GENIUS STAR VII is a 2007 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in July 2025, along with 8 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 8 July 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it16056 - Displacement, Metric Ton 9589 - Convention (Subpart B), Gross Ton 3725 - Convention (Subpart B), Net Ton 12005 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. Vessel's BWMS is inoperable.
33 CFR 151.2025(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 July 2025
Resolution: Legacy def, added as special note as vsl has not returned to US since 2018.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 20 July 2018Resolved
SOLAS74(14)II-2/4.4.3; 17AC; IN SPACES WHERE PENETRATION OF OIL PRODUCTS IS POSSIBLE, THE SURFACE OF INSULATION SHALL BE IMPERVIOUS TO OIL OR OIL VAPOURS. VARIOUS LAGGING ASSOCIATED WITH FUEL OIL SYSTEMS IN THE ENGINE ROOM WERE COVERED WITH FUEL OIL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2018
Resolution: RECIEVED SATISFACTORY CLASS REPORT. DEFICIENCY CLEARED.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 20 July 2018Resolved
SOLAS74(14)II-2/9.4.1.1.5.1; 17AC; THE DOORS SHALL BE SELF-CLOSING AND BE CAPABLE OF CLOSING WITH AN ANGLE OF INCLINATION OF UP TO 3.5 DEGREES OPPOSING CLOSURE. VARIOUS SELF-CLOSING DOORS THROUGHOUT THE SHIP WERE NOT SELF-CLOSING AND HAD MISSING GASKETS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2018
Resolution: RECIEVED SATISFACTORY CLASS REPORT. DEFICIENCY CLEARED.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 July 2018Resolved
SOLAS74(14)II-2/15.2.4.1; 40AC; GENERAL ARRANGEMENTS PLANS SHALL BE PERMANENTLY EXHIBITED FOR THE GUIDANCE OF THE SHIP'S OFFICERS, SHOWING CLEARLY FOR EACH DECK THE CONTROL STATIONS, THE VARIOUS FIRE SECTIONS ENCLOSED BY "A" CLASS DIVISIONS, THE SECTIONS ENCLOSED BY "B" CLASS DEVISIONS TOGETHER WITH THE PARTICULARS OF THE FIRE DETECTION AND FIRE ALARM SYSTEMS. THE SHIP'S FIRE CONTROL PLAN DOES NOT SPECIFIY WHICH "A" CLASS DOORS THROUGHOUT THE SHIP ARE REQUIRED TO BE SELF-CLOSING, ALTHOUGH SOME ARE LABELED AS SELF CLOSING AND HAVE SELF CLOSING DEVICES.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2018
Resolution: Received satisfactory class report
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 20 July 2018Resolved
SOLAS74(14)I/11(A); 40AC; THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE WINCH ASSOCIATED WITH THE ANCHOR SYSTEM WAS LEAKING HYDRAULIC FLUID ONTO THE DECK.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2018
Resolution: Received satisfactory class report
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 20 July 2018Resolved
SOLAS74(14)I-11(A); 40AC; THE CONDITTION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE BALLAST PUMP WAS DISCOVERED TO BE EXCESSIVLEY LEAKING.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2018
Resolution: Received satisfactory class report
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 20 July 2018Resolved
33CFR156.120(C); 40AC; NO PERSON SHALL CONDUCT AN OIL OR HAZARDOUS MATERIAL TRANSFER OPERATION UNLESS: EACH DRAIN AND SCUPPER IS CLOSED BY MECHANICAL MEANS REQUIRED BY 155.310. DRAINS ON ALL CONTAINMENT ON DECK WERE NOT CLOSED BY MECHANICAL MEANS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2018
Resolution: Received satisfactory class report
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 July 2018Resolved
SOLAS74(14)II-2/10.6.3.2; 10C; FLAMMABLE LIQUID LOCKERS SHALL BE PROTECTED BY AN APPROPRIATE FIRE-EXTINGUISHING ARRANGEMENT APPROVED BY THE ADMINISTRATION. PAINT AND OTHER FLAMMABLE LIQUIDS WERE STORED IN A SPACE WITHOUT AN APPROPRIATE FIRE EXTINGUISHING ARRANGMENT.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 21 July 2018
Resolution: Received satisfactory class report
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.