 Resolved
Repair speakers in bar area.
Action required: 705 - Other - as specified
Due 3 August 2014
Resolved 11 September 2014
Resolution: Speakers tested sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2014 Resolved
Install bulb for stern light alarm panel.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 22 October 2014
Resolution: Bulb installed and tested.
Communications › Public Address System › Loudspeaker
Issued 15 May 2014 Resolved
Repair/install speakers on sun deck.
Action required: 705 - Other - as specified
Due 3 August 2014
Resolved 11 September 2014
Resolution: Resolved-decibel level is so high passengers are most likely not to sit in area during vent fan operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 15 May 2014 Resolved
Renew tubing on CO2 eng. room zone valve.
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 22 October 2014
Resolution: New high pressure line installed.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 15 May 2014 Resolved
Replace securing strap on rescue boat.
Action required: 705 - Other - as specified
Due 3 August 2014
Resolved 11 September 2014
Resolution: Securing strapped replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2014 Resolved
Replace broken glass on emergency fuel shut off.
Action required: 705 - Other - as specified
Due 3 August 2014
Resolved 11 September 2014
Resolution: Glass replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 May 2014 Resolved
Relabel emergency fuel shut offs.
Action required: 705 - Other - as specified
Due 3 August 2014
Resolved 11 September 2014
Resolution: Fuel shut offs labeled.
Fire Fighting › Fire Patrol › Two-Way Portable Radio
Issued 15 May 2014 Resolved
Provide fire watch in bow thruster space whenever bow thruster or hydraulic engine is running. Watch must be maintained until space CO2 system is fully operational and approved by an attending CG inspector.
Action required: 705 - Other - as specified
Resolved 24 July 2014
Resolution: MSC approved plans and CG MI verified installation.
Stability › Watertight Integrity › General
Issued 8 June 2012 Resolved
Remove doubler port side outboard IWO muffler space main deck.
Action required: 705 - Other - as specified
Due 2 August 2012
Resolved 5 July 2012
Fire Fighting › Means of Escape › Doorways
Issued 8 June 2012 Resolved
Stbd aft sliding door guide, reweld at bulkhead
Due 2 August 2012
Resolved 5 July 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 June 2012 Resolved
Repair stancions as discussed fwd 01 deck.
Due 2 August 2012
Resolved 5 July 2012
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 30 May 2012 Resolved
Identify and repair exhaust leaks in port exhaust void.
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 13 June 2012
Resolution: Flex couple was broken and has been replaced.
Engineering › Bilge Water Management System › Valve
Issued 30 May 2012 Resolved
Prove operation of screw down valve at collision bilkhead.
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 13 June 2012
Resolution: Proper operation of the valve was demonstrated.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 May 2012 Resolved
Prove operation of exit light illumination in cabin locations.
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 5 July 2012
Construction/Loadline › Structures › Door
Issued 30 May 2012 Resolved
Prove operation of latching plate on door, starboard side IWO galley.
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 13 June 2012
Resolution: Attended vessel, latch repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 May 2012 Resolved
Conduct credit drydock examination.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2012
Resolved 29 June 2012
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 28 September 2010 Resolved
Make repairs to oil leak on #1 SSDG between prime mover and generator.
Due 1 January 2011
Resolved 16 December 2010
Resolution: Vessel installed new generator, oil leak repair on install
Electrical › Electrical Distribution System (service) › Cable
Issued 28 September 2010 Resolved
Remove extension cord on port shaft sump pump.
Due 28 October 2010
Resolved 4 November 2010
Resolution: Attended vessel. Item corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 September 2010 Resolved
Provide 6 year service on dry chem ext #5
Due 28 October 2010
Resolved 4 November 2010
Resolution: Attended vessel. Item corrected.
Construction/Loadline › Structures › Door
Issued 28 September 2010 Resolved
Provide dog where missing at bottom of WTD, stbd side of pilot house.
Due 1 December 2010
Resolved 16 December 2010
Resolution: CG Inspector observed new dog.
Construction/Loadline › Structures › Door
Issued 28 September 2010 Resolved
Free up dogs on WTD to battery compartment.
Due 28 October 2010
Resolved 4 November 2010
Resolution: Attended vessel. Item corrected.
Accommodation/Occupational Safety › Potable Water System › General
Issued 28 September 2010 Resolved
Install pipe from relief valve on water heater to above deck in crew galley space.
Due 28 October 2010
Resolved 4 November 2010
Resolution: Attended vessel. Item corrected.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2010 Resolved
Install box patch in #4 void in accordance with propsed plan. Plan to address rounds of space for visual check for signs of leaking. Plan also to address last date of required service of vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 19 March 2010
Resolution: Box patch installed; plan provided.
Construction/Loadline › Hull › Side Shell
Issued 17 March 2010 Resolved
Crop and renew deck drain elbow in starboard forward ballast tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2010
Resolution: Elbow renewed.
Construction/Loadline › Hull › Side Shell
Issued 16 March 2010 Resolved
Make permanent repairs to the port side of the #4 void to the satisfaction of the attending marine inspector prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 17 March 2010
Resolution: Temporary repair proposal will be submitted for installtion of a box patch.
Construction/Loadline › Hull › Side Shell
Issued 16 March 2010 Resolved
Proceed directly to Thames Shipyard and contact a marine inspector rom Sector Long Island Sound prior to beginning any repairs.
Action required: 705 - Other - as specified
Resolved 17 March 2010
Resolution: Vessel arrived in New London, CT and a damage survey was conducted.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 January 2010 Resolved
Provide release for FSD #1 (Between main and aft passenger cabins). Door to release on activation of general alarm.
Due 9 June 2010
Resolved 24 June 2010
Resolution: Release installed and tested sat.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 January 2010 Resolved
Properly splice cable in pilothouse cabinet. Cable is located directly above the port cabinet in the middle of the space.
Due 9 June 2010
Resolved 24 June 2010
Resolution: Cable properly spliced.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 15 September 2008 Resolved
Make repairs to fuel oil transfer pump. (leaks)
Due 10 October 2008
Resolved 9 January 2009
Resolution: Leaks repaired.
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 15 September 2008 Resolved
Make repairs to STBD MDE tach generator. ( not indicating acutal speed)
Due 10 October 2008
Resolved 9 January 2009
Resolution: Shaft tachs replaced on both port and starboard MDEs.
Documentation › Certificates/Documents › Stability Letter
Issued 14 April 2008 Resolved
Provide updated stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2008
Resolution: Received call from MSC allowing the vessel to operate on it''s current stability letter.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 14 April 2008 Resolved
Secure refrigerator in crew galley.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Refrigerators secured.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 April 2008 Resolved
Relabel breaker panel in deli.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Breakers relabeled.
Construction/Loadline › Structures › Door
Issued 14 April 2008 Resolved
Prove watertight integrity of starboard #3 watertight door.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Door passed chalk test.
Construction/Loadline › Structures › Scuttle
Issued 14 April 2008 Resolved
Prove watertight integrity of port shaft alley emergency escape scuttle.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Scuttle tested and passed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 April 2008 Resolved
Make repairs to electrical outlet above BT-1 panel.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Outlet repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2008 Resolved
Repair light in aft steering.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Fixture needed replaced. Invoice provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2008 Resolved
Repair light in emergency escape alleyway.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Fixture needed replaced. Invoice provided.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 April 2008 Resolved
Provide covers for J-boxes in overhead of bar and concession stand.
Due 22 June 2008
Resolved 9 July 2008
Resolution: J-box covers provided.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2008 Resolved
Repair cage for light fiture in port shaft alley, aft.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Fixture needed replaced. Invoice provided.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 14 April 2008 Resolved
Provide metallic cable ties for all new electrical installations @ 24" intervals.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Metallic cable ties provided.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 14 April 2008 Resolved
Provide magnetic compass deviation card.
Due 22 June 2008
Resolved 9 July 2008
Resolution: Compass card provided.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 April 2008 Resolved
Update fire-safety plan.
Due 12 July 2008
Resolved 9 July 2008
Resolution: Duplicate entry.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 October 2007 Resolved
Prove operation of light in port fuel pump room void.
Due 5 October 2007
Resolved 3 October 2007
Resolution: Light repaired.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 2 October 2007 Resolved
Make reparis to excessive leaks on starboard generator to stop excessive leaking forward and aft.
Due 1 November 2007
Resolved 9 July 2008
Resolution: Engine overhauled/leaks repaired.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 September 2007 Resolved
Make repairs to emergency exit sign, crew lounge aft.
Due 5 October 2007
Resolved 3 October 2007
Resolution: Sign repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 September 2007 Resolved
Conduct 6 year maintenance on the following extinguishers. #2,3,4,6,8,9,11,17,13,19,20,25,26.
Due 5 October 2007
Resolved 3 October 2007
Resolution: Maintenance conducted.
Construction/Loadline › Structures › Door
Issued 20 September 2007 Resolved
Provide dogging wrench for port void of old diesel pump room void.
Due 5 October 2007
Resolved 3 October 2007
Resolution: Wrench provided.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Discharge Hose
Issued 20 September 2007 Resolved
Perform hydrostatic test of CO2 Hose and bottle for extinguisher in engine room.
Due 5 October 2007
Resolved 3 October 2007
Resolution: Bottle and hose are not required and removed from service.
Construction/Loadline › Structures › Door
Issued 20 September 2007 Resolved
Provide dogging wrench for bow thruster room IDWTD
Due 5 October 2007
Resolved 3 October 2007
Resolution: Wrench provided.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 September 2007 Resolved
Update safety plan in crew galley
Due 30 November 2009
Resolved 11 January 2010
Resolution: New plan displayed.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 May 2007 Resolved
Provide protective globe lense cover for emergency light in shaft alley athwart ship passway.
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 14 June 2007
Resolution: Protective globe provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2007 Resolved
provide metallic wire ties for cabling in furnance room.
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 20 June 2007
Resolution: Metallic wire ties installed.
Deck/Cargo › Holds/Tanks › Coaming
Issued 10 May 2007 Resolved
Repair/replace limit switch for #4 port watertight door.
Due 10 June 2007
Resolved 14 June 2007
Resolution: Limit switch repaired.
Communications › Alarms/Indicators › General Alarm
Issued 10 May 2007 Resolved
Stencil general alarm in machinery space.
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 14 June 2007
Resolution: General alarm stenciled.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 10 May 2007 Resolved
Repair/replace/remove air conditioning unit port side aft.
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 14 June 2007
Resolution: Air conditioner replaced.
Deck/Cargo › Holds/Tanks › Coaming
Issued 10 May 2007 Resolved
Provide dogging wrench for port aft engine room water tight door.
Condition: Improper/Lack of Maintenance
Due 3 June 2007
Resolved 14 June 2007
Resolution: Wrench provided.
Deck/Cargo › Holds/Tanks › Coaming
Issued 10 May 2007 Resolved
Prove watertight integrity of both aft engine room watertight doors.
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 2 October 2007
Resolution: Both E/R aft watertighting doors replaced and tested satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2007 Resolved
Clear overspray from running lights. (To be corrected prior to operating at night or reduced visability.)
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 14 June 2007
Resolution: Running lights cleaned.
Stability › Freeing Ports › General
Issued 10 May 2007 Resolved
Clear deck drains as marked by CG inspector.
Condition: Improper/Lack of Maintenance
Due 10 June 2007
Resolved 20 June 2007
Resolution: Clogged deck drain piping cropped and replaced with PVC.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 September 2006 Resolved
Provide smoke detectors for crew accomodation spaces.
Due 25 October 2006
Resolved 10 May 2007
Resolution: Smoke dectectors installed.
Stability › Watertight Integrity › General
Issued 15 September 2006 Resolved
Renew gasket and prove watertight seal for port aft emergency escape scuttle.
Due 15 October 2006
Resolved 10 May 2007
Resolution: Renewed gasket.
Stability › Watertight Integrity › General
Issued 15 September 2006 Resolved
Repair and prove watertight integtity of port and starboard aft engine room watertight door.
Due 15 October 2006
Resolved 19 September 2006
Resolution: Chalk test conducted - SAT
Communications › Internal Communications System › Portable Radios
Issued 15 September 2006 Resolved
Provide effective means of communication between wheel house and engine room.
Due 15 October 2006
Resolved 10 May 2007
Construction/Loadline › Structures › Door
Issued 19 May 2006 Resolved
Prove proper operation of #1 stbd WTD indicator.
Condition: Unknown
Due 20 June 2006
Resolved 20 June 2006
Resolution: Test sat.
Construction/Loadline › Structures › Door
Issued 19 May 2006 Resolved
Adjust #3 stbd WTD closure devices.
Condition: Improper/Lack of Maintenance
Due 20 June 2006
Resolved 20 June 2006
Resolution: Test sat.
Fire Fighting › Fire Main › Valves
Issued 19 May 2006 Resolved
Repair isolation valve @ #12 fire station.
Condition: Improper/Lack of Maintenance
Due 20 June 2006
Resolved 20 June 2006
Resolution: Test sat.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 19 May 2006 Resolved
Clean all gauge faces for hydraulic systems on vehicle deck.
Condition: Damaged By Earlier Event
Due 20 June 2006
Resolved 20 June 2006
Resolution: Gauges removed; not needed.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 19 May 2006 Resolved
Repair leak at gauge nipple on anchor hydraulic piping.
Condition: Unknown
Due 20 June 2006
Resolved 20 June 2006
Resolution: Test sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2006 Resolved
Repair lighting throughout vessel as needed (e.g. above capstan hyd., deck lighting, top of E/R escape trunk).
Condition: Improper/Lack of Maintenance
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Engineering › Bilge Water Management System › Strainer
Issued 19 May 2006 Resolved
Descale/muck out bilge suction area in port fwd shaft alley.
Condition: Improper/Lack of Maintenance
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 May 2006 Resolved
Install safety shields on bench grinder.
Condition: Improper Installation
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 19 May 2006 Resolved
Complete installation of exhaust pipe lagging on windlass hyd. engine.
Condition: Improper Installation
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Construction/Loadline › Structures › Door
Issued 19 May 2006 Resolved
Prove ease of operation of port fwd sliding door on passenger deck.
Condition: Improper/Lack of Maintenance
Due 20 June 2006
Resolved 20 June 2006
Resolution: Test sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 May 2006 Resolved
Install locking device on electrical distribution panel in passenger compartment iwo bathrooms.
Condition: Design Flaw
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 May 2006 Resolved
Provide mounting bracket for fire ext. in engine room.
Condition: Unknown
Due 20 June 2006
Resolved 20 June 2006
Resolution: Extra; removed from ship.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2006 Resolved
Paint background of navigation lights matte black.
Condition: Improper Installation
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 May 2006 Resolved
Service portable fire extinguishers #7 & 15.
Condition: Improper/Lack of Maintenance
Due 20 June 2006
Resolved 20 June 2006
Resolution: Complete.
Engineering › Steam Boiler (auxiliary/waste heat) › Tube Sheet
Issued 28 October 2005 Resolved
Vessel to conduct tests of heating boiler as required by 46 CFR 61.05-10.
Condition: Unknown
Due 15 November 2005
Resolved 18 April 2006
Resolution: Hydro, operation of relief & waterside completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 8 July 2005 Resolved
"Fuel oil to filter" gauge would not remain steady while in idle. Repair as needed.
Condition: Improper Installation
Due 8 August 2005
Resolved 19 July 2005
Resolution: 07/19/05: Fuel Oil to filter gauge on local panel for Port MDE TESTED SAT. [name withheld]
Construction/Loadline › Structures › Door
Issued 9 May 2005 Resolved
Make repairs to door between mid & aft passenger spaces.
Condition: Improper/Lack of Maintenance
Due 2 June 2005
Resolved 2 June 2005
Resolution: Completed.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 9 May 2005 Resolved
Secure all snack bar appliances.
Condition: Placed in Improper Service
Due 3 June 2005
Resolved 2 June 2005
Resolution: Completed.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 9 May 2005 Resolved
Provide updated compass deviation table.
Condition: Improper/Lack of Maintenance
Due 3 June 2005
Resolved 2 June 2005
Resolution: Completed.
Navigation › Piloting/Steering › Marine Charts
Issued 9 May 2005 Resolved
Provide corrected or new marine charts.
Condition: Improper/Lack of Maintenance
Due 3 June 2005
Resolved 2 June 2005
Resolution: Completed.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 May 2005 Resolved
Provide fire control plan as required by 46 CFR 78.45-1.
Condition: Unknown
Due 3 June 2005
Resolved 9 June 2005
Resolution: Completed.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 May 2005 Resolved
Repair light fixture sundeck port side.
Condition: Improper/Lack of Maintenance
Due 3 June 2005
Resolved 19 July 2005
Resolution: 07/19/05: Light Fixture on Port Sundeck has been repaired. [name withheld]
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 May 2005 Resolved
Reweld pipe bracket @ bow thruster engine seawater overboard.
Condition: Unknown
Due 3 June 2005
Resolved 2 June 2005
Resolution: Completed.
Engineering › Sea-water System (primary cooling) › Pump
Issued 9 May 2005 Resolved
Repair leaking seawater pump on anchor windlass hydraulics engine.
Condition: Improper/Lack of Maintenance
Due 3 June 2005
Resolved 2 June 2005
Resolution: Test sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 May 2005 Resolved
Repir junction box/install cover in vehicle deck overhead centerline forward.
Condition: Unknown
Due 3 June 2005
Resolved 2 June 2005
Resolution: Completed.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Replace missing deck drain screens as needed on passenger deck. LEGACY COMPONENT DESC: Scupper
Condition: Unknown
Due 17 January 2004
Resolved 4 June 2004
Resolution: Replaced
Accommodation/Occupational Safety › Ventilation
Issued 17 December 2003 Resolved
Replace missing galley hood vent filter screens (2). LEGACY COMPONENT DESC: Galley Range Hood
Condition: Unknown
Due 17 January 2004
Resolved 4 June 2004
Resolution: Replaced
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Crop & renew to good metal bow plating outboard port loading door. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 17 January 2004
Resolved 4 June 2004
Resolution: Repaired and tested.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Prove proper operation of exterior door to snack bar. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 17 January 2004
Resolved 4 June 2004
Resolution: Tested sat.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Level lap joints in deck IVO exterior door to snack bar (trip hazard). LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 17 January 2004
Resolved 4 June 2004
Resolution: Joint is faired.
Electrical › Electrical Distribution System (service)
Issued 17 December 2003 Resolved
Replace missing safety blanks in crew galley distribution panel. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Electrical › Electrical Distribution System (service)
Issued 17 December 2003 Resolved
Label hydraulic motor for bow door. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Prove proper operation of 02 deck door to crew space. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Electrical › Lighting (service)
Issued 17 December 2003 Resolved
Provide cover for rack light in 02 deck stateroom #2. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 17 January 2004
Resolved 4 June 2004
Resolution: Done
Pollution Prevention/Response › Prevention Equipment
Issued 17 December 2003 Resolved
Post MARPOL V placard in crew galley. LEGACY COMPONENT DESC: Garbage
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Engineering › Compressed Air System (control)
Issued 17 December 2003 Resolved
Replace pressure gauge on control air accumulator (port). LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper/Lack of Maintenance
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Electrical › Electrical Distribution System (service)
Issued 17 December 2003 Resolved
Install wire connection box in bow thruster room.
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Electrical › Electrical Distribution System (emergency)
Issued 17 December 2003 Resolved
Properly secure bow thruster battery box. LEGACY COMPONENT DESC: Battery Box
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Chalk test and adjust as needed port bow void door. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 17 January 2004
Resolved 4 June 2004
Resolution: Tested sat
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Install door dog clips on stbd bow void door. LEGACY COMPONENT DESC: Door
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Secure hatch wrench for pump void escape scuttle aft. LEGACY COMPONENT DESC: Trunk
Condition: Unknown
Due 17 January 2004
Resolved 21 May 2004
Resolution: Complete.
Construction/Loadline › Structures
Issued 17 December 2003 Resolved
Change access to bow thruster & vent as discussed. LEGACY COMPONENT DESC: Door
Condition: Design Flaw
Due 17 January 2004
Resolved 4 June 2004
Resolution: Done
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 May 2003 Resolved
Replace primary F/O line on the bow thruster eng. LEGACY COMPONENT DESC: F/O piping
Due 12 June 2003
Resolved 12 June 2003
Resolution: Cited new F/O line on the bow thruster eng.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 May 2003 Resolved
Replace L/O return line to the red gear on bow thruster eng. LEGACY COMPONENT DESC: L/O return line
Due 12 June 2003
Resolved 12 June 2003
Resolution: Witnessed replacement of L/O return line to the red gear on bow thruster eng.
Accommodation/Occupational Safety › Occupational Safety
Issued 8 May 2003 Resolved
Repair/reinforce deck grate in bow thruster room. LEGACY COMPONENT DESC: Deck grate
Due 12 June 2003
Resolved 12 June 2003
Resolution: Witnessed satisfactory test of deck grate in bow thruster room.
Electrical › Electric Supply System (service)
Issued 8 May 2003 Resolved
Properly secure battery box lid in bow thruster room. LEGACY COMPONENT DESC: Battery Installation
Due 12 June 2003
Resolved 12 June 2003
Resolution: Witnessed proper securing of battery box lid in bow thruster room.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 May 2003 Resolved
Make proper repairs to stbd shaft brake disc LEGACY COMPONENT DESC: Shaft disk
Due 12 June 2003
Resolved 24 June 2003
Resolution: Noted proper repairs made to stbd shaft brake disc
Engineering › Shafting/Propeller Arrangements
Issued 8 May 2003 Resolved
Open for inspection stbd clutch air receiver. LEGACY COMPONENT DESC: clutch air receiver
Due 12 June 2003
Resolved 12 June 2003
Resolution: Inspected stbd clutch air receiver.
Operations/Management › Pollution
Issued 8 May 2003 Resolved
Remove L/O from port muffler void. LEGACY COMPONENT DESC: Retention of Oily Mixture
Due 12 June 2003
Resolved 12 June 2003
Resolution: Witnessed L/O from port muffler void.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 May 2003 Resolved
Repair exhaust leaks in both muffler voids. LEGACY COMPONENT DESC: Air Silencer
Due 12 June 2003
Resolved 12 June 2003
Resolution: Cited repair of exhaust leaks in both muffler voids.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 May 2003 Resolved
Renew exhaust plentums port and strb muffler voids LEGACY COMPONENT DESC: Air Silencer
Due 12 June 2003
Resolved 12 June 2003
Resolution: Cited renewed exhaust plentums port and strb muffler voids.
Lifesaving › Lifejacket/PFD (General)
Issued 8 May 2003 Resolved
Provide life ring for strb fwd station. LEGACY COMPONENT DESC: Condition
Due 12 June 2003
Resolved 12 June 2003
Resolution: Cited life ring for strb fwd station.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 May 2003 Resolved
Hydro flex loop for CO2 system in the engine room. LEGACY COMPONENT DESC: Piping
Due 12 June 2003
Resolved 12 June 2003
Resolution: Witnessed hydro flex loop for CO2 system in the engine room.
Communications › Internal Communications System
Issued 8 May 2003 Resolved
Prove proper operation of EOT LEGACY COMPONENT DESC: Engine Order Telegraph System
Due 12 June 2003
Resolved 26 June 2003
Resolution: Observed proper operation of EOT
Communications › Alarms/Indicators
Issued 8 May 2003 Resolved
Prove proper operation of #3 strb WTD indicator. LEGACY COMPONENT DESC: Water Tight Door Indicator
Due 12 June 2003
Resolved 12 June 2003
Resolution: Cited proper operation of #3 strb WTD indicator.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 13 November 2002 Resolved
Prove proper operation of auxiliary heating boiler audible alarm. LEGACY COMPONENT DESC: Automation Equipment
Condition: Unknown
Due 12 December 2002
Resolved 12 May 2003
Resolution: Tested sat
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 November 2002 Resolved
Replace expired medications and missing bandages in first aid kits.
Condition: Improper/Lack of Maintenance
Due 12 December 2002
Resolved 13 November 2002
Engineering › Compressed Air System (control)
Issued 13 November 2002 Resolved
Prove proper operation of both clutch air receiver relief valves. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 12 December 2002
Resolved 12 May 2003
Resolution: Tested sat.
Accommodation/Occupational Safety › Ventilation
Issued 13 November 2002 Resolved
Replace 2 broken windows in crew space below pilot house. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Due 12 December 2002
Resolved 17 January 2003
Accommodation/Occupational Safety › Ventilation
Issued 13 November 2002 Resolved
Make proper repairs to natural vent port side void #3 ivo fire station #11. LEGACY COMPONENT DESC: Vent
Condition: Unknown
Due 12 December 2002
Resolved 17 January 2003
Fire Fighting › Fire Hoses
Issued 16 May 2002 Resolved
Replace 75' hose so that all hoses have the same tread. LEGACY COMPONENT DESC: Connections
Due 17 June 2002
Resolved 13 November 2002
Resolution: Hose replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 May 2002 Resolved
Free up the center fan shut down located in the starboard shaft alley control station. LEGACY COMPONENT DESC: Operating Controls
Due 17 June 2002
Resolved 13 November 2002
Resolution: Repair complete.
Accommodation/Occupational Safety › Ventilation
Issued 16 May 2002 Resolved
Replace starboard bridge window, second one foward of the wing door LEGACY COMPONENT DESC: Bridge window
Due 17 June 2002
Resolved 13 November 2002
Resolution: Window replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 May 2002 Resolved
Tie down snack bar equipment, waste cans, and newspaper machines.
Due 17 June 2002
Resolved 13 November 2002
Construction/Loadline
Issued 12 April 2001 Resolved
Replace bilge wrapper in starboard CHT compartment
Condition: Unknown
Due 30 January 2002
Resolved 8 April 2002
Construction/Loadline
Issued 3 October 2000 Resolved
Re-adjust both individualy dogged doors in Stb shaft alley.
Condition: Unknown
Due 31 December 2000
Resolved 3 October 2000
Fire Fighting
Issued 3 October 2000 Resolved
Permanetly secure CO2 cable runs in Stbd shaft alley.
Condition: Unknown
Due 10 October 2000
Resolved 3 October 2000
Electrical
Issued 3 October 2000 Resolved
Repair electrical panel door on car deck and engine room lighting panel.
Condition: Unknown
Due 31 December 2000
Resolved 11 January 2002
Electrical
Issued 31 May 2000 Resolved
Replace wire mesh in natural vent opening in emg. battery room.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Electrical
Issued 31 May 2000 Resolved
Provide proper circuit label for panelboard in emergency battery room.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Electrical
Issued 31 May 2000 Resolved
Repair cable supports for wire runs above panel boards #1 & 2 in gen room.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Navigation
Issued 31 May 2000 Resolved
Prove proper operation of port EOT
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 31 May 2000 Resolved
Adjust and prove tightness of watertight door #3 Port.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Accommodation/Occupational Safety
Issued 31 May 2000 Resolved
Provid exit signs for crew niche.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Lifesaving
Issued 31 May 2000 Resolved
Provide ladder for port rescue boat station.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 31 May 2000 Resolved
Remove excessive mud from way of fore peak bilge suction.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Electrical
Issued 31 May 2000 Resolved
replace panel front for panel board in boiler room.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 31 May 2000 Resolved
Provide reach rods for bilge manifold in bow thurster space.
Condition: Unknown
Due 28 February 2001
Resolved 31 May 2000
Fire Fighting
Issued 31 May 2000 Resolved
provide fire plan
Condition: Unknown
Due 30 June 2000
Resolved 8 April 2002
Lifesaving
Issued 24 May 2000 Resolved
Provide ladder for port rescue boat station.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Accommodation/Occupational Safety
Issued 24 May 2000 Resolved
provied exit signs for crew niche.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 24 May 2000 Resolved
Provide fire plan
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Navigation
Issued 24 May 2000 Resolved
Prove proper operation of Port EOT.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
Adjust and prove tightness of watertight door #3 Port.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
Remov excessive mud from way of Fore Peak bilge suction.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Electrical
Issued 24 May 2000 Resolved
Replace panel front for panel board in boiler room.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Electrical
Issued 24 May 2000 Resolved
Provide proper circuit label for panelboard in emergency battery room.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Electrical
Issued 24 May 2000 Resolved
Repair cable supports for wire runs above panel boards #1 & 2 in gen room.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Electrical
Issued 24 May 2000 Resolved
Replace wire mesh in natural vent opening @ Emg. Battery room.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Construction/Loadline
Issued 24 May 2000 Resolved
provide reach rods for bilge manifold in bow thurster space.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Navigation
Issued 8 September 1999 Resolved
PROPERLY LABLE SPP DIAL LOCATION ON THE PORT CAR DECK.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999 Resolved
REPAIR OR REPLACE THE BROKEN LIGHT FIXTURES ON THE CAR DECK.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Engineering
Issued 8 September 1999 Resolved
PROVE PROPER OPERATION OF THE LOW OIL LEVEL ALARMS AT NEXT OIL CHANGE.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Engineering
Issued 8 September 1999 Resolved
DEMONSTRATE PROPER OPERATION OF THE MDE'S CRANKCASE PRESSURE SWITCH TRIP AND ALARM.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Engineering
Issued 8 September 1999 Resolved
CONDUCT TEST OF ALL ALARMS AND FUNCTIONS FOR THE HOT WATER HEATING BOILER.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999 Resolved
PROPERLY SECURE COFFEE POT IN SNACK BAR.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999 Resolved
REMOVE DEAD-ENDED WIRES AND STUFF BULKHEAD FITTINGS IN OLD WHEELHOUSE.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 13 May 1999 Resolved
PROVIDE WIRE CLIPS EVERY 24' FOR WIRE LOCATED STBD SIDE UPPER CREW CABIN OUTBOARD.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Electrical
Issued 13 May 1999 Resolved
REPAIR OR REPLACE RACK LIGHT IN [name withheld].
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
INSTALL A PROPER PIPE HANGER FOR CO2 PIPING OVER SMALL HYDRAULIC DIESEL - BOW THRUSTER ROOM.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Electrical
Issued 13 May 1999 Resolved
REMOVE EXTENSION CORDS IN WAY OF MICROWAVE, MAIN CASH REGISTER, BAR CASH REGISTER.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Construction/Loadline
Issued 13 May 1999 Resolved
INSTALL STRAINER FOR BILGE PIPE IN BOW TRUSTER ROOM.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Navigation
Issued 13 May 1999 Resolved
PROVE PROPER OPERATION OF THE PHASE FAILURE ALARMS FOR BOTH STEERING GEAR MOTORS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
REPLACE TUBING TO VENT PRESSURE SWITCHES USING HIGH PRESSURE TUBING.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Construction/Loadline
Issued 13 May 1999 Resolved
INSTALL A REACH ROD FOR BILGE MANIFOLD - OLD DIESEL PUMP ROOM.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Construction/Loadline
Issued 13 May 1999 Resolved
RE-FIR HATCH COVER ON MAIN DECK AS DISCUSSED.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
REPLACE ALL CORRODED PIPING ON BOW THRUSTER CO2 SYSTEM OR PRESSURE TEST. PIPING SHALL BE A53/A106 GALVANIZED SEAMLESS. TYPE "F" IS PROHIBITED.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Lifesaving
Issued 13 May 1999 Resolved
LABEL GENERAL ALARMS LOCATED IN GAME ROOM AND CREW'S LAUNDRY.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Construction/Loadline
Issued 13 May 1999 Resolved
PROVIDE 2 DOGGING WRENCHES FOR THE EMERGENCY ESCAPE DOOR IN GALLEY.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
REPLACE RUPTURE DISC AND RELIEF VALVE ON PIPING SYSTEM.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 13 May 1999 Resolved
INSTALL END OF THE LINE DIRT TRAPS FOR CO2 SYSTEM IN BOW THRUSTER.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Electrical
Issued 13 May 1999 Resolved
PROVIDE PLAN FOR EMERGENCY BATTERY SYSTEM SHOWING REQUIRED VOLTAGE ON SYSTEM.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Electrical
Issued 13 May 1999 Resolved
PROVIDE VISIBLE INDICATOR IN THE MACHINERY SPACE TO SHOW COMPLIANCE WITH 46CFR 112.45.
Condition: Unknown
Due 13 June 1999
Resolved 27 May 1999
Fire Fighting
Issued 14 December 1998 Resolved
MAKE BULKHEADS BETWEEN STATEROOMS BI5 IAW STRUCTURAL FIRE PROTECTION.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Electrical
Issued 14 December 1998 Resolved
PROVE PROPER OPERATION OF THE LOW L/O TRIPS ON BOTH S/S DIESEL GENERATORS.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 14 December 1998 Resolved
REPAIR OR REPLACE THE PORT SIDE ENGINE ROOM'S AFT WTD INDICATOR SWITCH.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Electrical
Issued 14 December 1998 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIPS FOR BOTH S/S DIESEL GENERATORS.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Electrical
Issued 14 December 1998 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHTS IN THE PASSENGER CABINS.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 2 October 1998 Resolved
PROVIDE POSITIVE MEANS OF CLOSURES FOR VENTS ON THE MAIN DECK.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Electrical
Issued 2 October 1998 Resolved
REMOVE DEAD-ENDED WIRES ON PORT BRIDGE WING.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 2 October 1998 Resolved
PROPERLY LAG THE BOILER EXHAUST STACK.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Construction/Loadline
Issued 2 October 1998 Resolved
PROPERLY SECURE MAN HOLE COVER, STBD SIDE BALLAST TANK.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Accommodation/Occupational Safety
Issued 2 October 1998 Resolved
PROVE PROPER OPERATION OF THE PORT FWD DOOR LEADING OUT FROM THE BAR.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Lifesaving
Issued 2 October 1998 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON PORT FWD LIFE RING.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Construction/Loadline
Issued 2 October 1998 Resolved
PROPERLY CAP THE PIPE PENETRATION IN THE BATTERY ROOM.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 2 October 1998 Resolved
REMOVE ALL OF THE PAINT CANS STORED IN THE BOILER ROOM.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 2 October 1998 Resolved
PROPERLY LAG ALL OF THE HOT WATER HEATING PIPING THRU-OUT THE VESSEL.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Lifesaving
Issued 2 October 1998 Resolved
PROVIDE AND POST INSTRUCTIONS FOR LIFEJACKETS AND LIFE RAFTS.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 13 August 1997 Resolved
Remove lagging for CG inspection of main enginnnne exhaust risers on main deck. Install new lagging so temperature on main deck is cool to the touch.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 29 May 1997 Resolved
Provide piping specs and plans for air start system.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Lifesaving
Issued 20 May 1997 Resolved
REPAIR WINCH FOR STBD RESCUE BOAT. DEMONSTRATE PROPER OPERATION OF STBD BOAT DAVIT & WINCH. (N.B. WIRE ROPE WOUND ON THE WRONG DIRECTION.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Electrical
Issued 20 May 1997 Resolved
REPLACE MISSING LAMP GLOBES ON AFT END OF PORT VEHICLE DECK.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Electrical
Issued 20 May 1997 Resolved
REPAIR & PROVE OPERATION OF BATTERY POWERED EMERGENCY LIGHT ON FWD BHD OF PASSENGER LOUNGE.
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Fire Fighting
Issued 20 May 1997 Resolved
RENEW PIPING FOR VEHICLE DECK SPRINKLER SYSTEM.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 26 June 1996 Resolved
PROVIDE EMERGENCY LIGHTS AT FORWARD ENGINE ROOM WATERTIGHT BULKHEADS
Condition: Unknown
Due 30 August 1996
Resolved 30 August 1996
Lifesaving
Issued 26 June 1996 Resolved
PROVODE PIPING SPECS AND PLANS FOR AIR START SYSTEM
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Unknown
Issued 26 June 1996 Resolved
PERFORM FIRE AND EMERGENCY DRILLS IN PRESENCE OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Navigation
Issued 26 June 1996 Resolved
PROVIDE COMPASS DEVIATION TABLE AND CHART
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Electrical
Issued 26 June 1996 Resolved
REMOVE ELECTRICAL ANTENNA WIRING INTO VENT ON 02 DECK
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Navigation
Issued 26 June 1996 Resolved
LABEL RUDDER ANGLE INDICATOR IN STEERING ROOM SO IT CAN BE SEEN FROM PHONE AND HAND PUMP
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Lifesaving
Issued 26 June 1996 Resolved
LABEL ENGINE ROOM ESCAPES ON VEHICLE DECK
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Electrical
Issued 26 June 1996 Resolved
PROVIDE COVERS ON BATTERIES IN BATTERY ROOM
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Navigation
Issued 26 June 1996 Resolved
REPAIR RANGE LIGHT ALARMS
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Lifesaving
Issued 26 June 1996 Resolved
PROVIDE 8" STEPS ON BOTH SIDES OF NEWLY INSTALLED WATERTIGHT DOORS.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Lifesaving
Issued 26 June 1996 Resolved
PROVIDE GUARD ON LOWER AIR COMPRESSOR BELTS
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Construction/Loadline
Issued 26 June 1996 Resolved
REPAIR OR REMOVE BILGE ALARM SYSTEM PANEL
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Unknown
Issued 26 June 1996 Resolved
LABEL MAIN ENGINE ALARMS AND INSTRUMENTATION
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Lifesaving
Issued 26 June 1996 Resolved
PROVID AND OPERATIONALLY TEST RELIEF VALVE FOR FOGHORN AIR RECIEVER
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 26 June 1996 Resolved
LABEL WATERTIGHT DOOR INDICATOR SWITCHES
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Navigation
Issued 26 June 1996 Resolved
REPAIR ENGINE ROOM STEERING REMOTE CONTROL SYSTEM
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Lifesaving
Issued 26 June 1996 Resolved
PRIMARY LIFESAVING AND PASSENGER MEASUREMENT TO BE COMPLETED PRIOR TO INCREASE IN PASSENGERS.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Navigation
Issued 26 June 1996 Resolved
PROVIDE DOCUMENTATION OF PLAN APPROVAL FOR CHANGE IN STEERING CONTROL SYSTEM
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Electrical
Issued 24 August 1995 Resolved
PROPERLY MOUNT ALL CABLES THROUGHOUT VESSEL.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 24 August 1995 Resolved
RENEW GASKET FOR STEERING FLAT ACCESS HATCH, PORT SIDE STERN.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 24 August 1995 Resolved
REPLACE MISSING FIRE EXTINGUISHER AT STATION #15 (IWO BOW THRUSTER)
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 24 August 1995 Resolved
BLANK OFF OVERBOARD AT HULL, PORT SIDE SPACE AFT OF BOW THRUSTER MACHINERY SPACE.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
REHANG CABLES PRESENTLY ATTACHED TO PIPING, BOW THRUSTER MACHINARY SPACE.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Engineering
Issued 24 August 1995 Resolved
RELAG MUFFLER IN BOW THRUSTER ROOM.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 24 August 1995 Resolved
MARK FIRE EXTINGUISHER STATION BOW THRUSTER ROOM.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 24 August 1995 Resolved
PROVIDE CORRECT SPANNER WRENCH FOR FIRE STATION #1.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
REMOVE DEAD END WIRES IN [name withheld].
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 24 August 1995 Resolved
REPLACE DEFECTIVE PFDS: 79 ADULT / 19 CHILDREN
Condition: Unknown
Due 8 September 1995
Resolved 11 October 1995
Documentation
Issued 24 August 1995 Resolved
CONDUCT AND LOG WEEKLY FIRE AND BOAT DRILLS.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
REPLACE ALL MISSING GLOBES ON LIGHTS AS NEEDED THROUGHOUT VESSEL.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
PROPERLY BLANK OFF HOLES IN JUNCTION BOX IN CREW LOUNGE.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 24 August 1995 Resolved
DURING WEEK OF 05SEP95, REMOVE LIFEJACKETS FOR INSPECTION AND ACCOUNTABILITY.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
PROVIDE LIGHT COVER AND BULB IN ENGINEER'S ROOM.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
PROVIDE LIGHT FIXTURE IN OLD RADAR ROOM
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 24 August 1995 Resolved
PROVIDE HANDLE FOR PFD STOWAGE BOX, UPPER DECK STBD, AFT, WITH CAPACITY OF 108.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 24 August 1995 Resolved
REMOVE PAINT FROM AFT DECK LOCKER, UPPER DECK, OR PROVIDE PROPER PAINT LOCKER.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 24 August 1995 Resolved
FIX FIRE EXTINGUISHER BRACKET IN BAR, OVER STBD SIDE REAR.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 24 August 1995 Resolved
CONDUCT TEST OF SPRINKLER SYSTEM ON CAR DECK DURING THE WEEK OF 05SEP95
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Lifesaving
Issued 24 August 1995 Resolved
CONDUCT TEST OF RESCUE BOAT
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Navigation
Issued 24 August 1995 Resolved
REPAIR BULBS IN ALARM PANEL FOR NAVIGATION LIGHTS.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Engineering
Issued 24 August 1995 Resolved
PROVIDE HAND RELIEFS FOR TWO RELIEF VALVES FOR STARTING AIR.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 24 August 1995 Resolved
REPAIR FRACTURE TO SPRINKLER SYSTEM PIPING.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Construction/Loadline
Issued 24 August 1995 Resolved
RE-WELD FRACTURED WELDS IWO DECK ATWARTSHIP SUPPORTS FOR CAR DECK NEAR ENGINE ROOM ENTRANCE IN STEERING FLAT.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
BLANK-OFF MISSING BREAKER IN #1 PANEL IN E/R
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
PROVIDE NON-CONDUCTIVE MAT IWO GENERATOR SWITCHBOARD
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Fire Fighting
Issued 24 August 1995 Resolved
RE-CONNECT BLANKED-OFF 100LB BOTTLE IN E/R CO2 SYSTEM.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
REPLACE, AND SECURE SUPPORT FOR, EMERGENCY LIGHT IN CREW LOUNGE.
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Electrical
Issued 24 August 1995 Resolved
RENEW JUNCTION BOX OR REMOVE DEAD WIRES ON MISSING JUNCTION BOX IN OVERHEADABOVE CAR DECK (ABOUT 1/3 BACK FROM BOW).
Condition: Unknown
Due 20 October 1995
Resolved 20 October 1995
Construction/Loadline
Issued 17 June 1993 Resolved
ADJUST SHAFT ALLEY WATERTIGHT DOORS (4) TO ENSURE PROPER CLOSING.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Lifesaving
Issued 17 June 1993 Resolved
PUMP AND CLEAN ENGINE ROOM BILGES.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Construction/Loadline
Issued 9 May 1991 Resolved
RENEW GASKETS IN ALL PORT AND STBD SHAFT ALLEY WATERTIGHT DOORS.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Navigation
Issued 23 May 1990 Resolved
PROVIDE GENERAL ALARM RED FLASHING LIGHT OF SUFFICIENT INTENSITY IN ENGINEROOM TO BE ACTIVATED WHEN GENERAL ALARM BELLS IN ENGINEROOM ARE ACTIVATED.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Lifesaving
Issued 23 May 1990 Resolved
PROVIDE EMBARKATION LIGHTS OFF EMERGENCY POWER CIRCUIT AT PORT AND STARBOARD LIFERAFT STATIONS.
Condition: Unknown
Due 23 May 1990
Resolved 23 May 1990
Construction/Loadline
Issued 16 July 1987 Resolved
REPAIR MAJOR COLLISION DAMAGE TO PORT BOW DOOR AND STRUCTURE
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Construction/Loadline
Issued 10 May 1985 Resolved
VEE AND WELD CRACKED BULKHEAD IN #2 STBD VOID
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Construction/Loadline
Issued 10 May 1985 Resolved
WELD 3 BULKHEAD STIFFNERS BROKEN AWAY FROM FWD BULKHEAD IN #2 PORT VOID
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Construction/Loadline
Issued 10 May 1985 Resolved
REMOVE OILY SLOPS FROM #3 STBD VOID
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Engineering
Issued 10 May 1985 Resolved
PROVIDE BRACKETS ON FUEL LINES RUNNING THROUGH #5,6,7,8,AND 9 VOIDS
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Engineering
Issued 10 May 1985 Resolved
MAKE BULKHEAD PENETRATIONS FOR FUEL LINES IN VOIDS #5,6,7,8, AND 9 WATERTIGHT
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Fire Fighting
Issued 10 May 1985 Resolved
CONDUCT SATISFACTORY FIRE AND BOAT DRILL
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Engineering
Issued 10 May 1985 Resolved
CLEAN OUT BILGE SUCTIONS IN #1 PORT AND STBD WING BALLAST TANKS
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Engineering
Issued 10 May 1985 Resolved
PROVIDE STRAINERS ON BILGE SUCTIONS IN #2 PORT AND STBD, #3 PORT AND STBD, #5, AND #8 VOIDS
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985

Casualty record · 11

7 July 2008Routine · role: Involved in a Marine Casualty · activity 3289015
7 August 2008Routine · role: Involved in a Marine Casualty · activity 3317479
15 March 2010Routine · role: Involved in a Marine Casualty · activity 3698070
3 January 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4540180
27 November 2013Routine · role: Subject to Marine Inspection · serious marine incident, as classified · 1 injured · activity 4762146
12 October 2015Routine · role: Involved in a Marine Casualty · activity 5743422
14 October 2017Routine · role: Involved in a Marine Casualty · 1 injured · activity 6327591
30 October 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6573332
30 May 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7389565
20 February 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7400753
18 September 2024Routine · role: Involved in a Marine Casualty · activity 8012601
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.