Inspection history · 22
17 July 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8440463
26 June 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8168153
23 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7966541
20 May 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7915800
12 April 2024
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7894382
1 June 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7736100
15 April 2023
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7674759
9 June 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7472654
11 January 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7378868
15 July 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7263820
25 June 2020
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7003095
22 April 2019
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6719884
12 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6505512
21 May 2015
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5131002
26 December 2014
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5044411
11 June 2012
Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4341167
28 March 2012
Administration
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4275410
9 January 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4223162
16 August 2010
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3828168
26 February 2010
DAPI Audit
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3686456
11 December 2008
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3378472
15 June 2005
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2391827
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 26 June 2025
Resolved
Each towing vessel operating north of lat. 32° N. or south of lat. 32° S. must carry the number of immersion suits as prescribed in this paragraph. Each towing vessel operating in those regions must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person onboard.
01 immersion suit on board was out of service.
Replace immersion suit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2025
Resolution: Verified new immersion suit was onboard.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 June 2025
Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month.
Vessel's company is alternating vessel platforms each month for the required monthly drills, instead of conducting one for each vessel. Complete fire drill prior to towing operations for this vessel and continue doing so monthly.
Action required: 705 - Other - as specified
Resolved 11 August 2025
Resolution: Verified shipboard drills were conducted and logged.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 26 June 2025
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel electronic charts out of date. Update electronic charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2025
Resolution: Charts have been updated.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 July 2024
Resolved
Liferaft was off for servicing and no replacement provided.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2024
Resolved 26 July 2024
Resolution: Verified liferaft servicing and proper installation of life raft and hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 May 2024
Resolved
Liferaft on board was overdue for annual servicing.
Action required: 10 - Deficiency Rectified
Due 9 July 2024
Resolved 9 July 2024
Resolution: Vessel swapped liferaft with one from the JIMMY L that had recently been serviced. The JIMMY L is currently out of service due to engineering casualty.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 June 2023
Resolved
Noted vessels name and hailing port not marked on vessels stern. Mark vessels name and hailing port on the stern, with minimum of 4 inch letters as required by 46 CFR 67.123. To be resolved on or before June 15, 2023.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 13 June 2023
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 9 June 2022
Resolved
Company required to provide evidence that vessels annual CG inspection users fee were paid. IAW 46 CFR 2.10-101
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 23 June 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 June 2022
Resolved
Records unavailable CG MI attendance. Company required logbooks and other missing logs or documentation reflecting crew training and inspections conducted iaw 46 CFR 140.905 and 140.405
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 23 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2021
Resolved
Observed previously installed ship service generator removed. Vessel reps stated generator removed, was worn out and was being replaced. O/O to provide spec's of old and new generator being installed. Spec's to be submitted as required by 46CFR 137.200(c).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2021
Resolved 23 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 July 2021
Resolved
O/O to submit drawings and equipment specifications for the ship service generators renewed electrical, fuel oil, cooling water, and exhaust piping. Drawings to be reviewed for compliance to subchapter M, in accordance with 46 CFR 143.250
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2021
Resolved 23 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 July 2021
Resolved
Upon completing installation, in the presence of a CG MI demonstrate operation of the newly replaced and installed ship service generator as required by 46 CFR 143.400
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 6 October 2021
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 July 2020
Resolved
While testing one of the engine room fire detectors, crewmember inadvertently damaged one of the two sensors. O/O to repair, and re-demonstrate detector operating properly.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 28 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 July 2020
Resolved
Observed an open 1 ¼ inch plug in vessels exterior hull plating; port side, outboard of the sink located in the #2 compartment. Install a pipe plug and or properly seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 13 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019
Resolved
Light switch box cover loose in steering compartment, retighten.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 20 June 2019
Resolved
Portable fire/dewatering pump missing portable gas can, obtain & install.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 June 2019
Resolved
Operating station missing high bilge level indicator light, install.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 June 2019
Resolved
Remove trash in the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019
Resolved
Battery charge above generator loose, secure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2019
Resolved
Both life rings, retroreflective tape worn, renew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 20 June 2019
Resolved
Official Number obscured by generator expansion tank, move expansion tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2019
Resolved
Equipped with four Type III PFD's. Missing, outfit vessel with four (04) Type I USCG approved life jackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 June 2019
Resolved
Renew worn forward/bow compartment hatch cover gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 June 2019
Resolved
Dewater forward/bow compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 20 June 2019
Resolved
Expired, and fit vessel with two (02) additional hand held flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2019
Resolved
One B-I portable fire extinguisher in engine room. Install two (02) B-I or one (01) B-II portable fire extinguishers in the engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 June 2019
Resolved
Installed fixed fire pump missing electric motor and piping. Remove pump, cap off at hull through hull or install electrical motor, missing piping and demonstrate operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 20 June 2019
Resolved
Missing towing line records, obtain and maintain Section S-10 of the compliance management TVR book.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 15 July 2019