Records from 2001 to 2022. Most recent: inspection, 30 June 2022.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEST GULF MARINE · GALVESTION, TX, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 40
30 June 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7489978
6 June 2022
Deficiency Check · Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7469711
12 September 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6813789
28 February 2019
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6920370
21 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6472845
20 March 2018
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6393208
22 February 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6364237
22 February 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6393154
9 May 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6141928
1 May 2017
Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6136116
9 June 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5960603
20 July 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5191131
20 July 2015
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5191359
16 April 2015
Periodic Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5108769
2 April 2015
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5095518
2 April 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5097480
25 February 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4842953
22 July 2013
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4718770
17 May 2012
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4314186
16 March 2012
Cargo Tank Internal · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4264182
16 December 2010
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4625366
7 May 2010
Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3733103
10 March 2009
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3563130
28 February 2008
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3253398
27 September 2007
Examination of Repairs
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 3067572
26 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3066526
20 April 2007
Deficiency Check · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2911886
22 February 2007
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875613
16 February 2007
COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2872765
17 January 2007
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2857198
10 June 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2706572
25 May 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2564484
20 May 2005
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2363669
13 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2006084
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966893
21 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1747767
19 September 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1677725
15 September 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1676883
26 February 2002
Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1489329
30 October 2001
Construction Oversight
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1480321
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2018
Resolved
12' x 3' x 4" inset located on stbd side aprox. 35' forward fm stbd stern corner. No fractures or cracks associated with inset. Void is free of water and being monitored by crew
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2018
Resolved 20 March 2018
Resolution: 15'x 6' x 3/8" insert. Air tested sat.
Construction/Loadline › Hull › Hull Plating
Issued 20 July 2015
Resolved
Vsl involved in collision and sustained damage IWO #6 & #7 P wing voids, #3 P cargo tank, & P slop tank. Vsl directed to discharge cargo IAW discharge plan approved by IC. After discharge, provide marine chemist cert for follow-on damage survey by attending MI. No further cargo ops permitted until permanent repairs completed to satisfaction of attending MI. (46 CFR 32.60-1) (Prior to operations)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2015
Resolution: Repairs made to the satisfaction of attending Marine Inspector.
Construction/Loadline › Hull › Side Shell
Issued 2 April 2015
Resolved
After discharging LCO, crop and renew through hole and fracture to area 9ft astern and 1 ft below deck near bow on port side (below chock) in accordance with NVIC 7-68 prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2015
Resolved 23 April 2015
Construction/Loadline › Hull › Hull Plating
Issued 16 March 2012
Resolved
Called out approx 3' x 3' insert on strbd bow knuckle. Called out approx 5' x 4' insert on bow rake at waterline port side. Called out approx 4' x 3' insert on port side stern box.
Action required: 705 - Other - as specified
Resolved 17 April 2012
Resolution: Visually inspected inserts, sat. Witnessed air test conducted at 2 p.s.i. using soapy water, sat.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 28 February 2008
Resolved
Port #1 High level/Overfill Alarm not working properly.
Due 12 April 2008
Resolved 28 February 2008
Resolution: Electrically repaired alarm.
Deck/Cargo › Towing › Chocks
Issued 16 February 2007
Resolved
Properly weld repair the #2 port kevil which has been pulled off of the deck on the forward end.
Due 16 March 2007
Resolved 24 April 2007
Resolution: Repaired to the satisfaction of the attending Coast Guard Marine Inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 16 February 2007
Resolved
Prove proper operation of the cargo pump engine and remote shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2007
Resolved 16 February 2007
Resolution: Found cargo pump engine leaking coolant and requiring maintainence. Leaking hose was corrected same day.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 16 February 2007
Resolved
Prove proper operation of the port #2 cargo tank high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2007
Resolved 16 February 2007
Resolution: Alarm sensor was found to be frozen due to moisture and artic temps. Sensor was loosened up and operated as designed.
Construction/Loadline › Structures › Manhole
Issued 16 February 2007
Resolved
Open all void hatches for inspection.
Due 26 February 2007
Resolved 16 February 2007
Resolution: All void hatches were frozen in place due to icing conditions. All were loosened and opened for inspection.