MAURY USCG vessel records
← All vessels

CAMERON O

Built
1969
Last inspected
17 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 17 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 15 calendar years (2005–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCW7646
133441
Flag
UNITED STATES
Maury page id
psix-133441

Documentation record

Registered dimensions (L × B × D)47.1 ft × 12.4 ft × 6.3 ft
Registered tonnagegross 24 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPETERSON BUILDERS IN · STURGEON BAY, WI, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTURGEON BAY, WI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 March 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 22

17 July 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8440463
26 June 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8168153
23 July 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7966541
20 May 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7915800
12 April 2024 COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7894382
1 June 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7736100
15 April 2023 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7674759
9 June 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7472654
11 January 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7378868
15 July 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7263820
25 June 2020 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7003095
22 April 2019 Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6719884
12 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6505512
21 May 2015 Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5131002
26 December 2014 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5044411
11 June 2012 Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4341167
28 March 2012 Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4275410
9 January 2012 Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4223162
16 August 2010 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3828168
26 February 2010 DAPI Audit
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3686456
11 December 2008 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3378472
15 June 2005 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2391827

Deficiency record · 27

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 26 June 2025 Resolved
Each towing vessel operating north of lat. 32° N. or south of lat. 32° S. must carry the number of immersion suits as prescribed in this paragraph. Each towing vessel operating in those regions must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person onboard. 01 immersion suit on board was out of service. Replace immersion suit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2025
Resolution: Verified new immersion suit was onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 June 2025 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. Vessel's company is alternating vessel platforms each month for the required monthly drills, instead of conducting one for each vessel. Complete fire drill prior to towing operations for this vessel and continue doing so monthly.
Action required: 705 - Other - as specified
Resolved 11 August 2025
Resolution: Verified shipboard drills were conducted and logged.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 26 June 2025 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel electronic charts out of date. Update electronic charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2025
Resolution: Charts have been updated.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 July 2024 Resolved
Liferaft was off for servicing and no replacement provided.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2024
Resolved 26 July 2024
Resolution: Verified liferaft servicing and proper installation of life raft and hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 May 2024 Resolved
Liferaft on board was overdue for annual servicing.
Action required: 10 - Deficiency Rectified
Due 9 July 2024
Resolved 9 July 2024
Resolution: Vessel swapped liferaft with one from the JIMMY L that had recently been serviced. The JIMMY L is currently out of service due to engineering casualty.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 June 2023 Resolved
Noted vessels name and hailing port not marked on vessels stern. Mark vessels name and hailing port on the stern, with minimum of 4 inch letters as required by 46 CFR 67.123. To be resolved on or before June 15, 2023.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 13 June 2023
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 9 June 2022 Resolved
Company required to provide evidence that vessels annual CG inspection users fee were paid. IAW 46 CFR 2.10-101
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 23 June 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 June 2022 Resolved
Records unavailable CG MI attendance. Company required logbooks and other missing logs or documentation reflecting crew training and inspections conducted iaw 46 CFR 140.905 and 140.405
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 23 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2021 Resolved
Observed previously installed ship service generator removed. Vessel reps stated generator removed, was worn out and was being replaced. O/O to provide spec's of old and new generator being installed. Spec's to be submitted as required by 46CFR 137.200(c).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2021
Resolved 23 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 July 2021 Resolved
O/O to submit drawings and equipment specifications for the ship service generators renewed electrical, fuel oil, cooling water, and exhaust piping. Drawings to be reviewed for compliance to subchapter M, in accordance with 46 CFR 143.250
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2021
Resolved 23 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 July 2021 Resolved
Upon completing installation, in the presence of a CG MI demonstrate operation of the newly replaced and installed ship service generator as required by 46 CFR 143.400
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 6 October 2021
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 July 2020 Resolved
While testing one of the engine room fire detectors, crewmember inadvertently damaged one of the two sensors. O/O to repair, and re-demonstrate detector operating properly.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 28 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 July 2020 Resolved
Observed an open 1 ¼ inch plug in vessels exterior hull plating; port side, outboard of the sink located in the #2 compartment. Install a pipe plug and or properly seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 13 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
Light switch box cover loose in steering compartment, retighten.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 20 June 2019 Resolved
Portable fire/dewatering pump missing portable gas can, obtain & install.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2019 Resolved
Operating station missing high bilge level indicator light, install.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 June 2019 Resolved
Remove trash in the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
Battery charge above generator loose, secure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2019 Resolved
Both life rings, retroreflective tape worn, renew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 20 June 2019 Resolved
Official Number obscured by generator expansion tank, move expansion tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2019 Resolved
Equipped with four Type III PFD's. Missing, outfit vessel with four (04) Type I USCG approved life jackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 June 2019 Resolved
Renew worn forward/bow compartment hatch cover gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 June 2019 Resolved
Dewater forward/bow compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 20 June 2019 Resolved
Expired, and fit vessel with two (02) additional hand held flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2019 Resolved
One B-I portable fire extinguisher in engine room. Install two (02) B-I or one (01) B-II portable fire extinguishers in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 June 2019 Resolved
Installed fixed fire pump missing electric motor and piping. Remove pump, cap off at hull through hull or install electrical motor, missing piping and demonstrate operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 June 2019 Resolved
Missing towing line records, obtain and maintain Section S-10 of the compliance management TVR book.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019

Ownership record