Records from 1992 to 2026. Most recent: inspection, 13 January 2026.
Inspection history · 40
13 January 2026
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8295276
25 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8083846
4 August 2024
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8015499
30 January 2024
Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7857709
17 January 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7622245
15 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7431785
19 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7381795
1 March 2021
Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7147858
8 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6408996
20 October 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5749177
15 March 2015
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5086197
17 February 2015
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5086237
19 July 2013
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4658042
17 July 2013
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4656211
2 November 2012
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4477371
2 March 2012
Administration
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4274027
3 March 2010
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3690265
15 March 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2997395
2 November 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2813181
20 January 2006
Annual Inspection · Hawser Check · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2573675
19 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2572486
19 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3050965
2 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2448864
13 December 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2259332
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970592
18 November 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1949858
12 November 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1946230
6 August 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1903369
3 February 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1739219
22 January 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1734063
27 February 2001
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1058729
25 July 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 164245
1 December 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 175901
30 December 1997
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 783592
16 September 1996
MARPOL Annex I Examination · MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1268478
10 September 1996
MARPOL Annex I Examination · MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1265648
10 January 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 89371
10 December 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 8563
10 December 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 99104
26 April 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 86106
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 13 January 2026
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
Glow in the dark tape was worn and in need of replacement.
Action required: 10 - Deficiency Rectified
Resolved 26 February 2026
Resolution: New tape was applied to replace the old, worn tape.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 February 2025
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency
conditions to facilitate egress from each space.
E-light in fwd hold did not illuminate when tested
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 28 February 2025
Resolution: Rcvd email pic from vessel rep of fully functioning e-light in fwd hold.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 25 February 2025
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel.
Air compressors require guards on the inboard side of the rotating pulley system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 14 March 2025
Resolution: Picture provided of a newly constructed and installed expanded metal guard for the pulley system
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Dryer has no bushing or connector for the power cable penetrating the sheet metal backing, causing damage to the cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 28 February 2025
Resolution: Rcvd picture of installed connector for the dryer electrical feed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 January 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High Bilge levels.
A bilge alarm needs to be installed in the forward void.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2024
Resolved 3 March 2024
Resolution: Bilge Alarm installed in the fwd hold, as evidenced by pictures provided by vsl rep.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 January 2022
Resolved
Each towing vessel must be maintained and operated as to minimize fire hazards and to ensure: storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. The valves (bottom location) for sight glasses on F/O tanks #1 & #2 have a small leak. Show proof of repairs to the valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2022
Resolved 24 January 2022
Resolution: #1 and #2 F/O tank sight glasses were repaired and the leak was stopped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 January 2022
Resolved
A towing vessel must carry lifebuoys as follows: lifebuoys must have the following attachments: at least 1 lifebuoy must have a lifeline of dark color if synthetic, or type certified resistant to UV light. Corrected prior to departing vessel.
Action required: 10 - Deficiency Rectified
Resolved 19 January 2022
Resolution: Lifeline was replaced prior to departing vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 January 2022
Resolved
For vessels having a square bow, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow. Vessel did not have the name of the vessel permanently affixed to the bow.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2022
Resolved 24 January 2022
Resolution: Names were permanently placed on the port and starboard bow.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 January 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces & lounges. The galley smoke detector was replaced and tested satisfactorily.
Action required: 10 - Deficiency Rectified
Resolved 19 January 2022
Resolution: A new smoke detector was tested and placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2021
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Prove proper operation of bilge
System using installed piping. 46CFR143.275
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 April 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 March 2021
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly and labeled. Ensure doors are labeled
pass a hose test 2 Port and 1 stb fwd door. 46CFR140.610(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: Doors have passed a hose test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2021
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Quick
release valve is not operating as designed. prove proper
operation. 46CFR143.260(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 2 March 2021
Resolved
The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Certificates and
identification tags are missing for wires. 46CFR140.801(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: Wires certs and ID tags no longer missing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2021
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearing, and electrical equipment and systems must be maintained to ensure proper operation, be suitable for route and service; and have suitable propulsion controls to provide the operating full control at each operating station. Stbd rudder bearing
is leaking sea water. 46CFR143.205(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 April 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 March 2021
Resolved
Each towing vessel must be equpped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. ensure first aid kit complies with the
requirements. 46CFR140.435
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: New First Aid Kit onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2021
Resolved
Refresher training must be repeated annually and may be conducted over time in modules covering specific topics. Refresher training may be less comprehensive, provided that the information presented is sufficient to provide employees with continued understanding or workplace hazards. Ensure refresher training is completed. 46CFR140.515(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 27 April 2021
Resolution: Refresher training has been completed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2021
Resolved
Machinery sytems must be maintained to ensure safe
operation of towing vessel. Find and secure fuel leaks
in engine room piping. 46CFR 143.205
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: Fuel leaks secured
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2021
Resolved
The master of a towing vessel must ensure that drills are conducted and instruction are given to ensure that all crewmembers are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats of life, property, or the environment. Ensure duties and instructions are available for all crew. 46CFR140.420(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 3 March 2021
Resolution: Sation Bill was updated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2021
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
Flammable storage locker on aft deck can not be used. 46CFR142.225(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2021
Resolution: Flammable storage locker on deck is usable
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 2 March 2021
Resolved
Safety orientations and other crew training must be documented in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. The entry must include the date of the safety orientation training, a general description of the training topics, the name and signatures of the individuals providing the orientation and training and the names of the individuals receiving the safety orientation or training. Ensure all crew is conducting safety orientation as required. 46CFR140.410(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2021
Resolution: Safety orientation is now being completed and required when a year passes after crew last worked on the specific vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 2 March 2021
Resolved
No person may operate any vessel equpped with installed toilet facilities unless it is equipped with: an operable Type II or III device that has a label on it under 159.16 or that is certified under 159.12 or 159.12a or an operable Type I device that has a label on it under 159.16 or that is certified under 159.12 if the vessel is 65 feet or less in length. Hole present on MSD lid. Replace to ensure integrity of the sanitation device. 33CFR159.7(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 27 April 2021
Resolution: MSD lid was replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2021
Resolved
The hose must be lined commercial fire hose 50 feet in length at least 1.5 inches in diameter and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern.
Replaced broken nozzle and tested to 50 psi per regulation. 46CFR142.325(d)
Action required: 10 - Deficiency Rectified
Resolved 2 March 2021
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2021
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems must be maintained to ensure proper operation.
Cotter pin replaced in reduction gear control. 46CFR143.205(c)
Action required: 10 - Deficiency Rectified
Resolved 2 March 2021
Resolution: Corrected on the spot.