MAURY USCG vessel records Sign in
← All vessels

STOLT INNOVATION

STOLT INNOVATION is a 1996 tank ship. The Coast Guard has recorded 58 inspections since 1996, most recently in August 2025, along with 5 deficiencies and 8 operational controls.

Records from 1996 to 2025. Most recent: operational control imposed, 11 August 2025.

Built
1996
Last inspected
11 August 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9102069 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
441831
Flag
LIBERIA
—
Maury page id
psix-441831

Inspections, by type

…with no type recorded18
Years with a record 22 calendar years (1996–2025)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it36876 - Dead Weight, Metric Ton
49775 - Displacement, Metric Ton
24846 - Convention (Subpart B), Gross Ton
12146 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIRBY 27712 Tank Barge · MISLE 639516 · 14 March 2014 · activity 4816693KIRBY 27720 Tank Barge · MISLE 713861 · 14 March 2014 · activity 4816693GENIUS STAR VII Freight Ship · MISLE 872890 · 14 March 2014 · activity 4816693ROY DEVALL Towing Vessel · MISLE 961668 · 14 March 2014 · activity 4816693GARY REED Towing Vessel · MISLE 1225835 · 14 March 2014 · activity 4816693

Inspection history · 58

11 August 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8207295
13 May 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8133220
16 June 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7933403
30 August 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7780785
30 August 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7781190
11 April 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7662790
5 January 2023 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7629183
25 April 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7435951
25 March 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7158051
18 March 2020 PSC C · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6927351
19 December 2019 ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6876844
25 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6649029
17 March 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6643661
8 January 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6331620
30 October 2017 ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6291577
24 March 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6111142
20 January 2017 Ballast Water Examination · ISPS III Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6068935
13 February 2016 ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5810652
14 March 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4816693
25 January 2011 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3932802
22 January 2011 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3930966
5 January 2011 COC-CHEM Renew
Type not classified · Activities Europe · Activity 3907316
22 September 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2784603
13 September 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2777616
29 April 2006 ISPS II Exam · MARPOL Annex V Examination · COC-CHEM Annual · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2636420
30 April 2005 COC-CHEM Renew · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2346245
24 May 2004 MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2077156
4 May 2004 PII Safety Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2136961
13 March 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2024134
2 March 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1751494
27 February 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1759169
14 February 2003 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1744546
24 October 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1697060
21 July 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1650029
18 July 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1650147
15 July 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1648850
20 March 2002 Security Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1495379
15 March 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1493979
7 March 2002 Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1492288
6 March 2002 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1492114
4 March 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1490743
11 November 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295480
6 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295306
3 November 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 295255
31 January 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 286950
31 January 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1059331
1 December 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 435304
13 April 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 117310
6 December 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 444880
1 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423124
1 December 1998 Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415085
14 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58068
13 December 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 411172
13 December 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1116303
4 December 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410776
14 October 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 446698
14 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 398384
14 December 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1095050

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 March 2019 Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITION ON BOARD. PSCO'S NOTED THAT THE NUMBER 1 NITROGEN COMPRESSOR IS LEAKING LUBE OIL FROM THE FILTER BOX INTAKE FLANGE. SOLAS(2001) II-1 REG. 26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 March 2019
Resolution: PSC HOU received DNV GL report attesting that Number 1 nitrogen compressor filter box was changed and confirmed to be leak free by attending surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 22 January 2011 Resolved
Vessel reported that it had an inoperable ODME. Vessel has a letter of dispensation until 19FEB2011.
Due 19 February 2011
Resolved 6 June 2011
Resolution: Recieved Class report attesting to the satisfactory repair and operational testing of the vessels ODME
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 4 May 2004 Resolved
Bearing failure in the scanner motor of the 10cm ARPA. Second ARPA down requsted deviation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2004
Resolution: Recieved tech. report on the 15th of May.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 February 2003 Resolved
Vessel given deviation for inoperable radar.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2003
Resolved 29 March 2003
Resolution: Litton Marine Systems made repairs and forwarded report to CG. Radar working properly.
Lifesaving
Issued 1 December 1998 Resolved
FLAMMABLE MATERIAL STOWED IN "ROPE ROOM" AFT OF "GENERATOR ROOM" WITHOUT PROPER FIRE PROTECTION.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.