Records from 1992 to 2010. Most recent: inspection, 8 February 2010.
Inspection history · 59
8 February 2010
COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3675667
26 April 2009
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3461225
26 April 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3461247
13 April 2009
Administrative Inspection · COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3448828
2 March 2009
COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3426500
7 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3413717
26 November 2008
NPV Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3366075
16 November 2008
COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3366265
25 March 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3172463
28 November 2007
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3106245
21 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2892333
2 March 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2882995
28 June 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2694383
28 June 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2694749
26 May 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2659596
27 November 2005
Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2541336
3 November 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2527915
19 October 2005
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2521230
14 October 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2514368
24 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2268485
16 December 2004
Ballast Water Examination · COC-TVE Annual · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2257707
2 June 2004
Ballast Water Examination · MTSA/ISPS Verification · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2086806
20 February 2004
Damage Survey · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2010240
19 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2014548
25 November 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1954233
24 November 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1955577
19 November 2003
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1951321
26 June 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1827773
3 March 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1751877
6 December 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1715603
9 April 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1634128
3 January 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1475321
15 November 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 295581
15 November 2001
Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1076830
14 June 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 291062
27 July 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 431419
12 August 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 419224
30 July 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 418690
30 July 1998
Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1130078
1 April 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 83148
27 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 538619
30 July 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 406280
20 February 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 502743
30 December 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 398896
22 November 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 161652
7 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 394095
29 April 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 390640
28 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 438947
24 October 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 384403
9 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382271
9 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1181532
20 March 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 481318
18 August 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1459117
15 April 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 365993
2 September 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1147103
25 July 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 437617
24 March 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 357059
4 December 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354878
6 September 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 951821
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 27 November 2005
Resolved
Overfill alarms inoperative and/or damaged on tanks 5,3,1. Repair alarms and test to the satisfaction of the vessel class society prior to next U.S. Port.
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 15 December 2005
Resolution: Recived Fax from Class attesting to the satisfactory repain of tank overflow alarms.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 16 December 2004
Resolved
Cargo tank 5 and 6 high level alarms are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2004
Resolved 24 December 2004
Resolution: Rcvd class report from DNV stating outstanding deficiency has been rectified .
Construction/Loadline › Hull
Issued 20 February 2004
Resolved
Provide written repair proposal to COTP New Orleans on the repairs to damaged area of the ship. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 20 February 2004
Resolution: Received satisfactory report from DNV.
Construction/Loadline › Hull
Issued 20 February 2004
Resolved
Permanently repair damage area of the ship to satisfaction of classification society. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 12 March 2004
Resolution: Received satisfactory report from DNV stating that permanent repairs were carried out.
Deck/Cargo › Ballast
Issued 20 February 2004
Resolved
Remove oil from the No. 7 water ballast tank. Provide written transfer procedure to the COTP New Orleans. LEGACY COMPONENT DESC: Segregated Ballast Tank
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 12 March 2004
Resolution: Recieved acceptable transfer procedures and verification that oil was removed from DNV.
Deck/Cargo › Inert Gas System
Issued 19 November 2003
Resolved
PORTABLE EXPLOSIVE GAS METERS INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 25 November 2003
Resolution: Combustible gas indicators renewed.
Engineering
Issued 15 November 2001
Resolved
Repair permanently to the satisfaction of class the leaking temporary patchon the #1 generator cooling water inlet pipe to the L/O cooler.
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
Engineering
Issued 15 November 2001
Resolved
Repair permanently to the satisfaction of class the leaking temporary patchon the #2 generator cooling water pipe in the front of the engine.
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
Engineering
Issued 15 November 2001
Resolved
Repair permanently to the satisfaction of class the leaking temporary patchon the inport cooling water pump discharge line located on the starboard lower level of the engineroom.
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
Fire Fighting
Issued 15 November 2001
Resolved
Repair permanently to the satisfaction of class the leaking temporary patchon the main fire line on port side lower level E/R.
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
Construction/Loadline
Issued 15 November 2001
Resolved
Repair permanently to the satisfaction of class the leaking temporary patchon the main ballast line in cargo pump room.
Condition: Unknown
Due 1 December 2001
Resolved 1 December 2001
Engineering
Issued 30 July 1998
Resolved
LEAKING FUEL PIPING ON TOP SIDE OF BOILER_x001C_ SOLAS 74 (amended) REG II-2/15.2
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Engineering
Issued 30 July 1998
Resolved
2-1/2inch PIPE FLANGE LOCATED ON L/O-F/W COOLER MANIFOLD, STBD SIDE-FWD BLKHEAD-LOWER LEVEL ENGINE ROOM. SOLAS 74(amended)REG II-1/26.1
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Deck/Cargo
Issued 18 August 1994
Resolved
PROVIDE A MARINE CHEMIST AND MAKE THE CARGO PUMPROOM AVAILABLE FOR INSPECTION PRIOR TO CARGO OPERATIONS NEXT U.S. PORT.
Condition: Unknown
Due 25 August 1994
Resolved 26 August 1994
Deck/Cargo
Issued 18 August 1994
Resolved
PROVE OPERATION OF THE CARGO PUMP EMERGENCY SHUTDOWN SYSTEM PRIOR TO CARGO OPERATIONS NEXT U.S. PORT.
Condition: Unknown
Due 25 August 1994
Resolved 26 August 1994