Records from 1990 to 2025. Most recent: inspection, 14 November 2025.
Inspection history · 109
14 November 2025
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8268552
16 April 2025
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8123257
22 October 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8020403
10 September 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7054907
20 May 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6688357
26 March 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6649431
25 January 2019
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6614977
7 November 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6576317
21 September 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6544151
19 September 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6544048
11 September 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6537695
22 March 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6376762
29 December 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6335583
13 November 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6305712
5 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6281758
11 April 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6122152
20 March 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6108431
27 February 2017
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6095273
3 January 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6064955
17 November 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6042912
12 October 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6020777
23 February 2016
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5820362
14 October 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5742268
24 October 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5015068
9 June 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4884210
20 June 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4350778
20 June 2012
Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4351161
16 March 2010
Construction Oversight · COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3634107
19 March 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3436706
19 March 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3436715
19 March 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3436720
19 March 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3436722
26 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3248631
15 January 2008
Administrative Inspection · Hull Examination · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3130845
10 September 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3055899
5 September 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3051831
10 July 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2991276
10 July 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2991277
2 May 2007
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2920824
25 April 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2921274
20 April 2007
COI Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2911450
14 February 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2910789
19 January 2007
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2888577
25 July 2006
Deficiency Check · MTSA/ISPS Verification · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2724081
21 June 2006
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2687140
16 June 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2687066
16 June 2006
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2757475
17 February 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2587033
14 December 2005
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2551299
16 September 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2493910
14 July 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2426437
14 July 2005
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2426903
5 May 2005
MTSA Verification · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2349726
13 April 2004
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2043294
25 March 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2143435
12 February 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2005251
14 July 2003
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1846178
16 May 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1796511
1 April 2003
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1766341
19 August 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663178
14 June 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1632121
24 April 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1608632
14 February 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1486433
20 April 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1063018
11 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1450604
14 July 2000
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1446961
1 June 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1404989
18 May 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361490
25 April 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1435025
9 February 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1391213
13 May 1999
Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 879924
16 December 1998
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807621
7 July 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 168249
19 May 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126533
9 March 1998
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1120140
26 January 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 774930
23 September 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778427
22 July 1997
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 781221
11 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1110443
10 December 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097670
28 October 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 160724
24 June 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085658
23 May 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1180994
5 March 1996
Deficiency Check · Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886216
1 March 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 91263
24 January 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189730
25 August 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877170
17 July 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1360183
11 July 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1079234
28 June 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1193728
23 May 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1188172
16 May 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1188171
12 May 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 185359
9 June 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1324478
25 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 864069
22 January 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 852634
6 December 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 672682
3 August 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1152318
21 July 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153234
1 June 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 841310
27 March 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 831936
13 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 10555
5 June 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1255192
12 December 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 947155
10 December 1991
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 944403
28 June 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 938816
6 July 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909430
6 July 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 932151
22 June 1990
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1219099
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 16 April 2025
Resolved
Vessel had an expired impulse-projected rocket type line throwing appliance. Replace with a new line throwing appliance approved under 46CFR160.040
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2025
Resolution: Received a picture
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 16 April 2025
Resolved
Compass requires callibration and new deviation card. Have compass swung and a new deviation card issued.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 14 November 2025
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 November 2018
Resolution: While running a query in VIVS, the IMO number for the vessel had been updated and AIS was broadcasting the proper information.
Engineering › Freshwater System (jacketwater cooling) › Filling Line
Issued 22 March 2018
Resolved
#2 SSDG expansion tank was leaking coolant and the was hot to the touch.
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 18 April 2018
Resolution: Vessel rep replaced in kind the heat exchanger, expansion tank cap, and temperature gauge. Vessel rep proved operation by running generator under load and engine remained at 180 degrees.
Engineering › Freshwater System (jacketwater cooling) › Filling Line
Issued 22 March 2018
Resolved
#1 SSDG water pump was leaking. Repair/renew
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 5 April 2018
Stability › Watertight Integrity › General
Issued 22 March 2018
Resolved
Hatch covers above each engine was leaking. Make watertight at next DDX.
Action required: 705 - Other - as specified
Due 31 March 2019
Resolved 22 May 2019
Resolution: Deck hatches sealed with rubber gasket, silicone and a layer of bituthene, all sat.
Stability › Watertight Integrity › General
Issued 22 March 2018
Resolved
Deck hatch in tank room was not watertight. Make water tight.
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 5 April 2018
Lifesaving › Inflatable Liferafts › Servicing
Issued 13 November 2017
Resolved
THE VESSEL'S 25-PERSON INFLATABLE LIFE RAFT HAS BEEN REMOVED FOR ANNUAL SERVICING AND REPLACED WITH A 20-PERSON RAFT. TOTAL PERSONS ALLOWED ON BOARD IS LIMITED TO 76 UNTIL THE 25-PERSON LIFE RAFT IS RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 1 December 2017
Resolution: Verified the 25-person liferaft has been re-installed on the port side. All SAT.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 5 October 2017
Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 26 October 2017
Resolution: IBA installed correctly.
Lifesaving › Inflatable Liferafts › Servicing
Issued 17 November 2016
Resolved
The vessel's 25-person life raft has been removed for annual servicing. Total persons allowed on board is reduced to 56 until the life raft has been re-installed to the satisfaction of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 28 November 2016
Resolution: Inspected the instalation of one 25-person life raft, all sat.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 12 October 2016
Resolved
THE VESSEL'S 50-PERSON INFLATABLE BUOYANT APPARATUS HAS BEEN REMOVED FOR SERVICING. TOTAL PERSONS ALLOWED ON BOARD IS LIMITED TO 25 UNTIL THE IBA IS REINSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 November 2016
Resolved 28 October 2016
Resolution: Verified proper hydrostatic release hook-up, painter, and service record on container.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 February 2016
Resolved
05 stitch welds on port aft of lazarette and 02 fillet welds on stbd side are cracked.
46 CFR 176.25-5(a) (OLD T)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 10 March 2016
Resolution: Welds were repaired to the satisfaction of the attending Coast Guard Marine Inspector
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 14 October 2015
Resolved
THE VESSEL'S 50-PERSON IBA HAS BEEN REMOVED FOR ANNUAL SERVICING. PASSENGER CAPACITY IS LIMITED TO 21 PLUS 4 CREW UNTIL THE IBA HAS BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 27 October 2015
Resolution: IBA reinstalled - sat.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 14 October 2015
Resolved
THE VESSEL'S 25-PERSON IBA HAS BEEN REMOVED FOR ANNUAL SERVICING. PASSENGER CAPACITY IS LIMITED TO 47 PLUS 3 CREW UNTIL THE IBA HAS BEEN RE-INSTALLED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 November 2015
Resolved 13 November 2015
Resolution: Reinstalled - sat.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 24 October 2014
Resolved
Vessel has removed 25 man life raft for servicing; passenger capacity has been reduced to 50 until raft has been serviced and placed back onboard and inspected by CG Marine Inspector.
Action required: 705 - Other - as specified
Due 7 November 2014
Resolved 4 November 2014
Resolution: Life raft has been serviced and re-installed. All Sat.
Engineering › Fuel Oil Service System › Piping
Issued 9 June 2014
Resolved
Small fuel leak on aft generator. Make repairs.
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 23 June 2014
Resolution: Installed new approved fuel line, tested with satisfactory results.
Engineering › Lubricating Oil Service System › Piping
Issued 9 June 2014
Resolved
Hydraulic hose valves for steering have seized valves in the open position. Repair/replace.
Action required: 705 - Other - as specified
Due 23 June 2014
Resolved 23 June 2014
Resolution: Actuated valves with satisfactory results.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 20 June 2012
Resolved
Replace all contaminated fuel water seperator filters and conduct sea trial.
Action required: 705 - Other - as specified
Due 20 June 2012
Resolved 21 June 2012
Resolution: All filters replaced and engines running as normal sea trial conducted sat.
Engineering › Steering Gear System › Piping
Issued 26 June 2008
Resolved
Replace wasted hydraulic piping and fasteners to steering rams
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 March 2009
Resolution: completed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 June 2008
Resolved
Replace or repair mounting bracket for extinguisher located on aft bulkhead of pilot house.
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 31 March 2009
Resolution: complete.
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 January 2008
Resolved
Vessel may not carry passenger until vessel is haul for out of water post grounding survey
Action required: 705 - Other - as specified
Due 3 March 2008
Resolved 3 March 2008
Resolution: Vessel was hauled and repaired at Roses Marine Gloucester, Ma
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2007
Resolved
Replace expired items in First Aid kit.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Switch
Issued 20 April 2007
Resolved
Install cover on stbd spot light 110volt switch box.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 23 April 2007
Resolution: Corrected
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 April 2007
Resolved
Repair rudder angle indicator.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 April 2007
Resolved
Reapair E-light in engine room.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 20 April 2007
Resolved
Repair dislodged furnace exhaust pipe; cover electrical box; mount hanging electrical control module; install missing insulation on door.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Stability › Weathertight Integrity › General
Issued 20 April 2007
Resolved
Install 3 missing dogs on stbd sliding side door.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 31 March 2009
Resolution: complete.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 April 2007
Resolved
Repair power available lights for both generators.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 23 April 2007
Resolution: Corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2007
Resolved
Provide diffusers for stbd and port forward engine room florescent lights.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Communications › Audible Communications › Bell
Issued 20 April 2007
Resolved
Provide proper size bell IAW Nav Rules.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 20 April 2007
Resolved
Make pressure vessel available for credit internal/external inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2007
Resolved 23 April 2007
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 20 April 2007
Resolved
Repair lube oil leak on inboard side of port outboard engine IWO filter housing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2007
Resolved 23 April 2007
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 20 April 2007
Resolved
Tighten.renew clam on injector fuel line, stbd inboard engine.
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 31 May 2007
Resolution: Corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 April 2007
Resolved
Provide current service on all portable extinguishers. Current inspection expires 30 Apr.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 23 April 2007
Resolution: Corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 20 April 2007
Resolved
Renew mounting bracket for galley extinguisher.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 23 April 2007
Resolution: Corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2007
Resolved
Renew one forward and one aft ring buoy (2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2007
Resolved 23 April 2007
Resolution: Corrected
Lifesaving › Visual Distress Signals (General) › Expired
Issued 20 July 2006
Resolved
Dispose of and replace with three new orange smoke distress signals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 27 July 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 July 2006
Resolved
Replace with updated, outdated and missing Nav. pubs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 27 July 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 July 2006
Resolved
Properly mount all portable fire extinguishers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 27 July 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 20 July 2006
Resolved
Replace missing light globes on the main deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 27 July 2006
Engineering › Generator (propulsion-electric) › Ground Detection Equipment Circuitry
Issued 20 July 2006
Resolved
Prove proper operation of the ground detection system. Previous deficiency.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 27 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 16 June 2006
Resolved
Make permanet repairs to damage to sideshell tear located IWO #2 and #3 void spaces.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2006
Resolved 21 June 2006
Resolution: 30" X 7'''' Insert installed in starboard forward sideshell above the waterline.
Construction/Loadline › Hull › Hull Plating
Issued 16 June 2006
Resolved
Make permanent repair to the damage side shell tear located in way of watertight bulkhead between #2 and #3 void space starboard.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2006
Resolved 27 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 February 2006
Resolved
Renew water intake hose for starboard main engine line.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 9 March 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 17 February 2006
Resolved
Reweld #2 frame located in the #6 void space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 9 March 2006
Construction/Loadline › Structures › Manhole
Issued 17 February 2006
Resolved
Attach captive chains for lazerette and #3 void space manhole hatch covers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 9 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 12 December 2005
Resolved
Make permanent repairs to 3" hole above the water line aft port side 6" from transom.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 December 2005
Resolved 9 January 2006
Resolution: Repairs made sat.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 14 July 2005
Resolved
Make permanent repairs to stbd/fwd strut. Repairs must be hose tested prior to installation of gussets.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 27 July 2005
Resolution: Repairs made
Construction/Loadline › Hull › Bottom Plating
Issued 14 July 2005
Resolved
Crop and renew hull bottom plating IWO 4 inch crack found near 1st longitudinal stiffener to stbd of keel in No. 6 void. Must be hose tested.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 27 July 2005
Resolution: Repairs made
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 July 2005
Resolved
Repair cracks on stbd/inboard longitudinal deep frame IWO aft transverse frame in No. 6 void.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 27 July 2005
Resolution: Repairs made
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 July 2005
Resolved
Repair crack weld on 1st longitudinal stiffener to port of keel in No. 6 void.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 27 July 2005
Resolution: Repairs made
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 5 May 2005
Resolved
Provide local release instructions for engine room halon system.
Due 5 June 2005
Resolved 6 June 2005
Resolution: Provided local release instructions.
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 5 May 2005
Resolved
Provide instructions/line diagram for installed fire/bilge system.
Due 5 June 2005
Resolved 6 June 2005
Resolution: Provided.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 5 May 2005
Resolved
Properly fill out emergency broadcast placard.
Due 5 June 2005
Resolved 6 June 2005
Resolution: Properly filled out broadcast placard.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 5 May 2005
Resolved
Properly repair and prove proper operation of ground detection system.
Due 5 July 2005
Resolved 27 July 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 May 2005
Resolved
Proved passenger capacity placard for 01 and 02 level.
Due 5 June 2005
Resolved 5 May 2005
Resolution: Re-installed placards.
Navigation › Collision/Grounding Avoidance
Issued 16 May 2003
Resolved
Properly repair the port running light shield. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 20 June 2003
Construction/Loadline › Markings
Issued 16 May 2003
Resolved
Properly label the draftmarks, fore and aft on the vessel. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 20 June 2003
Engineering › Bilge Water Management System
Issued 16 May 2003
Resolved
Properly label the bilge manifold with the compartment I.D. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 20 June 2003
Electrical › Electric Supply System (service)
Issued 16 May 2003
Resolved
Properly install a junction box and remove the wire nuts to the stern light. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 20 June 2003
Navigation › Piloting/Steering
Issued 16 May 2003
Resolved
Provide chart 13272. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 20 June 2003
Construction/Loadline › Structures
Issued 24 April 2002
Resolved
Renew gaskets on watertight deck hatches for forepeak, #2 void and lazarette, and prove watertight integrity of each hatch. LEGACY COMPONENT DESC: Scuttle
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 14 May 2002
Resolution: Witnessed satisfactory chalk and hose testing of all affected watertight closures.
Construction/Loadline › Penetrations › Weld
Issued 14 February 2002
Resolved
Repair port rudder post thru hull castings.
Due 19 February 2002
Resolved 19 February 2002
Resolution: Recoated pitted areas on port rudder post castings.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 February 2002
Resolved
Renew fuel supply hoses on port after main engine.
Due 19 February 2002
Resolved 19 February 2002
Resolution: Renewed fuel supply hose for port after main engine.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 February 2002
Resolved
Renew fuel supply hose for stbd after main engine.
Due 19 February 2002
Resolved 19 February 2002
Resolution: Renewed fuel supply hose for stbd main engine.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 February 2002
Resolved
Reweld two broken deck plate brackets in the center of the engine room.
Due 19 February 2002
Resolved 19 February 2002
Resolution: Rewelded two broken brackets for deck plates in the engine room.
Engineering › Bilge Water Management System
Issued 14 February 2002
Resolved
Double clamp hose intake line for PTO pump off after port main engine.
Due 19 February 2002
Resolved 19 February 2002
Construction/Loadline › Hull
Issued 14 February 2002
Resolved
Reweld pulled away frames as marked in the number #2, #3, #4, and lazarette compartments.
Due 19 February 2002
Resolved 19 February 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 14 February 2002
Resolved
Tighten leaking union in supply piping located next to storage.
Due 19 February 2002
Resolved 19 February 2002
Construction/Loadline
Issued 11 April 2001
Resolved
PROVE PROPER OPERATION OF BILGE ALARM (AUDIO) NLT 20APR01, TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Fire Fighting
Issued 11 April 2001
Resolved
PROVIDE PROPER OPERATING INSTRUCTIONS POSTED AT FIXED FIRE FIGHTING OPERATING LOCATION.
Condition: Unknown
Due 11 April 2001
Resolved 17 April 2001
Lifesaving
Issued 18 May 2000
Resolved
Replace the sea painters for all life floats.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Lifesaving
Issued 18 May 2000
Resolved
Remove oil from engine room bilge.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Documentation
Issued 18 May 2000
Resolved
Provide and post radiotelephony certification.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Accommodation/Occupational Safety
Issued 18 May 2000
Resolved
Properly install furnace door.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 18 May 2000
Resolved
Properly install insulation on both doors to main deck furnace space.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 18 May 2000
Resolved
Replace lanyards on manhole covers for lazarette and forepeak.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Electrical
Issued 18 May 2000
Resolved
Properly install plugs on mounting boxes for aft yellow lights and fwd portyellow light.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Lifesaving
Issued 18 May 2000
Resolved
Provide 3 water lights for life floats.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Electrical
Issued 18 May 2000
Resolved
Properly install junction box cover for main deck furnace.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 9 February 2000
Resolved
SUBMIT PLANS FOR AND MAKE PERMENANT REPAIRS TO THE SIDE SHELL IWO VOID NUMBER FOUR, STBD SIDE AFT, JUST FORWARD OF THE WATERTIGHT BULKHEAD, ONE FOOT BELOW THE MAIN DECK. REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Fire Fighting
Issued 13 May 1999
Resolved
PROVIDE A-60 INSULATION FOR FURNACE ROOM.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 13 May 1999
Resolved
PROVIDE AND POST MARPOL PLACARDS.
Condition: Unknown
Due 5 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 13 May 1999
Resolved
CROP AND RENEW BENT/TWISTED FRAMES AS MARKED IN #2 VOID AND AFTER LAZARETTE.
Condition: Unknown
Due 5 June 1999
Resolved 22 June 1999
Lifesaving
Issued 13 May 1999
Resolved
INSTALL DETACHABLE CLIP FOR RING BUOY WATER LIGHT.
Condition: Unknown
Due 5 June 1999
Resolved 21 June 1999
Electrical
Issued 13 May 1999
Resolved
RENEW ALL MISSING LIGHT COVERS IN ENGINE ROOM.
Condition: Unknown
Due 5 June 1999
Resolved 21 June 1999
Deck/Cargo
Issued 13 May 1999
Resolved
CROP AND RENEW WASTED/HOLED SEWAGE LINE IN WAY OF FORWARD BULKHEAD IN AFTERLAZARETTE.
Condition: Unknown
Due 5 June 1999
Resolved 21 June 1999
Documentation
Issued 13 May 1999
Resolved
PROVIDE AND POST CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 5 June 1999
Resolved 21 June 1999
Documentation
Issued 13 May 1999
Resolved
PROVIDE AND POST RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 5 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 19 May 1998
Resolved
REPAIR BROKEN WELD AS MARKED IN LAZARETTE STBD SIDE.
Condition: Unknown
Due 20 May 1998
Resolved 28 May 1998
Engineering
Issued 19 May 1998
Resolved
REPAIR EXHAUST LAGGING ON PORT OUTBOARD MDE.
Condition: Unknown
Due 20 May 1998
Resolved 28 May 1998
Construction/Loadline
Issued 19 May 1998
Resolved
REPAIR THE TWO BROKEN WELDS IN THE 2ND VOID AS MARKED.
Condition: Unknown
Due 20 May 1998
Resolved 28 May 1998
Electrical
Issued 11 June 1997
Resolved
REPAIR PORT AND STARBOARD LIGHTING FIXTURES ON MAIN DECK FANTAIL.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Fire Fighting
Issued 11 June 1997
Resolved
REPLACE AND PROVE PROPER OPERATION OF FIRE PUMP DISCHARGE PRESSURE GUAGE.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Electrical
Issued 11 June 1997
Resolved
REPAIR ALL SPLICES IN THE PA ANNOUNCING SYSTEM. BAD SPLICES LOCATED WITHIN10" OF ALL SPEAKERS.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Accommodation/Occupational Safety
Issued 11 June 1997
Resolved
REPLACE COVER FOR THERMOSTAT LOCATED BY BY AFT STARBOARD LOADING DOOR.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Construction/Loadline
Issued 11 June 1997
Resolved
REPLACE MISSING DOG ON FORWARD BOTTOM OF AFT STARBOARD LOADING DOOR.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Engineering
Issued 11 June 1997
Resolved
REPAIR EXHAUST LEAK ON STARBOARD FORWARD MDE.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Construction/Loadline
Issued 11 June 1997
Resolved
CROP AND RENEW 1RST, 2ND, AND 3RDE TRIPPING BRACKETS ON STARBOARD SIDE AFT IN LAZARETTE. (COUNTING FROM TOP TO BOTTOM). REPAIR BROKEN WELDS AS MARKED.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Construction/Loadline
Issued 11 June 1997
Resolved
PROVIDE DRAFT MARKINGS FORE AND AFT PRIOR TO CONCLUSION OF NEXT DRYDOCK.
Condition: Unknown
Due 11 June 1997
Resolved 11 June 1997
Electrical
Issued 11 June 1997
Resolved
REPAIR BROKEN LIGHTING FIXTURE ON MAIN DECK FOC'STLE STARBOARD SIDE.
Condition: Unknown
Due 20 June 1997
Resolved 25 July 1997
Electrical
Issued 23 May 1996
Resolved
PRIOR TO OPERATION OF #2 SHIP SERVICE GENERATOR, SECURE FUEL LEAK AT FUEL PUMP.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Fire Fighting
Issued 23 May 1996
Resolved
COMPLETE PERMENENT REPAIRS TO FIXED HALON SYSTEM AND COMPLETE TESTING ON BOARD TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR. POST WARNING SIGNS AT OPERATOR STATION AND PULL STATION INDICATING SYSTEM IS OUT OF ORDER UNTIL REPAIRS COMPLETED.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Electrical
Issued 23 May 1996
Resolved
RENEW ELECTRICAL PANEL DOOR LATCH TO 208/120 VOLT AC PANEL IN ENGINE ROOM.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Lifesaving
Issued 23 May 1996
Resolved
REPLACE LIFE FLOAT PADDLES WHERE WASTED.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 23 May 1996
Resolved
RENEW MAIN DECK PORTSIDE WINDOW AFT WHERE BROKEN.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Accommodation/Occupational Safety
Issued 23 May 1996
Resolved
PROVIDE SERVICE REPORT FOR HOT AIR FURNACE AND CONDUCT BURNER SAFETY SHUTDOWNS IN PRESENCE OF CG MARINE INSPECTOR PRIOR TO OPERATION OF FURNACE.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996
Construction/Loadline
Issued 5 March 1996
Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN COMPARTMENT NO. 6 IN WAY OF BOTH THEPORT AND STARBOARD FORWARD-MOST BOTTOM TRANSVERSE FRAMES AND OUTBOARD BOTTOM LONGITUDINALS (BOTH SIDES).
Condition: Unknown
Due 15 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 5 March 1996
Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN COMPARTMENT NO. 7: BOTH PORT AND STARBOARD SIDES IN WAY OF THE BOTTOM-FORWARD TRANSVERSE FRAME AND OUTBOARD LONGITUDINALS.
Condition: Unknown
Due 15 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 5 March 1996
Resolved
MAKE PERMANENT REPAIRS TO FRACTURE IN COMPARTMENT NO. 2 IN WAY OF #3 BOTTOMTRANSVERSE FRAME NEAR CENTER VERTICAL KEEL.
Condition: Unknown
Due 15 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 5 March 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, CROP OUT AND RENEW AS ORIGINAL, TRANSVERSE FRAME AFT OF STARBOARD INBOARD ENGINE.
Condition: Unknown
Due 15 March 1996
Resolved 22 March 1996
Engineering
Issued 5 March 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, MAKE PERMANENT REPAIRS TO STARBOARD FORWARD TRANSMISSION AND SHAFT.
Condition: Unknown
Due 15 March 1996
Resolved 22 March 1996
Engineering
Issued 5 March 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ALL MAIN ENGINES AND PROPULSION EQUIPMENT WHILE UNDERWAY.
Condition: Unknown
Due 15 March 1996
Resolved 22 March 1996
Construction/Loadline
Issued 24 January 1996
Resolved
REPAIRED 6 BROKEN WELDS IN COMPARTMENTS 5 & 6 IN WAY OF BOTTOM LONG TO FRAME ATTACHMENT
Condition: Unknown
Due 24 January 1996
Resolved 26 January 1996
Engineering
Issued 24 January 1996
Resolved
RENEWED HOLED EXHAUST PIPE ELBOW TO PORT FORWARD MAIN ENGINE.
Condition: Unknown
Due 24 January 1996
Resolved 26 January 1996
Construction/Loadline
Issued 11 July 1995
Resolved
VEE-OUT AND REWELD FRACTURES IN COMPARTMENT NO. 6 AS IDENTIFIED AND MARKED (8 TOTAL ON AFT TRANSVERSE FRAME) BY 01 AUG 95._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 July 1995
Resolved 11 July 1995
Construction/Loadline
Issued 28 June 1995
Resolved
VEE-OUT AND REWELD FRACTURES IN COMPARTMENT NO. 6 AS IDENTIFIED AND MARKED (12 TOTAL) BY 07 JULY 1995.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Engineering
Issued 28 June 1995
Resolved
PLACE LAGGING ON STARBOARD SIDE, FORWARD MOST MAIN EXHAUST PIPING, NO LATERTHAN 07 JULY 1995.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Unknown
Issued 28 June 1995
Resolved
MAKE USER FEE PAYMENT AND PROVIDE PROOF OF SUCH TO INSPECTIONS DEPARTMENT NO LATER THAN 30 JUNE 1995.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Construction/Loadline
Issued 23 May 1995
Resolved
RE-WELD FRACTURED WELD IN #6 COMPARTMENT STARBOARD SIDE, 1ST FRAME FORWARD OF THE AFT BULKHEAD.
Condition: Unknown
Due 6 June 1995
Resolved 7 July 1995
Construction/Loadline
Issued 23 May 1995
Resolved
RE-WELD FRACTURED WELDS ON PORT AND STARBOARD SIDES OF THE LAZARETTE AT THESTEERING RAM MOUNT PLATE, FORWARD SIDE.
Condition: Unknown
Due 6 June 1995
Resolved 7 July 1995
Unknown
Issued 23 May 1995
Resolved
RE-PAINT DRAFT MARKS ON THE PORT SIDE OF THE VESSEL.
Condition: Unknown
Due 6 June 1995
Resolved 7 July 1995
Accommodation/Occupational Safety
Issued 23 May 1995
Resolved
RENEW FRACTURED WINDOW ON THE PORT SIDE OF THE PILOT HOUSE (SLIDING WINDOW)._x001C_
Condition: Unknown
Due 6 June 1995
Resolved 7 July 1995
Engineering
Issued 23 May 1995
Resolved
REPALCE (REINSTALL) EXHAUST INSULATION PADS ON THE STARBOARD FORWARD AND PORT AFT MAIN ENGINE EXHAUSTS.
Condition: Unknown
Due 6 June 1995
Resolved 7 July 1995
Lifesaving
Issued 23 May 1995
Resolved
REPLACE AND RESTENCIL WITH ESSEL'S NAME, THE LIFE FLOAT PADDLES THAT HAVE OPEN SEAMS ON PADDLE END.
Condition: Unknown
Due 6 June 1995
Resolved 7 July 1995
Navigation
Issued 23 May 1995
Resolved
PROVER PROPER OPERATION OF THE INSTALLED PORT RADAR.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Construction/Loadline
Issued 25 May 1994
Resolved
GRIND DOWN, VEE OUT, AND REWELD FRACTURED WELDS IN #6 VOID SPACE AS MARKED (TOTAL OF 14 FRACTURED WELDS IN ALL).
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Lifesaving
Issued 25 May 1994
Resolved
PROVIDE/REPLACE SIX PADDLES FOR LIFEFLOATS.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 22 January 1994
Resolved
PRIOR TO PLACING VESSEL BACK IN SERVICE REPLACE 2 1/2" BALL VALVE ON FIRE/BILGE PUMP.
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Engineering
Issued 22 January 1994
Resolved
PRIOR TO PLACING VESSEL BACK IN SERVICE REPLACE PORT OUTBOARD PROPELLER.
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Lifesaving
Issued 1 June 1993
Resolved
PROVIDE A COAST GUARD APPROVED WATERLIGHT FOR THE #3 STARBOARD LIFEFLOAT INACCORDANCE WITH 46 CFR 180.15-5.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Electrical
Issued 1 June 1993
Resolved
REPLACE COVER ON 12 VOLT EMERGENCY BATTERY RACK LOCATED ON TOP OF THE PILOTHOUSE.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 1 June 1993
Resolved
PRIOR TO OPERATING MORE THAN 1000 FEET FROM SHORE, PROVIDE A VALID FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Construction/Loadline
Issued 1 June 1993
Resolved
MAKE WATERTIGHT THE PIPING RUN LOCATED IN COMPARTMENT 3 AT FRAME 10 PORT SIDE OF THE TRANSVERSE WATERTIGHT BULKHEAD.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Lifesaving
Issued 1 June 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 1 June 1993
Resolved
PRIOR TO OPERATION, PROVIDE A CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Engineering
Issued 1 June 1993
Resolved
MAKE THE PRESSURE VESSEL IN THE ENGINE ROOM AVAILABLE FOR EITHER INTERNAL EXAMINATION OR HYDROSTATIC TESTING TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Construction/Loadline
Issued 1 June 1993
Resolved
ON OR BEFORE NEXT DRYDOCK, RENEW ALL FRACTURED WELDS IN COMPARTMENT #6 ALONG FRAMES 30 AND 31 WHERE THEY INTERSECT THE FLOOR STRINGERS TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Documentation
Issued 22 June 1990
Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE AND POST THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990