HAPPY EAGLE

HAPPY EAGLE is a 1992 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in December 2017, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2017. Most recent: inspection, 6 December 2017.

Built
1992
Last inspected
6 December 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9040170
388521
Flag
ISLE OF MAN
Maury page id
psix-388521

Inspections, by type

…with no type recorded2
Years with a record 2 calendar years (2016–2017)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it3733 - Convention (Subpart B), Gross Ton
1197 - Convention (Subpart B), Net Ton
6918 - Displacement, Metric Ton
4512 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 13

Inspection history · 4

6 December 2017 Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6317503
10 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6049226
9 February 2016 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808650
3 February 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808838

Deficiency record · 5

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 February 2016 Resolved
0715-Detection-Fire detection and fire alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. The smoke detector located in the engine room workship was covered with a plastic bag and secured with zip ties. 74SOLASII-2/14
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2016
Resolved 11 February 2016
Resolution: Received class report (Lloyd's Register) attesting to on-board training and testing of the fire detection system with satisfactory results.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 February 2016 Resolved
1750-oil/water interface detector- Oily water content meter is inoperable and is unable to be tested. Ship has requested parts to be delivered to New Orleans. MARPOL Annex I 6.4.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2016
Resolved 11 February 2016
Resolution: Received class report (Lloyd's Register) attesting to the replacement of the OWS content meter and successful operation of the same.
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 9 February 2016 Resolved
1099-Other(alarm-signals)-Cargo alarm systems involved in cargo transfer should be tested and checked before cargo handling operations begin. The crew was unable to test low pressure alarm on cargo tanks. Vessel did not have testing equipment on board. IGC 18.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2016
Resolved 11 December 2017
Resolution: Received class report to clear deficiency.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 February 2016 Resolved
0799-Other(fire fighting equipment)-Fire resistance of doors shall, as far as practicable, be equivalent to that of the division in which they are fitted. The Class-A door handle leading to the engine room from accommodations was loose and did not present an equivalent level of fire protection. 74SOLAS(81am)II-2/47.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 11 December 2017
Resolution: Received class report to clear deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 February 2016 Resolved
1730-oily-water separating equipment- The vessel's IOPP Form A states the vessel has a MEPC 60(33) Oil Content meter and a A.393(X), however the on board manual for the drawing does not accurately reflect the current configuration. The drawings listed in the manual show a three way valve and current configuration does not have this valve. MARPOL Annex I/6.4.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 11 December 2017
Resolution: Received class report to clear deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.