Records from 2008 to 2026. Most recent: inspection, 12 May 2026.
Inspection history · 46
12 May 2026
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8354887
1 April 2026
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8343444
21 January 2026
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8299550
13 August 2025
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8212683
14 May 2025
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8133100
31 January 2025
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8070214
18 September 2024
Deficiency Check · Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8005247
18 September 2024
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8012601
29 August 2024
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7992292
20 June 2024
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7932350
15 April 2024
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7896292
26 January 2024
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7856372
25 October 2023
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7814644
26 July 2023
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7751965
24 June 2023
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7863301
20 April 2023
COI Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7654279
9 January 2023
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7618340
24 August 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7536070
16 May 2022
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7453202
27 April 2022
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7419850
20 February 2022
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7400753
9 February 2022
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7392553
23 December 2021
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7371967
8 September 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7306463
30 May 2021
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7389565
12 May 2021
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7179050
10 February 2021
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7138492
2 November 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7087000
27 May 2020
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6957814
6 April 2020
Special Consideration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6935948
10 January 2020
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6885840
21 October 2019
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6837136
12 June 2019
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6712214
14 December 2018
MTSA Verification · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6597963
30 October 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6573332
31 July 2018
Deficiency Check · Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6496796
9 April 2018
MTSA Verification · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6388271
18 January 2018
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6341685
14 October 2017
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6327591
31 March 2017
COI Inspection · Deadweight Survey · Hull Examination · Internal Structural Exam · MTSA Verification · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6117068
14 October 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6022311
28 July 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5955791
2 June 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5895375
18 April 2016
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5856781
1 April 2016
Re-Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5847906
12 January 2016
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5795835
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 May 2026
Resolved
Fire main plug on the port side car deck found with a 1" hole. Renew valve.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2026
Resolved 13 May 2026
Resolution: New valve spool piece installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2025
Resolved
A-class door in-between galley to deli doesn’t shut
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Door fixed, all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025
Resolved
Missing two bilge strainers, fuel tank void & ballast tank
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Strainers installed, all sat
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2025
Resolved
Replace high level bilge alarm in fuel tank void
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Replaced, all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 May 2025
Resolved
Numerous emergency lighting was inop (crew exit sign, 8 on car deck, P & S shaft alley, bow thruster, E/R, gen space, stbd maindeck aft exit)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Lighting replaced, all sat
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 May 2025
Resolved
Low water alarm in the boiler is inop
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 19 May 2025
Resolution: Replaced switch, all sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2024
Resolved
A survey shall be made every time an accident occurs which affects the saftey of the vessel. Repair port shaft and propeller as in-kind. Vessel is restricted from carrying passengers until proper repair has been verified by a marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2024
Resolution: New shaft has been installed and aligned. Prop installed. Operational test conducted. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 September 2024
Resolved
A survey shall be made every time an accident occurs which affects the saftey of the vessel. Due to the failure of the port shaft that resulted in the prop breaking off, an inspection of the starboard shaft and propeller is to be made to ensure integrity and prevent a similar occurance.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2024
Resolution: Witnessed NDT, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2024
Resolved
Flexible CO2 hoses on bow thruster system dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 June 2024
Resolved
05 Sprinkler heads on the car deck blocked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 June 2024
Resolved
MI's observed 02 E lights on the car deck not working.
Action required: 10 - Deficiency Rectified
Due 20 June 2024
Resolved 20 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 20 June 2024
Resolved
General alarm bells not stenicled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2024
Resolved 27 June 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2020
Resolved
Prove proper operation of generator room FM200 system.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2020
Resolved 28 May 2020
Resolution: FM200 bottle recharged and installed.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 May 2020
Resolved
Provide watertight door indicator light for WTD #4.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 27 May 2020
Resolution: Light bulb was replaced for the door and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2020
Resolved
Proved machanical interlock for main switch board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 28 May 2020
Resolution: Interlock re-installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2020
Resolved
Provide sight glass guard on port fuel tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2020
Resolved 28 May 2020
Resolution: Guard installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2020
Resolved
Provide new lifebuoy.
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 28 May 2020
Resolution: New lifebouy replaced on the spot
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 October 2019
Resolved
Complete compass deviation test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 27 May 2020
Resolution: Devaiationwas completed, however after regulatory review a magnetic compass is not required on this vessel on a LBS route.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 5 June 2019
Resolved
Provide permenant placards for lifejackets stowed in main cabin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 6 June 2019
Resolution: New placards installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 June 2019
Resolved
Lable valves for CO2 system in bow thruster space.
Action required: 10 - Deficiency Rectified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Valves labled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 June 2019
Resolved
Prove proper operation of stern light and range light.
Action required: 10 - Deficiency Rectified
Resolved 5 June 2019
Resolution: Lights working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2019
Resolved
Replace P/V valves on air recievers #2,#3, #4, and #5.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 12 June 2019
Resolution: P/V valves replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 June 2019
Resolved
Replace pressure gauge on #2 air reciever.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 12 June 2019
Resolution: Pressure gauge replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 June 2019
Resolved
Submit for approval to MSC an as built electrical one line diagram.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 July 2019
Resolution: submitted
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2019
Resolved
Prove proper operation of time delay for generator space.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2019
Resolved 5 June 2019
Resolution: New time delay installed and tested sat.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 December 2018
Resolved
Replace the A/C and fire pump sea valves
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 April 2019
Resolution: New valves installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2018
Resolved
02 CO2 flex loops found craked and dry rotted on bow thruster fixed CO2 system. Replace 02 flex loops.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 August 2018
Resolution: 02 CO2 flex loops renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018
Resolved
Lable motor controller in bow thruster space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 August 2018
Resolution: Motor controller for bow thruser fan labled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2018
Resolved
Mount fire hose at fire station #11. Rotate valve as nessasary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 August 2018
Resolution: Fire hose station #11 properly mounted.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 April 2018
Resolved
Label each FM200 siren in the boiler room, engine room and generator room with " When Alarm Sounds Vacate at Once Clean Agent Being Released"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 16 April 2018
Engineering › Pressure Vessel › Relief Valve
Issued 9 April 2018
Resolved
Renew or replace pressure relief valve on ships horn air receiver located in the first class cabin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 April 2018
Resolved
Paint running light screens mat black
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 April 2018
Resolved
Repair e-light stbd side aft passenger deck
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 9 April 2018
Resolved
Demonstrate operation of low lube oil and high jacket water alarms and shut downs on OMNI thruster.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 1 May 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 18 January 2018
Resolved
Starboard main had a number of exhaust leaks.
Due 18 February 2018
Resolved 23 January 2018
Resolution: Leaks repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 18 January 2018
Resolved
Prime mover for the #1 generator had an exhaust leak
Due 18 February 2018
Resolved 23 January 2018
Resolution: Leak repaired.
Engineering › Steam Boiler (auxiliary/waste heat) › Nozzle, Safety Valve
Issued 18 April 2016
Resolved
Safety relief valve set for 50 psig did not operate at 65 psig which is over the +10% allowed by regulation.
Due 21 May 2016
Resolved 2 June 2016
Fire Fighting › Fire Hydrants › Condition
Issued 18 April 2016
Resolved
#13 fire station hydrant was leaking
Due 21 May 2016
Resolved 2 June 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 April 2016
Resolved
Light fixture adjacent to the the grill hood was damaged and needs replacing
Due 21 May 2016
Resolved 2 June 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 18 April 2016
Resolved
Electrical cover on deli drink cooler compressor needs replacing
Due 21 May 2016
Resolved 2 June 2016
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 April 2016
Resolved
Stbd generator prime mover has an exhaust leak in stbd generator muffler void.
Due 21 May 2016
Resolved 2 June 2016