Inspection history · 61
9 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8308144
12 September 2025
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8233145
6 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8203885
30 May 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8148202
13 September 2024
TPO Audit · Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8004235
21 August 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7991055
17 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7866800
25 January 2024
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7855627
16 September 2023
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7808151
17 May 2022
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7452740
4 May 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7453806
21 March 2022
Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7415485
20 March 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7443823
2 January 2022
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 7374851
13 November 2020
Initial Certification · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7120675
14 October 2019
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6834510
14 October 2019
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6834845
5 October 2019
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6836673
22 July 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6759277
15 March 2019
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6648411
26 June 2018
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6457769
7 February 2016
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5817045
27 April 2014
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4847301
29 January 2013
Marine Casualty Follow Up · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4537400
3 March 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3956429
12 May 2010
Spot Check (Safety)
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3737568
14 December 2008
Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3379555
11 February 2007
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2875984
19 January 2007
Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2858726
15 December 2006
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2841228
14 November 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2822017
13 September 2006
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2777249
8 January 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 53048
18 July 2000
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 132953
27 June 2000
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 279925
14 April 2000
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 276915
19 February 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 88849
17 November 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766475
7 November 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 199093
12 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 674754
12 August 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770973
31 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 199082
31 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 199087
31 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 221477
10 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 179062
17 July 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756896
13 July 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 199080
14 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9419
3 January 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 54798
7 September 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 18170
26 June 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 392797
23 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 31249
29 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 11386
10 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70832
23 January 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 26939
7 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 371225
25 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 666332
19 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 666333
17 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 116779
17 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 117504
4 February 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 92240
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2025
Resolved
Stb Gen
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2025
Resolved 16 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 March 2022
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this sub-chapter and other applicable laws and regulations at all times. The vessel suffered a steering casualty while underway. Make repairs and prove proper operation to the satisfaction of a USCG Marine Inspector prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 February 2021
Resolved
The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician. PE letter on file is dated February 21, 2007. Own / operator informed MI that fire-detection system has been updated / replaced after 2007. Prove to the attending Coast Guard marine inspector that the fire detention system was replaced in kind or provide new professional engineer letter for current system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2021
Resolved 11 February 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Record of inspection
Issued 8 February 2021
Resolved
The results of the inspections required by 33 CFR 164.76 (Towline and terminal gear for towing alongside and pushing ahead) must be documented in the TVR, official logbook. TVR did not have recordkeeping for towing gear.
Illustrate to the attending Coast Guard marine inspector of how future records will be recorded
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2021
Resolved 11 February 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 November 2020
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. First aid kits located in galley and on bridge have expired medicine. Prove to the attending Coast Guard marine inspection that first aid kits have non-expired medicine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2021
Resolved 12 February 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 October 2019
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure all bilges and voids are kept free from accumulation of combustible and flammable materials and liquids. Vessel's bilges have not been proactively maintained and are filled with combustible/flammable materials causing a hazardous condition on board. Remove oil/fuel from bilges.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2019
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Both (2) ship service diesel generators have not been proactively maintained causing the windings to be heavily oiled causing a fire hazard. Clean oil from both generator electrical windings. This must be completed before energizing either generator.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 October 2019
Resolved
Prove proper operation of the emergency fuel shut offs.
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2019
Resolved
Electrical systems and equipment must function properly and minimize system failures, fire, and shock. Loose opened ended electrical cables/wires were found in the starboard side generator space, engine room and main deck forward storage locker. Remove all loose open ended
wires and cable through out the entire vessel.
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 24 October 2019
Resolved
All vessel equipment must be used in accordance with the manufacturer's recommended practice and in a manner that minimizes risk of injury or death. The vessels hot water heater pressure/temperature safety device was leaking showing signs of failure causing a hazardous condition. Replace the hot water heater safety device in accordance with the manufacturer's recommendation.
Action required: 30 - Ship detained
Due 24 October 2019
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 October 2019
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery space. Main diesel engine(s), reduction gears (02) and ship service diesel generators (02) leak excessively causing oil and fuel accumulation in the engine room bilges. Prove to the attending USCG Marine Inspector the vessels machinery and piping have been properly maintained to prevent leakage.
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2019
Resolved
Means must be provided for closing, in case of fire, each ventilator, and annular space around funnels and other openings into such spaces. The engine room and generator spaces have not been pro-actively maintained causing a serious risk of fire. The engine room and generator spaces have no means of closing of ventilation
in a fire emergency. Provide closures for all ventilation and openings into the engine room and generator spaces.
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2019
Resolved
Machinery systems must be designed and maintained to provide safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Machinery and piping system valves have not been proactively maintained and are missing handles throughout machinery spaces preventing the opening or closing in an emergency situation. Prove to the attending USCG Marine Inspector all machinery and system valves are properly fitted with handles.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 October 2019
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists. The installed bilge high level float(s) are not fixed to the bilge and would rise with the water in the bilge. Prove to the attending USCG Marine Inspector all high bilge level floats/alarms are installed correctly and have a visual/audio alarm at the operating station.
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2019
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Type 1 life jackets on board have not been proactively maintained, jackets were found to be heavily soiled and not orange in color. Prove that all life jackets on board meet the requirements of 46 CFR 141.300.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2019
Resolved
All pressure vessels must have the max allowable working pressure (MAWP) indicated by a stamp, nameplate, or other means visible by the crew. The pressure vessels (02) on board neither have a nameplate or markings of the MAWP. The relief valves(RV) have not been tested or verified in accordance with 46 CFR 143.245. The markings and set points on the RV have been painted over and/or are not legible. Provide documentation proving the MAWP of the pressure vessel(s) by a professional engineer or install a new pressure vessel(s) in accordance with 46 CFR 143.545. Provide new R/V's and prove testing in accordance with 46 CFR 143.245.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 24 October 2019
Resolved
The owner or managing operator must implement a health and safety plan ensuring that all persons on board the towing vessel comply with the plan. The owner or the managing operator shall implement a health and safety plan in accordance with 46 CFR 140.500, provide a copy of the plan to the local inspection office for review, and make the vessel available for a marine inspector to verify the plan has been implemented.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2019
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 October 2019
Resolved
Systems must be designed and maintained to provide safety of persons on board. Numerous incandescent lighting fixtures are missing covers. Provide covers for all lighting fixtures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 October 2019
Resolved
Fixed fire extinguishing systems required by 46 CFR Part 142 (Sub M) must be approved by the Commandant (CG-ENG). A towing vessel on a rivers route must be equipped with either an approved 160-B semi-portable fire extinguisher or a fixed fire extinguishing system that is properly installed and does not pose a risk to the crew. The vessels fixed fire extinguishing was installed incorrectly. The 600 pound fixed extinguishing system was installed without control/stop valves, manifold discharge piping protection and discharge indicator. System was designed with single pull automatic actuation with heat activation devices (HADs), pressure switches that were not wired to shut down ventilation and/or equipment. Pressure switches and siren were both piped in after the 30 second carbon dioxide (CO2) actuated time delay posing a serious risk to the crew being exposed to CO2. Owner, operator and/or Master must provide plans to prove conformity of the fixed fire suppression system to the regulation or remove the system to prevent accidental discharge and provide a 160-B semi portable fire extinguisher. All to the satisfaction of the attending USCG Marine Inspector. 46 CFR 142.215 / 46 CFR 142.315 / 33 CFR 160.215 Code 30.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 8 February 2021
Resolution: 835V cleared to the satisfaction of the marine inspector. Components meet Subchapter M regulations.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 October 2019
Resolved
The vessel suffered a loss of power do to both generators shutting down by cause of water in the fuel. Vessel crew found 10 inches of water in the #3 port storage tank in which was used to supply fuel to the #2 port day tank. Crew suspects a pin hole in the #3 port fuel storage tank. Vessel is to proceed to Mikes shipyard Wood river, IL, for permanent repairs. Prove proper operation of both generators and main engines. Complete to the satisfaction of an attending USCG Marine Inspector. 46 CFR 140.205
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2019
Resolution: The deficincy was cleared to the satisfaction of the attending CG Marine Inspector.