Records from 1998 to 2026. Most recent: inspection, 12 January 2026.
Inspection history · 61
12 January 2026
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8294855
12 August 2025
Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8208261
19 December 2024
Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8049401
2 October 2023
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7802201
13 March 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7650202
16 February 2023
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7637559
12 October 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7575595
29 September 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7322337
21 September 2020
Internal Structural Exam · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7054130
12 December 2019
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6855698
21 March 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6646866
27 December 2018
Periodic Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6603165
22 March 2018
Cargo Tank Internal · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6375791
10 February 2018
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6355188
27 September 2017
Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6280043
5 May 2017
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6141911
7 February 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6083801
1 February 2017
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6081195
9 September 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5996569
11 May 2016
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5874616
28 September 2015
COI Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5730199
31 October 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5015470
20 March 2014
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4823267
6 December 2013
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4764807
5 November 2013
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4733056
12 September 2013
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4713409
12 December 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4499623
31 October 2011
Annual Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4372864
13 December 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4000219
29 September 2010
MTSA Verification · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3858598
7 May 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3469768
13 November 2008
Internal Structural Exam · Hull Examination · Annual Inspection · Cargo Tank Internal
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3361515
24 September 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3331605
22 April 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3189714
19 February 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3152983
27 December 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3118072
24 October 2006
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2821142
20 October 2006
MTSA Verification · Internal Structural Exam · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2802428
19 January 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2572486
26 September 2005
COI Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2501706
21 September 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2498158
2 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2448915
10 June 2005
MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2389468
10 December 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2256120
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1991476
4 November 2003
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1941146
18 February 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1747729
24 January 2003
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1734982
23 January 2003
Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1734277
22 January 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1734063
22 November 2002
Periodic Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1713868
4 June 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1627918
26 November 2001
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 772333
31 October 2001
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1426683
15 October 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 524982
22 June 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 516027
4 October 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1468599
24 April 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 140144
15 October 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1381700
27 April 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 155798
9 October 1998
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1402701
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 December 2024
Resolved
Table 1 to § 34.50-10(a) indicates the minimum required number and type for each space listed. Extinguishers with larger numerical ratings or multiple letter designations may be used if the extinguishers meet the requirements of the table (required 2 40-B). Vessel had 2 10-B extinguishers.
Action required: 66 - Prior to drilling or production operations
Resolved 20 December 2024
Resolution: Installed proper portable FE IAW COI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 March 2023
Resolved
EACH TANK VESSEL MUT UNDERGO DRY-DOCK & INTERNAL STRUCTURAL EXAMINATIONS AS PER 46 CFR 31.10-21
Action required: 703 - Prior to bunkering operations
Resolved 8 January 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 December 2018
Resolved
Each pressure gauge must be calibrated annually. The cargo pump discharge pressure gauge was last calibrated on 01/05/2017.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2019
Resolved 9 January 2019
Resolution: Vessel rep submitted photos of gauge calibrated on 07JAN18.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 December 2018
Resolved
The paint on the navigation light screens is wearing off. Repaint the screens a matt black.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 January 2019
Resolved 28 December 2018
Resolution: Vessel rep submitted photos showing the screens have been repainted.
Deck/Cargo › Holds/Tanks › Ullage
Issued 13 September 2016
Resolved
Provide repair proposal for wasted forward (Tank 1) ullage tube securing device. Complete repairs after approval.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 14 September 2016
Resolution: Repairs made and verified by pictures via e-mail.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 28 September 2015
Resolved
Repack stuffing tube with missing packing gland or fire retartant material at the tankerman operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 1 October 2015
Resolution: stuffing tube was repacked.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 28 September 2015
Resolved
provide mechanical plug for aft port containment station. 33cfr 155.320
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 28 September 2015
Resolution: placed new mechanical plug in place.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 September 2015
Resolved
sidelight screens needs to comply with 33 cfr 81 (flat black background)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 1 October 2015
Resolution: crew repainted sidelight screens.
Electrical › Electrical Distribution System (service) › Conductor
Issued 28 September 2015
Resolved
remove/terminate excess wire (dead end) in the forward rake.46cfr 111.60.19
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 1 October 2015
Construction/Loadline › Hull › Stringer
Issued 28 September 2015
Resolved
crop and renew #2 void starboardside as marked by attending marine inspector. 46cfr 31.10-15
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 October 2015
Resolved 1 October 2015
Resolution: area cropped and renewed to the satisfaction of MI.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 5 November 2013
Resolved
Ensure proper operation of remote emergency shutdown, to be completed prior to the carriage of cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2013
Resolution: Ensure proper operation of remote emergency shutdown.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 November 2013
Resolved
Replace on deck fire extinguisher bracket with approved type.
Due 5 December 2013
Resolved 6 December 2013
Resolution: Received phone call from port engineer, J. Taylor, that new bracket has been fitted.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 31 October 2011
Resolved
In the Bow Void and Stern Void, install the missing cover screws.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2011
Resolution: repaired while onboard.
Construction/Loadline › Structures › Air Pipe
Issued 31 October 2011
Resolved
The Bow Void vent pipe is holed. Crop and renew to original scantling. Temporary repair is permitted.
Due 5 December 2013
Resolved 27 February 2013
Resolution: Vent pipe was properly repaired.
Construction/Loadline › Hull › Girder
Issued 31 October 2011
Resolved
In the Bow Void, in way of FR. 2, Port side, crop and renew 36 inches of the 8 in x 11.5# channel.
Due 5 December 2013
Resolved 27 February 2013
Resolution: Witnessed satisfactory repair of channel.
Construction/Loadline › Hull › Stiffener
Issued 31 October 2011
Resolved
In the Bow Void, in way of FR. 2, crop and renew the #11 port bottom longitudinal, 36 in. x 4 in. x 3 in. x 5/16 in.
Condition: Damaged By Earlier Event
Due 5 December 2013
Resolved 27 February 2013
Resolution: Witnessed proper repair of bottom longitudinal.
Construction/Loadline › Hull › Stiffener
Issued 31 October 2011
Resolved
In the Stern Void, port side, in way of the stern log, complete the missing 45 inches of weld.
Condition: Improper Installation
Due 5 December 2013
Resolved 27 February 2013
Resolution: Witnessed proper repair of stern void.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 February 2008
Resolved
Crop and renew the fwd cargo tank transverse bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 25 February 2008
Resolution: Bulkhead replaced. Air test Sat.
Construction/Loadline › Structures › Rake
Issued 27 December 2007
Resolved
Renew port and stbd bow rake void hatch covers NLT complletion of the 2008 drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 November 2008
Resolution: Port and Stbd manhole rings and lids renewed.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 27 December 2007
Resolved
Provide gauging report for the thin and wasted areas on # 1cargo tank top fwd bulhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 26 March 2008
Resolution: Report was provide and the bulkhead was wasted.
Deck/Cargo › Ballast › Vents
Issued 27 December 2007
Resolved
Clean ballast tank vent screens as required thru the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 26 March 2008
Resolution: The vents were cleaned
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 December 2007
Resolved
Prohitbit the usage of #3 cargo hose until properly pressure and provide documentary of the same.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 26 March 2008
Resolution: Hoses were tested.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 27 December 2007
Resolved
Provide a list of the spill kit equipment and ensure all items are onboard.
Action required: 705 - Other - as specified
Due 27 January 2008
Resolved 26 March 2008
Resolution: Spill kit was provided.
Construction/Loadline › Hull › Weld
Issued 20 October 2006
Resolved
Starboard side Void #1, in way of the deck to cargo tank plate joint, there is a pin hole leak. Grind / gouge and reweld.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2006
Resolved 24 October 2006
Resolution: Repair satisfactory.
Construction/Loadline › Hull › Weld
Issued 20 October 2006
Resolved
Starboard side Void #4, in way of the deck to cargo tank plate joint, there is a pin hole leak. Grind / gouge and reweld.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2006
Resolved 24 October 2006
Resolution: Repair satisfactory.
Construction/Loadline › Hull › Weld
Issued 20 October 2006
Resolved
Port side Void #4, in way of the deck to cargo tank plate joint, there is a pin hole leak. Grind / gouge and reweld.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2006
Resolved 24 October 2006
Resolution: Repair satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 December 2004
Resolved
Properly install the electrical wiring for the port and starboard running lights and centerline amber flashing light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 December 2004
Resolved
Install a properly operable marine bracket for the forward CO2 hand portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Due 30 December 2004
Resolved 17 December 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 December 2004
Resolved
Renew the broken window in the doghouse with a safety glass.
Condition: Improper/Lack of Maintenance
Due 30 December 2004
Resolved 17 December 2004
Construction/Loadline › Structures
Issued 24 January 2003
Resolved
GOUGE OR GRIND THE WELD IN WAY OF THE PIN HOLE LEAKS, PORT AND STBD SIDES, IN WAY OF FR. 9 AND THE DECK OF THE CARGO TANK / VOID #4. REWELD AFTER GOUGING / GRINDING. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 February 2003
Resolved 18 February 2003
Resolution: COMPLETED.
Construction/Loadline › Structures
Issued 24 January 2003
Resolved
AFTER WELD REPAIRS, CONDUCT A DYE CHECK OF THE REPAIRED AREAS. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Due 15 February 2003
Resolved 18 February 2003
Resolution: SATISFACTORY TEST.
Construction/Loadline
Issued 24 January 2003
Resolved
NO CARGO IS PERMITTED TO BE CARRIED IN TANK #4 UNTIL PERMANENT REPAIRS ARE COMPLETED.
Due 15 February 2003
Resolved 18 February 2003
Deck/Cargo › Holds/Tanks
Issued 23 January 2003
Resolved
Make permanent repairs to the cargo leak in way of port side of #4 void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2003
Resolved 24 January 2003
Resolution: REISSUED CG-835 FOR PERMANENT REPAIRS.
Construction/Loadline › Hull
Issued 22 January 2003
Resolved
Conduct a damage survey of the barge underwater hull and internals. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2003
Resolved 24 January 2003
Resolution: NO DAMAGE NOTED AFTER INTERNAL EXAM.
Construction/Loadline
Issued 31 October 2001
Resolved
Make permanent repairs to cargo tank tops located in void #1 STRBD and #4 Port and STRBD. Provide affidavit attesting to cargo tank integrity after repairs are made.
Condition: Unknown
Due 31 October 2001
Resolved 31 October 2001