MAURY USCG vessel records
← All vessels

JACQUELYN YVONNE

JACQUELYN YVONNE is a 1943 towing vessel. The Coast Guard has recorded 23 inspections since 1998, most recently in June 2025, along with 31 deficiencies and 1 casualty investigation in 2023.

Records from 1998 to 2025. Most recent: inspection, 26 June 2025.

Built
1943
Last inspected
26 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WCZ9679
352512
Flag
UNITED STATES
Maury page id
psix-352512

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded4
Years with a record 14 calendar years (1998–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)45.2 ft × 12.8 ft × 7.7 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTURGEON BAY SHIPBUILDING & DRYDOCK · built 1943
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMUSKEGON, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
29 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WILLIAM C GAYNOR Towing Vessel · MISLE 72405 · 15 April 2023 · activity 7674759DONALD J. SARTER Towing Vessel · MISLE 84819 · 15 April 2023 · activity 7674759CAMERON O Towing Vessel · MISLE 133441 · 15 April 2023 · activity 7674759USS CLEVELAND (LCS 31) Public Vessel, Unclassified · MISLE 1619775 · 15 April 2023 · activity 7674759

Inspection history · 23

26 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8168649
12 July 2024 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7956822
1 June 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7736132
15 April 2023 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7674759
2 September 2022 Hull Examination · Administrative Inspection · Examination of Repairs · Excursion Permit · Damage Survey · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7561109
1 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7522554
9 June 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7472643
12 January 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7379289
15 July 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7263813
25 June 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7003094
22 April 2019 Initial Certification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6719866
12 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6505539
22 September 2017 Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6274881
10 April 2012 Industry Initiated Exam · MTSA Verification
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4284727
14 March 2012 Administration
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 4263258
29 December 2006 Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2847775
31 May 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2666289
25 October 2005 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2522367
18 August 2005 Uninspected Other
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2466930
2 February 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999971
9 February 1998 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 753068
4 February 1998 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 11100
4 February 1998 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 195148

Deficiency record · 31

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 26 June 2025 Resolved
Each towing vessel operating north of lat. 32° N. or south of lat. 32° S. must carry the number of immersion suits as prescribed in this paragraph. Each towing vessel operating in those regions must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person onboard. 01 immersion suit on board was out of service. Replace immersion suit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2025
Resolution: Verified new immersion suit was onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 June 2025 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Vessel's company is alternating vessel platforms each month for the required monthly drills, instead of conducting one for each vessel. Complete fire drill prior to towing operations for this vessel and continue doing so monthly.
Action required: 705 - Other - as specified
Resolved 11 August 2025
Resolution: Verified shipboard drills were conducted and logged.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 26 June 2025 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel electronic charts out of date. Update electronic charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2025
Resolution: Chart system was updated.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2024 Resolved
Fire detection over main engine was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2024
Resolution: New heat detector installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2024 Resolved
Fire control panel is displaying a trouble alarm for the inoperable detector. Ensure no other alarm condition exists once new detector is installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2024
Resolved 5 September 2024
Resolution: Fire detection panel is no longer exhibiting a trouble indication.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2024 Resolved
Semi-portable CO2 bottles outside of engine room space missed annual servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 September 2024
Resolution: Van's fire servicing provided servicing for semi-portable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2024 Resolved
01 RLB was found wasted.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2024
Resolved 15 August 2024
Resolution: RLB was replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2024 Resolved
Vessel did not have a hose available for the fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2024
Resolved 15 August 2024
Resolution: New hose available. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2024 Resolved
Exposed wiring was found on the aft section of the wheelhouse presenting a shock hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2024
Resolved 15 August 2024
Resolution: Wiring reconnected to fixture. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 July 2024 Resolved
Watertight door gaskets need to be repaired/replaced. STBD side - missing gasket, Engine room hatch- dry rot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 15 August 2024
Resolution: Gaskets renewed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 July 2024 Resolved
The seal where the superstructure meets the deck can be seen from the engine room and is found to show substantial corrosion allowing daylight to come through to engine room. Ensure boundary to engine room maintains watertight integrity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 5 September 2024
Resolution: Caulking was installed to the satisfaction of the attending MI to ensure watertightness under normal operating condition.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 June 2023 Resolved
EPIRB Battery expired, renew 406 EPIRB Battery as required by 46 CFR 141.380 To be resolved on or before July 1st 2023.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 13 June 2023
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 September 2022 Resolved
Cut, crop and renew area of wasted bottom hull plating above the propeller and rudder, and renew the rudder tube as required by 46 CFR 137.300(b).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 7 October 2022
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 9 June 2022 Resolved
Company required to provide evidence that vessels annual CG inspection users fee were paid. IAW 46 CFR 2.10-101
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 23 June 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 June 2022 Resolved
Records unavailable CG MI attendance. Company required logbooks and other missing logs or documentation reflecting crew training and inspections conducted iaw 46 CFR 140.905 and 140.405
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 23 June 2022
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 July 2021 Resolved
Observed bilge alarm missing. Not installed as required by 46 CFR 143.230(a)(5). O/O required to install, with CG MI to re-attend and verify installation before 23AUG2021.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 23 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 July 2021 Resolved
Observed flammable stowage locker not properly secured. O/O required to properly secure the flammable locker as required by 46 CFR 142.225. CG MI to re-attend and verify installation before 23AUG2021
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 23 August 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 May 2019 Resolved
Company failed to fully fill out forms as required by companies Towing Vessel Record (TVR) Subchapter Compliance Management System (Maritime Compliance International, LLC Publication). Complete as applicable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 May 2019 Resolved
Towing vessels Official Logbook, lacks history of usage. Master are to fill out and company to provide history of usage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 May 2019 Resolved
Renew all expired items in the first aid kit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 May 2019 Resolved
Renew lights on all lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2019 Resolved
Install a second life ring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 May 2019 Resolved
EPIRB registration expired, renew.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 28 May 2019 Resolved
All six Port light covers were missing, renew and install.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 May 2019 Resolved
Two 50lb CO2 cylinders & hose installed in the engine room. Relocate both cylinders and hose outside engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 May 2019 Resolved
Renew and retest the main engine high jacket water temperature sensor. Failed during CG MIs attendance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2019 Resolved
Circuit directory/tag missing for the engine room heater, relabel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 28 May 2019 Resolved
Forward compartment ladder incorrectly mounted, add/extend ladder rung.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 25 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2019 Resolved
Demonstrate operation of the main engine and steering system.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 28 June 2019
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 August 2005 Resolved
Lifebuoy did not have a buoyant line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 25 October 2005
Resolution: Buoyant line added.
Lifesaving › Lifebuoys › Serviceable
Issued 18 August 2005 Resolved
Lifebuoy had cuts and cracks. Repair or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 25 October 2005
Resolution: new lifebuoy on board.

Casualty record · 1

15 April 2023Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 7674759
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.