Inspection history · 53
2 July 2026
Damage Survey · Administrative Inspection · Permit to Proceed
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8425948
21 November 2025
Examination of Repairs · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8270639
5 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7995281
4 October 2023
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7801685
8 August 2023
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7759929
17 July 2023
Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7746760
19 September 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7558214
7 October 2021
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7327710
23 November 2020
Hull Examination · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7092843
19 March 2020
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6928960
1 April 2019
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6649823
31 January 2018
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6347154
15 December 2017
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6325933
13 January 2017
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6070618
9 February 2016
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5808351
19 March 2015
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5085616
10 January 2014
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4781028
23 September 2013
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4721523
28 March 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4272890
13 January 2010
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3662257
23 February 2009
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3422581
1 April 2008
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3175425
29 January 2008
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3138117
13 March 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2886849
2 March 2007
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2882073
10 April 2006
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2616190
20 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2363179
22 April 2005
Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2344280
15 April 2004
Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2043849
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1981826
11 February 2003
Examination of Repairs · Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1740396
26 January 2003
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1735523
26 January 2003
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1736348
27 February 2002
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1489639
22 March 2001
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1415552
1 June 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 819238
21 July 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1416934
6 July 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 155775
4 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 103130
15 July 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129763
2 April 1998
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392918
20 March 1998
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 89419
31 July 1997
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1364385
15 January 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 45212
9 January 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 786216
31 July 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414674
4 October 1995
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398334
8 September 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1371159
6 September 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1171357
29 July 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1161551
23 October 1992
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450735
12 October 1992
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 142009
3 September 1992
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 955554
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 July 2026
No resolution recorded
The OCMI will ensure that every tank vessel is of a structure suitable for the carriage of flammable and/or combustible liquids in bulk and for the proper grade or grades of cargo the vessel carries while in service. The vessel received a puncture to the starboard bow as a result of operations.
46 CFR 31.10-15(a)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019
Resolved
Each cable entrance into explosion proof or flame proof equipment must be made with approved seal fittings, termination fittings, or glands. The port #3 high level alarm electrical seal fitting is worn away exposing wiring. CG Marine Inspector witnessed temporary repair with electrical sealant. 46 CFR 111.105-17(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 1 April 2019
Resolution: Installed new conduit.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 29 January 2008
Resolved
Blanked gauge pipe for #2 port cargo tank was found to have a small hole at the base of the pipe where it meets the deck. Barge rep placed apoxy patch to seal hole. Barge issued 835 to offload cargo and make permanent repairs prior to loading next cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2008
Resolution: Permanent repairs performed at Texas Barge & Boat, Freeport, TX. All to satisfaction
Construction/Loadline › Hull › Sheerstrake
Issued 22 April 2005
Resolved
Insets P & S side, FWD sheerstrakes. Bent upper horizontal brackets in all wing voids. Crop and renew noted areas. See attached repair callouts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2005
Resolved 25 April 2005
Resolution: Damaged areas repaired
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 22 April 2005
Resolved
Correct deficiencies noted during CG inspection
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2005
Resolved 24 April 2005
Resolution: See attached affidavit of repairs
Construction/Loadline › Structures
Issued 26 January 2003
Resolved
Make proper repairs (Suffered during allision at Port Allen, LA) to stern box. Repairs to be completed to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2003
Resolution: Witnesed air test of a 21''x84"x1/2" transom gunnel, 8''x20''x1/2" transom knuckle, 10''x18''x3/8" deck plate, and 8''x21''x1/2" bottom plate inserts.
Construction/Loadline
Issued 1 June 2000
Resolved
Replace wasted gasket on No. 6 port void hatch cover.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Navigation
Issued 15 July 1998
Resolved
Visibility sector screen to port running light required realignment
Condition: Unknown
Due 15 July 1998
Resolved 25 July 1998
Engineering
Issued 15 July 1998
Resolved
Flame screen to fuel tank clogged, requiring servicing/replacement
Condition: Unknown
Due 15 July 1998
Resolved 25 July 1998
Construction/Loadline
Issued 31 July 1997
Resolved
Crop and renew 8 overhead brackets_x001C_ Gouge and reweld 27 longitudinal frame butt weld
Condition: Unknown
Due 26 December 1997
Resolved 26 December 1997
Deck/Cargo
Issued 8 September 1995
Resolved
SERVICE AND CONDUCT OPERATION TEST OF LIQUID OVER-FILL PROTECTION ALARM ON # ONE STARBOARD CARGO TANK. CORRECTED PRIOR TO DEPARTING SHIPYARD.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995