Records from 1985 to 2019. Most recent: inspection, 19 September 2019.
Inspection history · 60
19 September 2019
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6816822
5 March 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6366002
15 April 2016
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5854915
4 May 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1068294
9 April 2001
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376422
30 December 2000
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1393585
26 December 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 62298
26 October 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 61515
13 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282926
21 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 280232
11 May 2000
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 820458
6 May 2000
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 818046
5 May 2000
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 158279
22 February 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1046563
25 October 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 770950
12 October 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 43074
12 October 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 211543
4 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 450869
30 December 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459462
4 December 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 116801
16 January 1998
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1111898
13 February 1997
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1106890
9 September 1996
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1374732
7 September 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 18170
3 December 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 457847
27 September 1995
Examination of Repairs · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355448
8 July 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 520479
7 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 129975
2 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 65143
8 December 1994
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 832839
15 September 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 869978
8 September 1994
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1178010
15 May 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 517722
19 October 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370720
12 January 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1138254
30 November 1992
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 520508
2 May 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 506711
23 December 1991
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1269480
9 December 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 457934
4 December 1991
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 941899
13 October 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 518311
3 December 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1213877
8 November 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 483209
12 August 1990
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 902596
22 March 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 522567
8 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 466366
19 December 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901942
24 November 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 914057
24 February 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890948
30 January 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1339331
23 December 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 887087
22 November 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 478632
2 May 1988
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1347656
28 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 512659
16 March 1988
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1292798
19 February 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1022902
30 January 1987
COI Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1010909
5 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 457478
26 March 1986
COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1304820
4 April 1985
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 981245
Construction/Loadline
Issued 9 April 2001
No resolution recorded
WELD ALL LEAKING AND SPLIT LAP JOINTS ON BTTOM PLATING ALONG BILGE KNUCKLE.A PPROX 8 TO 10 TON PORT SIDE AND 6 TO 8 ON STBD SIDE. PRIOR TO PLACING VESSEL BACK IN THE WATER.
Condition: Unknown
Due 9 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 April 2001
No resolution recorded
VESSEL IS RESTRICTED FROM DOING ANY CARGO OPERATIONS, LOADING OR OFFLOADINGUNTIL ALL 835 REQUIREMENTS ISSUED THIS DATE HAVE BEEN SATISFIED.
Condition: Unknown
Due 9 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 April 2001
No resolution recorded
PROVIDE COMPLETE SET OF GAUGE READINGS FRO ENTIRE HULL, ALL READINGS TO BE TAKEN IN PITS. HAVE CG INSPECTOR PRESENT FOR READINGS TAKEN. PROVIDE REPAIR PROPOSAL FOR RESULTS. COMPLETE CREDIT DRY-DOCKING.
Condition: Unknown
Due 9 April 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 9 April 2001
No resolution recorded
PROVIDE COMPLETE SET OF GAUGE READINGS FOR CARGO TANK TOP IN WAY OF HEAVILYPITTED AREAS. HAVE CG INSPECTOR PRESENT FOR GAUGE READINGS. PROVIDE REPAIR PROPOSAL FOR REPAIRS REQUIRED. COMPLETE CREDIT CARGO TANK INTERNAL EXAMINATION.
Condition: Unknown
Due 9 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 April 2001
No resolution recorded
SURVEY ALL INTERNAL STRUCTURE MEMBERS PROVIDE PROPOSAL FOR REPAIRS TO INTERNAL STRUCTURE. COMPLETE INTERNAL STRUCTURAL EXAMINATION PRIOR TO PLACING VESSEL BACK IN SERVICE.
Condition: Unknown
Due 9 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 9 April 2001
No resolution recorded
VESSEL IS NOT PERMITTED TO LEAVE THE NEW ORLEANS INSPECTION ZONE UNTIL PROPOSALS SUBMITTED. CALL WEST INSPECTION DETAIL AT [phone withheld], OR 504 733-1837 IF VESSEL IS TO BE MOVED FROM NOLA ZONE.
Condition: Unknown
Due 9 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 30 December 2000
Resolved
Prior to loading cargo, make available all wing voids for examination. On 30DEC00, vessel was drafting 9 ft & 5 ft of water was observed in #1 & #2 voids. Verticle side cord, diagonal, & floor frame damage observed throughout most wing voids.
Condition: Unknown
Due 30 December 2000
Resolved 30 December 2000
Construction/Loadline
Issued 30 December 2000
Resolved
Vessel may proceed to Muskogee, OK to discharge cargo. Maintain salvage pump on board barge. Check voids 1 & 2 hourly for flooding. No loading ofcargo until leak(s) is identified & repaired to the satisfaction of the cognizant OCMI. Provide location of where repairs will be carried out.
Condition: Unknown
Due 30 December 2000
Resolved 30 December 2000
Deck/Cargo
Issued 30 December 2000
Resolved
Prior to loading cargo, make available for inspection all 8 PV valves. On 30DEC00, all 8 PV valves were heavily coated with cargo residues rendering them inoperable.
Condition: Unknown
Due 30 December 2000
Resolved 30 December 2000
Construction/Loadline
Issued 6 May 2000
Resolved
PRIOR TO NEXT ONLOAD OF CARGO, MAKE PERMENANT REPAIRS TO PORT SIDE, SIDE SHELL AND BILGE KNUCKLE IN THE BOW RAKE COMPARTMENT.
Condition: Unknown
Due 6 May 2000
Resolved 6 May 2000
Construction/Loadline
Issued 4 December 1991
Resolved
PRIOR TO 10JAN91 GAS FREE AND PRESENT #1PORT WING VOID FOR INTERNAL EXAMINATION IN WAY OF CARGO TANK REPAIRS CONDUCTED 04DEC91, LOCATED BETWEEN#3 AND 4 CARGO TANK VERTICAL SIDE FRAMES, EXAMINE CLOSELY FIRST FLOOR AFT OF #3 VERTICAL AT CARGO TANK BOTTOM.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Construction/Loadline
Issued 4 December 1991
Resolved
PRIOR TO 10JAN91, CROP AND RENEW TO ORIGINAL, 2'X6' LOWER #2 STARBOARD WINGVOID AFT BULKHEAD.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Construction/Loadline
Issued 4 December 1991
Resolved
PRIOR TO 10JAN91, CROP AND RENEW TO ORIGINAL, 6 FLOOR FRAMES AND BILGE BRACKETS IN #1 STARBOARD WING VOID, BETWEEN #3 AND 4 CARGO TANK VERTICALS; ALSO CROP AND RENEW TO ORIGINAL, LOWER 36" OF #3 AND 4 CARGO TANK SIDE VERTICALS
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Deck/Cargo
Issued 24 November 1989
Resolved
PRIOR TO OPERATION OF THE THERMAL FLUID HEATER, PROVE OPERATION TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 November 1989
Resolved 24 November 1989
Construction/Loadline
Issued 23 December 1988
Resolved
MAKE TEMPORARY REPAIRS TO A 3 FT BY 2 IN FRACTURE IN THE WELD IN THE STARBOARD BOW CORNER WRAPPER AT THE DECK LINE. MAKE PERMANENT REPAIRS NLT 23 JAN 89 TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR
Condition: Unknown
Due 23 December 1988
Resolved 23 December 1988
Deck/Cargo
Issued 23 December 1988
Resolved
CONDUCT AN INSPECTION AND OPERATE THERMAL FLUID HEATER IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR IN ACCORDANCE WITH 46 CFR 61.30-15 AND 46 CFR 61.30-20. THERMAL FLUID HEATER IS TO REMAIN IN A DISABLED CONDITION UNTIL INSPECTION IS CONDUCTED.
Condition: Unknown
Due 23 December 1988
Resolved 23 December 1988