Records from 1993 to 2017. Most recent: inspection, 6 December 2017.
Inspection history · 20
6 December 2017
Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6317503
10 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6049226
9 February 2016
Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808650
3 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808838
25 February 2011
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3949719
9 October 2008
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3341295
3 October 2007
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3072310
8 July 2006
ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2705517
4 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2706500
6 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2351114
4 May 2005
COC-GAS Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2348903
2 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2359000
31 January 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400140
31 January 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1106981
29 August 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1358549
4 August 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 369071
21 February 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 436307
10 December 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 362826
3 November 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1152204
19 August 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1135800
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 February 2016
Resolved
0715-Detection-Fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The smoke detector located in the engine room workship was covered with a plastic bag and secured with zip ties. 74SOLASII-2/14
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2016
Resolved 11 February 2016
Resolution: Received class report (Lloyd's Register) attesting to on-board training and testing of the fire detection system with satisfactory results.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 February 2016
Resolved
1750-oil/water interface detector- Oily water content meter is inoperable and is unable to be tested. Ship has requested parts to be delivered to New Orleans. MARPOL Annex I 6.4.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2016
Resolved 11 February 2016
Resolution: Received class report (Lloyd's Register) attesting to the replacement of the OWS content meter and successful operation of the same.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 9 February 2016
Resolved
1099-Other(alarm-signals)-Cargo alarm systems involved in cargo transfer should be tested and checked before cargo handling operations begin. The crew was unable to test low pressure alarm on cargo tanks. Vessel did not have testing equipment on board. IGC 18.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 11 December 2017
Resolution: Received class report to clear deficiency.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 February 2016
Resolved
0799-Other(fire fighting equipment)-Fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The Class-A door handle leading to the engine room from accommodations was loose and did not present an equivalent level of fire protection. 74SOLAS(81am)II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 11 December 2017
Resolution: Received class report to clear deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 February 2016
Resolved
1730-oily-water separating equipment- The vessel's IOPP Form A states the vessel has a MEPC 60(33) Oil Content meter and a A.393(X), however the on board manual for the drawing does not accurately reflect the current configuration. The drawings listed in the manual show a three way valve and current configuration does not have this valve. MARPOL Annex I/6.4.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 11 December 2017
Resolution: Received class report to clear deficiency.
Navigation › Piloting/Steering › Swing Meter
Issued 3 May 2005
Resolved
Pilot reported rudder angle indicators not operating properly upon arrival.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2005
Resolution: Unit was serviced and cleaned. Rudder angle indicators were then tested and found to be operating properly.