This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1632 - Simplified, Gross Ton
1306 - Simplified, Net Ton
Maury page id
psix-33259
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
TBSIP report of wastage of #1 port cargo tank top.
Condition: Damaged By Earlier Event
Due 30 October 2015
Resolved 29 October 2015
Resolution: Cropped and renewed 3/8"x6'-0"x6'-0" insert in way of #1 port tank top. Witnessed 1 psi air test of repairs, test sat.Permanent repairs made to the satisfaction of attending CG Marine Inspector.
Construction/Loadline › Structures › End Bulkhead
Issued 24 March 2014Resolved
Vessel has a 6 foot long and 12 inch deep inset on its stern box. Ordered to make repairs prior to cargo.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2014
Resolved 14 May 2014
Resolution: Cropped and renewed eight 8''X5"x3" external vertical stiffeners on the #3 Cargo tank in the stern box. Conducted a visual exam of all repairs and witnessed air test. Test satisfactory.
Construction/Loadline › Penetrations › Weld
Issued 15 June 2013Resolved
Make permanent repairs to 6" spigot patch located on #3 stbd tank top underneath the loading header drip tray. Weld seam found to be cracked through, allowing oil to seap up and out onto cargo tank deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2013
Resolved 2 July 2013
Resolution: Repairs made to the satisfaction of attending Marine Inspector in SWSY Channelview, Houston TX.
Construction/Loadline › Structures › Deck Plating
Issued 19 July 2007Resolved
1/8" hole in 1 starboard cargo tank. Temp patch was insert and vessel received PTP until permanent repairs are completed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 2 August 2007
Resolution: Conducted repair check. Examined welds and witnessed satisfactory air test of 1200 sq. ft. of 5/16" tank top plate fitted to the #1 port and stbd cargo tanks.