Records from 2004 to 2026. Most recent: inspection, 15 June 2026.
Inspection history · 51
15 June 2026
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8405198
19 May 2026
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8356388
4 March 2026
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8306452
2 December 2025
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8264585
4 September 2025
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8191847
25 June 2025
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8124127
20 March 2025
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8070868
10 December 2024
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8034050
10 June 2024
Hull Examination · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7927173
20 May 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7916065
12 May 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7910713
25 April 2024
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7879111
26 December 2023
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7842539
19 September 2023
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7794294
18 July 2023
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7720637
21 April 2023
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7659087
25 January 2023
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7604907
3 November 2022
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7564177
18 July 2022
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7509747
27 May 2022
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7458246
23 March 2022
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7417105
25 January 2022
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7358589
13 October 2021
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7331661
31 August 2021
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7301385
29 August 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7392200
21 July 2021
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7263715
5 May 2021
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7190007
24 March 2021
Deficiency Check · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7161845
12 March 2021
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7154865
28 January 2021
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7104069
29 October 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7086315
17 September 2020
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7060282
12 May 2020
Periodic Inspection · MTSA Verification · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6951890
22 March 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6930101
31 July 2019
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6768741
25 April 2019
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6670227
22 January 2019
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6613690
29 October 2018
Deficiency Check · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6566916
13 August 2018
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6510548
12 June 2018
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6441897
18 January 2018
In-Service Inspection · Administrative Inspection · MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6339760
20 November 2017
Administrative Inspection · Re-Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6310248
31 August 2017
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6256133
2 August 2017
Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6216301
17 May 2017
Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6144577
25 January 2017
MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6072558
1 November 2016
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6030591
5 August 2016
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5959806
16 May 2016
Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5876090
22 April 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860093
17 April 2016
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5857445
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 23 January 2024
Resolved
Each rudder angle indicator system must have a transmitter at the rudder head that is actuated by movement of the rudder with the angular movements of the rudder transmitted to a remote indicator or indicators. Readings presented from rudder angle indicators on the bridge were inconsistent with readings at the local steering position. Correct during next dry dock period. 46 CFR 113.40-10(a)
Action required: 705 - Other - as specified
Resolved 10 December 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2023
Resolved
Existing arrangements, materials, and facilities previously approved shall be considered satisfactory so long as they meet the minimum requirements of this paragraph and they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. MI's observed sprinkler manifold valves dripping. Repair to the satifaction of the attending MI at next DD.
46CFR76.23-90(a)(1)
Action required: 705 - Other - as specified
Resolved 10 December 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 October 2023
Resolved
It shall be the duty of the master to see that all watertight doors...are in proper operating condition. MIs observed watertight doors #1 and #2 with loose dogs and #4 with a worn gasket.
46CFR78.17-3(a)
Action required: 10 - Deficiency Rectified
Resolved 17 October 2023
Resolution: Vessel rep rectified defs on-scene.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 January 2023
Resolved
The generator set must be shut down automatically upon loss of lubricating oil pressure, overspeed, or operation of a fixed fire extinguishing system in the emergency generator room. While testing the installed CO2 system, the marine inspector witness that the emergency generator failed to shut down. 46 CFR 112.50-1(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2023
Resolved 1 February 2023
Resolution: Witnessed a successful test of emergency generator's ability to shut down upon deployment of CO2.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Marine Inspector (MI) observed the windings on the gear motors and the starboard generator had excessive grease build up. Clean to remove danger of fire.
Cite: 46 CFR 72.03-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 2 December 2022
Resolution: Received satisfactory photo/documentation of cleaned windings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 November 2022
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. MI observed the six (6) pressure valves in the emergency generator room had no record of testing. Test and record accordingly.
Cite: 46 CFR 77.03-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2022
Resolved 2 December 2022
Resolution: Received satisfactory documentation and record of pressure valves.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 April 2022
Resolved
§ 76.10-5 Fire pumps.(a) Vessels must be equipped with independently driven fire pumps in accordance with table 76.10-5(a).
(c) Each pump shall be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approximately 50 p. s. i. Where one or both of these outlets is a 11/2-inch siamese fitting, both branches of the siamese fitting at each such outlet shall be utilized for the purpose of this requirements. (d) Fire pumps shall be fitted on the discharge side with relief valves set to relieve at 25 p. s. i. in excess of the pressure necessary to maintain the requirements of paragraph (c) of this section or 125 p. s. i., whichever is greater. Relief valves may be omitted if the pumps, operating under shutoff conditions, are not capable of developing a pressure exceeding this amount.
Currently the pressure and the relief valve operation is not IAW this CFR cite. Make proper repairs prior to sailing. Contact USCG Inspections SECTOR NOLA when repaired. Deficiency Cleared 28Apr2022.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2022
Resolved 28 April 2022
Resolution: Relief Valve Removed and pressure does not exceed the max of 125 in the CFR, current pressure max is 117 psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 April 2022
Resolved
§ 72.03-5 Fire hazards to be minimized.(a) The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable.
Currently the Bow Thruster engine H/P F/O line to number 5 cylinder is leaking at the engine head. Replace this defective F/O line and contact the USCG inspection at SECTOR NOLA when completed. Vessel not to sail until repaired. Corrected 28Apr2022 Cleared.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2022
Resolved 28 April 2022
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 August 2021
Resolved
Vsl broke away during hurricane IDA went aground. Shall provide damage survey report and transit plan to DD prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 14 September 2021
Resolved 20 September 2021
Resolution: All damage repaired casused by Hurricane IDA and all survey plans and reports have been submitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2021
Resolved
46 CFR 58.05-1 - The arrangement of auxiliary machinery must be at least equivalent to the standards established by ABS. It was reported that vessel's bow thurster failed due to a log stuck in the propellor. Provide technician's report attesting to proper operation of the bow thruster.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2021
Resolution: Received diver's report and engineer's and master's statement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 July 2021
Resolved
46 CFR 58.05-1(a) - The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter.
Vessel representative reported that the vessel's bow thruster again failed, divers confirmed bent propeller due to previous debris casualty.
Conduct proper repairs and provide a technician's report. Operational testing to be conducted with a CG Marine Inspector in attendance, prior to the carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2021
Resolution: Marien Inspector attended vessel and inspected remanufactured motor, gear and installation for bow thruster steering. Inspector witnessed operational test following company's procedure and all found SAT.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 April 2021
Resolved
The CO2 activated door closure for the engine room was being held open by a coat hanger instead of being held open by the CO2 activated closure solenoid. A VERY DANGEROUS issue which was corrected on the spot. This deficiency was issued and cleared during the inspection.
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
Resolution: Door hooked back up properly to the solenoid. Crew instructed on the hazards with this practive.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 April 2021
Resolved
During the testing of the EDG and its automatic starting and power supply system, it malfunctioned and the generator did not come on line. Problem resolved but not the satisfaction of the USCG inspector. Provide a third party electrical evaluation of the problem and supply a report with findings and corrections prior to getting the vessel underway.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2021
Resolved 30 April 2021
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 24 March 2021
Resolved
1. Prior to getting the vessel underway with passengers the vessel must show compliance with 33CFR 26.01 through 26.09 FCC regulations for radio communications after it was reported by pilots communications could not be established. Also to ensure the radio equipment is not at fault a radio tech. will need to examine the ships radios and make a report on their condition. This must be submitted the USCG.
Action required: 10 - Deficiency Rectified
Due 24 April 2021
Resolved 30 March 2021
Resolution: Radio Tech. visited vessel, and submitted report possible erratic radio operations may have been caused by radio antenna whech were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 29 October 2018
Resolved
10" to 12" of accumulated water on the bilge under #2 MDE due to visible leak coming from port shaft seal supply valve sea chest. Provide repair plan and timeline to correct issue.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2018
Resolved 28 November 2018
Resolution: Removed, inspected, and replaced gasket. Tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2018
Resolved
Two foundation bolts on Bow Thruster hydraulic equipment were loose. Make appropriate and permanent adjustment to secure bolts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2018
Resolved 28 November 2018
Resolution: Tighten bolts.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 October 2018
Resolved
No emergency steering instruction in steering room. Provide permanent posted instruction for engineers onboard not familiar with the system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2018
Resolved 28 November 2018
Resolution: Posted steering operation instruction.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 October 2018
Resolved
Vessel does not have an up-to-date drill logs (fire drill, MOB, security). Binders are disorganized and include different vessel's drill report. No PVA onboard during inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2018
Resolved 28 November 2018
Resolution: Updated logs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 August 2018
Resolved
Sprinklers above rescue boat are not operational. Clean and test sprinklers to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2018
Resolved 26 September 2018
Resolution: Witnessed satisfactory operation of sprinklers above the rescue boat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2018
Resolved
Securely fasten cable runs with metalic fasteners throughout engine and fuel compartments.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2018
Resolved 26 September 2018
Resolution: Inspected and verified metal ties were used for these cable runs.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 12 June 2018
Resolved
F/O transfer hose on board SR# 10825515-1 does not match any hose record on board. Remove hose or place documentation on board.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 27 June 2018
Operations/Management › Drills/Instruction › Fire
Issued 12 June 2018
Resolved
Drill log shows SSMCP and Fire drills conducted by both shifts on 6/3/18 but only one corrosponding drill sheet could be found. Find and log second drill sheet.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 27 June 2018
Operations/Management › Drills/Instruction › Fire
Issued 12 June 2018
Resolved
The drill log folder is in sad shape and requires attention drill logs falling out an d not secure. Fix same.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 27 June 2018
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 June 2018
Resolved
The pilot house alarm panel malfunctions when the test light is pushed all lamps go out instead of on for testing. Repair same.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 27 June 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 June 2018
Resolved
The secondary anchor light is not operating. Correct same.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 27 June 2018
Documentation › Logs/Records › Maneuvering Performance Test Results
Issued 12 June 2018
Resolved
Currently on board PMS schedule not being followed or logged correctly. Correct this issue and schedule a complete automation test for the entire vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2018
Resolved 25 April 2019
Fire Fighting › Fire Pumps › Pressure
Issued 24 January 2018
Resolved
Fire pump not taking suction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 24 January 2018
Resolution: Installed new sea chest vent.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 January 2018
Resolved
Light not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 24 January 2018
Resolution: Battery replaced.
Stability › Watertight Integrity › General
Issued 18 January 2018
Resolved
Escape hatch to main deck not watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2018
Resolved 24 January 2018
Resolution: New gastket installed and hose tested.
Lifesaving › Lifefloat › Markings
Issued 17 May 2017
Resolved
Make with number of persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 22 May 2017
Resolution: Life float has been stenciled
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 May 2017
Resolved
3 E-light not working on the 01 deck. Fix prior to carring passengers on the 01 deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: corrected
Engineering › Bilge Water Management System › Piping
Issued 17 May 2017
Resolved
Replace threaded flange on bilge piping. current one is pitted thrrough 50% of the flange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 2 August 2017
Resolution: flange replaced
Stability › Watertight Integrity › General
Issued 17 May 2017
Resolved
Water tight door indicater lights are on when the door is closed instead of being on when the door is oper as required by 46 CFR 170.255(e)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 2 August 2017
Resolution: Corrected
Electrical › Electric Generation Source (service) › Generator
Issued 17 May 2017
Resolved
Double nut or nyloc nut needed on foundation bolts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 22 May 2017
Resolution: Installed
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 17 May 2017
Resolved
Clean or replace clogged flame screen on oily-water tank vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 22 May 2017
Resolution: Cleaned
Lifesaving › Lifejacket/PFD (Type III) › Condition
Issued 25 January 2017
Resolved
Replace 26 child lifejackets throughout vessel. Current lifejacets were deteriorated.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: Lifejackets were replaced on the spot.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 25 January 2017
Resolved
Replace 2 emergency lights on the car deck.
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 25 January 2017
Resolution: Emergency lights were replaced on the spot.
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 25 January 2017
Resolved
Replace/Repair stbd solenoid for stbd SSDG that adjusts the governor speed and provide engineer's statement of satisfactory operation/installation.
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 9 February 2017
Resolution: Received technician's report to satisfaction of USCG Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 22 April 2016
Resolved
Throttle control failed on stbd engine. Repair to the satisfaction of Marine Inspector. Provide technicians report.
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 22 April 2016
Resolution: All requirements met. Electrician rewired throttle control to have its own independent power source.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 17 April 2016
Resolved
Provide technician's report to secnola attesting to damage and repair. Prior to sailing.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2016
Resolved 18 April 2016
Resolution: Received tech reports stating all test showed no problems