Records from 2016 to 2026. Most recent: inspection, 21 April 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT FLORIDA TRADING LLC · TAVARES, FL, UNITED STATES · built 2007
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeShip
Hull configurationTwin Hull
Hailing portBLUE SPRING, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
21 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8353329
17 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8094877
1 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7888194
3 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7757839
6 July 2022
COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7499029
22 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7233141
28 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6804846
14 August 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6783966
15 August 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6513796
12 July 2017
COI Inspection · DAPI Audit · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6207883
21 September 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6006157
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of Navigation Rules. Vessels' port and stbd running lights are not working. Vessel is restricted to day light operations until corrected.
46 CFR 183.420
Code 705 c
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 24 April 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 August 2023
Resolved
Each lighting fixture must comply with 46 CFR 183.200. Minimize accidental personnel contact with energized parts. The vessel has lighting fixtures that need to be replaced, repaired or removed. Forward STBD, midship port side and three running the center line of the vessel. Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 17 April 2025
Resolution: Removed old light fixtures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2021
Resolved
All accessories installed in the fuel line must be independently supported. Fuel filters installed without securing nuts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 2 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2021
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Floating waterlight inoperable.
Action required: 705 - Other - as specified
Resolved 19 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2019
Resolved
Provide one 2.5 gallon fire bucket with lanyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2019
Resolved
Provide 5 type I PFD's. Vessel passenger count restricted to 57 until provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2019
Resolved
Renew fuel lines with USCG A or B hose and double clamp.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019
Resolved
Renew or replace broken deck lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 14 August 2019
Resolved
Removed exposed metal or provide suitable protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2017
Resolved
renew ring bouy.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 12 July 2017