Records from 1996 to 2026. Most recent: inspection, 29 January 2026.
Documentation record
Registered dimensions (L × B × D)96.0 ft × 38.0 ft × 18.0 ft
Registered tonnagegross 199 / net 135
ITC dimensions (L × B × D)96.0 ft × 38.0 ft × 18.0 ft
ITC tonnagegross 374 / net 112
BuilderLEEVAC SHIPYARDS INC · JENNINGS, LA, UNITED STATES · built 1996
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, charter, Registry
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it374 - Convention (Subpart B), Gross Ton
199 - Regulatory (Subpart C or D), Gross Ton
112 - Convention (Subpart B), Net Ton
135 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 32
29 January 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8303209
11 April 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7899569
8 June 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7709614
10 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7366082
21 May 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7202757
24 September 2020
Administrative Inspection · Deficiency Check · DAPI Audit · Initial Certification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7065242
28 May 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6963275
4 April 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939671
17 March 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6650863
29 March 2018
Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6381548
26 June 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333382
10 August 2014
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5013715
22 August 2013
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4710793
29 March 2013
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4561325
6 March 2013
MARPOL · MTSA Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4496078
1 September 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4433375
15 April 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3987597
11 February 2011
MTSA Verification · MARPOL · Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3944861
12 July 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3796339
25 March 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3814869
14 July 2009
Annual Inspection · MTSA Verification
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3534756
23 December 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3386692
2 July 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3255017
9 February 2006
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2582671
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957778
27 March 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1764057
25 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1651969
19 April 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 90592
24 November 1998
Uninspected Towing Vessel
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 810148
15 October 1998
Uninspected Towing Vessel
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 809423
8 June 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 91704
10 September 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 97401
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel lost propulsion during operations due to a generator failure.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2026
Resolution: Received ABS Class Report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 October 2020
Resolved
Essential Systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. In accordance with Table 46 CFR 143.245(b) essential systems required to be tested at least once every three months. The fixed bilge system for emergency dewatering could not be tested and proper operation could not be verified. Additionally, there was not a record that the bilge system had previously been tested. Prove proper operation of Bilge system to the satisfaction of attending Marine Inspector.
46 CFR 143.245(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 4 December 2020
Resolution: A successful tests of the bilge suction system was completed. Demonstrated operability of fixed bilge pump and associated fixed piping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 September 2020
Resolved
Each lifebuoy on a towing vessel must be approved under approval series 160.050 or 160.150. The grab line shall be 3/8 inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab lines on the port and starboard life buoys located outside of the pilot house were found to be deteriorated which reduces the breaking strength. Grab lines to be replaced to the satisfaction of the attending marine inspector.
46 CFR 141.360(b)(1).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 10 November 2020
Resolution: Grab lines replaced with new line.