Records from 1993 to 2026. Most recent: inspection, 21 April 2026.
Inspection history · 42
21 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8353329
17 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8094877
1 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7888194
3 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7757839
6 July 2022
COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7499029
22 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7233141
28 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6804846
14 August 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6783966
15 August 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6513796
12 July 2017
COI Inspection · DAPI Audit · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6207883
21 September 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6006157
26 July 2012
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4392234
3 November 2010
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3809440
30 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3335654
17 September 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3326888
20 September 2007
Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3062200
25 May 2007
Plan Review "T" Boat · Deficiency Check · Simplified Stability Test · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2940146
21 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2936217
20 April 2007
Simplified Stability Test · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2911823
3 May 2006
Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2637736
19 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2572486
19 January 2006
Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2575882
17 May 2005
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2361062
5 May 2005
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2349364
4 May 2004
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2058249
1 March 2004
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2033301
13 January 2004
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1983471
24 June 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1824631
15 January 2003
Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1731262
10 June 2002
COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1629853
3 July 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1468226
11 August 2000
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 821907
31 January 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 815192
25 January 2000
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 814541
1 June 1999
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1369211
23 March 1998
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1418313
26 February 1997
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1468406
27 February 1996
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 884446
23 February 1996
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1081337
6 March 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 860625
23 February 1994
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1165007
24 February 1993
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1150024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of Navigation Rules. Vessels' port and stbd running lights are not working. Vessel is restricted to day light operations until corrected.
46 CFR 183.420
Code 705 c
Action required: 705 - Other - as specified
Due 1 May 2025
Resolved 24 April 2025
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 August 2023
Resolved
Each lighting fixture must comply with 46 CFR 183.200. Minimize accidental personnel contact with energized parts. The vessel has lighting fixtures that need to be replaced, repaired or removed. Forward STBD, midship port side and three running the center line of the vessel. Correct to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2023
Resolved 17 April 2025
Resolution: Removed old light fixtures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2021
Resolved
All accessories installed in the fuel line must be independently supported. Fuel filters installed without securing nuts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 2 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2021
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Floating waterlight inoperable.
Action required: 705 - Other - as specified
Resolved 19 July 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 August 2019
Resolved
Provide one 2.5 gallon fire bucket with lanyard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2019
Resolved
Provide 5 type I PFD's. Vessel passenger count restricted to 57 until provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2019
Resolved
Renew fuel lines with USCG A or B hose and double clamp.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019
Resolved
Renew or replace broken deck lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 14 August 2019
Resolved
Removed exposed metal or provide suitable protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2019
Resolved 28 August 2019
Lifesaving › Lifebuoys › Serviceable
Issued 12 July 2017
Resolved
renew ring bouy.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 12 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2012
Resolved
Replace expired items in First aid kit.
Due 27 July 2012
Resolved 26 July 2012
Engineering › Fuel Oil Service System › Hose
Issued 24 July 2012
Resolved
Add clamp to fuel hose.
Due 27 July 2012
Resolved 26 July 2012
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 17 September 2008
Resolved
Update electrical plan to include VHF-FM radio for approval not later than 19 Oct 08.
Action required: 705 - Other - as specified
Due 19 October 2008
Resolved 30 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 August 2007
Resolved
Revised electrical drawings reflecting actual onboard installations shall be submitted for review and approval.
Action required: 705 - Other - as specified
Due 29 September 2007
Resolved 20 September 2007
Resolution: Received revised electrical drawings and approved.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 April 2007
Resolved
Non water tight wiring terminals used to repair a 12 volt power wire that had corroded and is no longer serviceable. Issued a CG 835 to properly repair wiring.
Condition: Improper Installation
Due 25 May 2007
Resolved 21 May 2007
Resolution: Corrected
Fire Fighting › Fire Bucket › Availability
Issued 20 April 2007
Resolved
Issued a CG 835 to place 3 ea 2.5 Gal fire buckets (W/lanyards and "FIRE BUCKET" stenciled on buckets) onboard when vessel is in service.
Condition: Unknown
Due 30 April 2007
Resolved 27 April 2007
Resolution: Fire buckets have been place onboard.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 20 April 2007
Resolved
Vessel required to provide fixed seating in accordance with 46 CFR 177.820 prior to placing vessel in service.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 27 April 2007
Resolution: Existing seating has been fastened to the deck of the vessel..
Construction/Loadline › Hull › Side Shell
Issued 20 April 2007
Resolved
Issued a CG 835 to submit a plan to properly repair the damage on the STBD pontoon at compartments 9 & 12 .
Condition: Damaged By Earlier Event
Due 30 September 2007
Resolved 10 August 2007
Resolution: New hulls fabricated and attached to vessel.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 January 2006
Resolved
Complete permanent repairs during next dry dock.
Action required: 705 - Other - as specified
Resolved 11 May 2006
Resolution: Completed. Received fax copy of invoice indicating repairs have been completed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 5 May 2005
Resolved
Replace retroreflective material on ten PFD
Due 12 May 2005
Resolved 18 May 2005
Resolution: retroreflective tape replaced on ten PFD
Accommodation/Occupational Safety
Issued 4 May 2004
Resolved
REPAIR RAILS
Due 11 May 2004
Resolved 7 May 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 24 June 2003
Resolved
REPLACE RETRO REFLECTIVE TAPE ON (2) ADULT LIFEJACKETS
Due 8 July 2003
Resolved 4 July 2003
Construction/Loadline › Penetrations › Weld
Issued 29 January 2003
Resolved
PROVIDE ACCESS TO PONTOON FROM DECK
Due 30 May 2003
Resolved 26 July 2004
Resolution: O/O and MSO JAX agrred to annual hull inspection of pontoons in leiu of installing inspection ports on the vessel. SEE SPECIAL NOTES.
Electrical › Electric Supply System (service)
Issued 15 January 2003
Resolved
INSTALL WATER TIGHT COVERS OVER BATTERY SWITCHS
Due 22 January 2003
Resolved 24 January 2003
Electrical
Issued 15 January 2003
Resolved
INSTALL CHAFING GEAR OVER WIRES STBD SIDE AT COMPARTMENT # 11.
Due 22 January 2003
Resolved 24 January 2003
Engineering › Fuel Oil Service System
Issued 1 June 2002
Resolved
LABLE LOCATION OF EMERGENCY FUEL SHUT OFF VALVES.
Due 24 June 2002
Resolved 11 June 2002
Navigation
Issued 3 July 2001
Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Construction/Loadline
Issued 3 July 2001
Resolved
PROVIDE OPENING ON DECK OF VESSEL FOR BILGE PUMPING IN ALL SPACES.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Lifesaving
Issued 3 July 2001
Resolved
LABLE RING BUOY.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Electrical
Issued 3 July 2001
Resolved
COMPLETE PERMANENT WIRING OF INVERTER.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Construction/Loadline
Issued 3 July 2001
Resolved
PROVIDE HAND BILGE PUMP FOR VESSEL.
Condition: Unknown
Due 9 July 2001
Resolved 10 July 2001
Engineering
Issued 3 July 2001
Resolved
RENEW FUEL LINES WITH USCG APPOVED LINES AND DOUBLED CLAMPED.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Fire Fighting
Issued 3 July 2001
Resolved
PROVIDE AND MOUNT FIRE EXTINGUISHER BRACKET.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Electrical
Issued 3 July 2001
Resolved
INSTALL BATTERIES BOXES AND COVERS.
Condition: Unknown
Due 9 July 2001
Resolved 9 July 2001
Electrical
Issued 11 August 2000
Resolved
COMPLETE PERMANENT INSTALLATION OF INVERTER (MOUNTING AND WIRING)
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Lifesaving
Issued 11 August 2000
Resolved
RENEW RING BUOY
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Engineering
Issued 11 August 2000
Resolved
PROVIDE DOCUMENTATION OR RENEW FUEL LINES WITH USCG APPROVED LINES DOUBLED CLAMPED.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Fire Fighting
Issued 11 August 2000
Resolved
PROVIDE FIRE EXTINGUISHER BRACKET AND LABEL STOWAGE OF EXTINGUISHER LOCATEDIN HEAD.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Documentation
Issued 11 August 2000
Resolved
POST EMERGENCY INSTRUCTIONS.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Navigation
Issued 1 June 1999
Resolved
CORRECT IMPROPERLY DISPLAYED STERN LIGHT ON VESSEL'S CANOPY. STERN LIGHT IS 180 DEGREES OUT OF PROPER POSITION.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Electrical
Issued 1 June 1999
Resolved
PROPERLY TERMINATE ELECTRICAL (12 VOLT) CONNECTION TO MSD.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Lifesaving
Issued 1 June 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 1 June 1999
Resolved
UPDATE COMPANY DRUG TESTING POLICY TO RELFECT SUBMISSION OF REQUIRED MIS FORM (CG-5573) TO COMMANDANT (G-MOA) ANNUALLY. ALSO, PROVIDE PROOF OF SUBMISSION OF SAME FORM FOR 1998.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 1 June 1999
Resolved
PROVIDE EVIDENCE OF CORRECTED STATE OF FLORIDA REGISTRATION REFLECTING VESSEL IS IN COMMERCIAL SERVICE AND CORRECT MODEL YEAR & LENGTH.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Engineering
Issued 1 June 1999
Resolved
REPLACE FUEL LINES (P&S) WITH MARINE GRADE/ABYC APPROVED FUEL LINES. ENSUREEND FITTINGS ARE APPROPRIATE.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Engineering
Issued 1 June 1999
Resolved
PROVIDE MEANS FOR SECURING PORTABLE FUEL TANKS (P&S) TO STERN TO PREVENT LOSS.
Condition: Unknown
Due 1 June 1999
Resolved 1 June 1999
Documentation
Issued 23 March 1998
Resolved
PROVIDE PROOF OF CURRENT STATE REGISTRATION.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Accommodation/Occupational Safety
Issued 23 March 1998
Resolved
PROVIDE MEANS TO LOCK OR SECURE MSD DISCHARGE OPENING.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Electrical
Issued 23 March 1998
Resolved
REROUTE ELECTRICAL WIRES FROM BATTERY POST TO ENSURE NO CHAFFING OF THE ELECTRIC WIRES AND REPLACE THE BATTERY WIRE LEADING TO INVERTER WITH MARINEGRADE WIRE OF APPROPRIATE SIZE.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Navigation
Issued 23 March 1998
Resolved
REPAIR OR REPLACE THE COMBINATION ANCHOR/FORWARD WHITE LIGHT. VSL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL CORRECTED.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998
Resolved
PROVIDE 3-6FT LANYARD WITH MARINE GRADE SNAP HOOK ON RING BUOY WATER LIGHT.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998