Records from 1996 to 2018. Most recent: inspection, 9 July 2018.
Inspection history · 34
9 July 2018
COE-Dockside
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6464086
7 March 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6367422
6 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6140132
28 April 2017
Ballast Water Examination · PII Safety Exam · COE-Dockside · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6130170
22 April 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6130191
17 August 2016
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5975282
30 May 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5891885
20 May 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5883311
16 May 2016
ISPS II Exam · Administrative Inspection · PII Safety Exam · COE-Dockside · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5878333
22 March 2014
Deficiency Check · Ballast Water Examination · Damage Survey · PI Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4821052
22 March 2014
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4821272
13 March 2014
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4815779
22 February 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4242116
27 June 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3248235
10 February 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3144972
9 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3144565
9 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146151
14 January 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130112
8 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3126836
11 December 2007
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3112552
6 October 2006
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2794433
26 October 2005
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2522451
9 June 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2093836
2 June 2004
Re-Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2085910
2 June 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2086110
30 July 2003
MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1850885
21 July 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1876088
24 September 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 293814
18 November 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 434937
17 June 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 429867
15 November 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422665
7 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 147064
29 September 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 408311
25 October 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396729
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 28 April 2017
Resolved
EACH CARGO HOLD SHALL BE PROVIDED WITH AT LEAST 02 MEANS OF ACCESS AS FAR APART AS PRACTICABLE. PSCE NOTED #2 CARGO HOLD AFT VERTICAL LADDER HAD CARGO LOADED ON TOP OF IT AND DAMAGE TO THE PLATFORM. #3 CARGO HOLD AFT VERTICAL LADDER HAD CARGO LOATED ON TOP WITH MAJOR DAMAGE TO THE LADDERS AND PLATFORM. DAMAGE RENDERS LADDERS UNSERCIVABLE. 74SOLAS(04)II-I/3-6.3.3.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2017
Resolved 6 May 2017
Resolution: Repaired or replaced ladders. Cleared Form B.
Construction/Loadline › Hull › Hull Plating
Issued 22 March 2014
Resolved
Admin shall satisfy itself that the general structural strength of the ship is adequate for the draught corresponding to the freeboard assigned. Vessel was involved in a collision which caused hull ruptures on the bulbous bow. (ICLL amend 88, I/1) (17ac)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2014
Resolution: Repairs completed to bulbous bow; reviewed class report of extensive repairs to damaged area. Vessel released from COTP order hold.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 22 March 2014
Resolved
EPIRB shall be capable of floating free if the ship sinks. EPIRB is currently stowed underneath a horizontal steel member or ledge which could trap the EPIRB and prevent it from floating free. (74 SOLAS 09 con. IV/7.1.6.4) (17ac)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2014
Resolution: EPIRB mounted in new location that will allow it to float free to the satisfaction of the Coast Guard and classification society.
Navigation › Piloting/Steering › Gyro Compass
Issued 13 March 2014
Resolved
Vessel's gyrocompass inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: SEC HOU/GAL PSC Branch received a technician report from Sperry Marine.The report stated: gyrocompass operating normally. After reviewing the technician report, PSC Branch approved the release from restriction and cleared the defici
Engineering › Compressed Air System (control) › Valve
Issued 10 February 2008
Resolved
Pilot reported to USCG for a loss of control air on the Main Engine while maneuvering upriver to the anchorage.
Action required: 705 - Other - as specified
Due 10 February 2008
Resolved 10 February 2008
Resolution: Received report from [name withheld] attesting to satisfactory repairs.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 14 January 2008
Resolved
On 25 Dec 2007 in Buenanventra, Columbia during port manuvering operations, the Portside Anchor with 3 lengths were lost due to the chain parting.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 January 2008
Resolution: GL surveyor observed the port side anchor and chain. Surveyor performed function test, all repairs inspected tested and satisfactory. Received class survey report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 December 2007
Resolved
.Vessel has an inoperable oily water separator due to a crack in the sensing module. Damage was found by Chief Engineer on 01DEC2007 and reported by vessel on an incident report per ship Safety Management System. Parts are removed, ordered and they are waiting replacement parts. Make permanent repairs to satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 January 2008
Resolution: Received class report from GL survey attesting to the install of new 15 ppm alarm. Was tested by GL surveyor and found to be working properly.
Lifesaving
Issued 18 November 1999
Resolved
DEMONSTRATE A PROPER LIFEBOAT DRILL TO THE SATISFACTION OF MSO TAMPA_x001C_ BOARDING OFFICERS.
Condition: Unknown
Due 18 November 1999
Resolved 19 November 1999