Records from 1993 to 2018. Most recent: inspection, 5 March 2018.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNASHVILLE BRIDGE CO. · NASHVILLE, TN, UNITED STATES · built 1993
Hull materialSteel
PropulsionUnknown
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 46
5 March 2018
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6366002
28 February 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4253005
6 April 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3710563
24 March 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3439189
4 April 2008
Administrative Inspection · Annual Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3175888
8 March 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2884380
23 August 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2757148
19 July 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2756439
25 January 2006
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2572862
15 February 2005
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2293164
2 February 2005
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2285036
8 September 2004
Periodic Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2190187
17 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1966236
27 June 2003
Hull Examination · Internal Structural Exam · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1828175
31 March 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1771048
20 February 2003
Annual Inspection · Drydock Extension
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1746837
4 February 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1483818
2 July 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 513182
24 March 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1060896
22 February 2001
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1415551
10 April 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 816949
22 September 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 534021
1 April 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 501192
15 March 1999
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 805529
29 January 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 469851
26 March 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408080
18 June 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 776666
28 April 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1106200
17 April 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421302
31 October 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1427276
16 April 1996
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1079896
9 March 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 165750
8 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 535475
13 July 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1182404
27 April 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457262
15 February 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 375330
31 December 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 22888
23 December 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 16549
6 September 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 491660
11 July 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 481192
9 May 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442139
11 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 854671
9 February 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 480105
12 December 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159936
14 June 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 843346
18 May 1993
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 832899
Deck/Cargo › Cargo Heating › General
Issued 25 January 2006
Resolved
Prove proper operation of all alarms on thermal fluid heater as required by 46 CFR 61.30
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 7 February 2006
Resolution: All alarms and shutdowns for the thermal fluid heater operated properly.
Deck/Cargo › Cargo Heating › General
Issued 25 January 2006
Resolved
Provide and install light bulbs for control panel lights.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 7 February 2006
Resolution: The light bulb on the control panel for the thermal fluid heater has been replaced.
Engineering › Fuel Oil Service System › Filter
Issued 25 January 2006
Resolved
Prove F/O filters are marine grade.
Action required: 705 - Other - as specified
Due 24 February 2006
Resolved 7 February 2006
Resolution: Documentation from the manufacturer proves the F/O filters are marine grade.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 2 February 2005
Resolved
Prior to operating vapor control system, prove proper operation of vapor control system overfill alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 February 2005
Resolution: tested high level alarms with specific audio and visual alarms at 95% and 98%.
Engineering › Fuel Oil Service System › Filter
Issued 2 February 2005
Resolved
Install approved fuel filter drain plug and flame guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 16 February 2005
Resolution: Drain plug and flame guard were properly installed on fuel filter.
Engineering
Issued 22 February 2001
Resolved
PROVE PROPER OPERATION OF THERMAL FLUID HEATER SAFETIES AND ALARMS PRIOR TOOPERATING HEATER.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Deck/Cargo
Issued 17 April 1997
Resolved
DEMONSTRATE COMPLIANCE WITH BENZENE MONITORING PROGRAM PRIOR TO LOADING CARGOES WITH GREATER THAN 0.5% BENZENE CONTENT.
Condition: Unknown
Due 29 April 1997
Resolved 28 April 1997